Influence of damage degree of recycled coarse aggregate concrete-filled steel tube columns strengthened with envelope steel jacket under seismic load

被引:0
|
作者
Zhou, Changwen [1 ]
Xu, Chengxiang [2 ]
Han, Yunfei [2 ]
Zhou, Heng [2 ]
Peng, Sheng [3 ,4 ]
Liu, Jialiang [3 ]
Wang, Tianlei [4 ]
机构
[1] Wuhan Bohong Construct Grp Co Ltd, Wuhan Hanyang Municipal Construct Grp Co Ltd, Wuhan, Peoples R China
[2] Wuhan Univ Sci & Technol, Sch Urban Construct, Wuhan 430065, Peoples R China
[3] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[4] Tianjin Chengjian Univ, Tianjin Key Lab Bldg Green Funct Mat, Tianjin, Peoples R China
关键词
Recycled coarse aggregate concrete-filled steel tube column; damage degree; enveloped steel jacket (ESJ); seismic damage model; seismic load; COMPRESSIVE BEHAVIOR; TUBULAR STUB; PERFORMANCE; MODEL;
D O I
10.1080/13467581.2024.2434531
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to discuss the influence of damage degree of recycled coarse aggregate concrete-filled steel tube columns strengthened with envelope steel jacket (ESJ) under seismic load, eight columns were designed and manufactured to simulate seismic loading, with the design of ESJ strengthening after pre-damage and destruct tests under seismic load. This experiment was conducive to accurately evaluating the influence mechanism and synergistic effect of seismic damage degree and recycled coarse aggregate on the hysteresis curve, skeleton curve, ductility performance, energy dissipation performance, and bearing capacity performance of each specimens, and a suitable seismic damage model was proposed. The ductility coefficient is from 3.36 and 4.64, satisfying the requirements of seismic design. The research results indicate that the degree of seismic damage and recycled coarse aggregate are unfavorable to improve the seismic performance of recycled coarse aggregate concrete-filled steel tube columns strengthened with ESJ under seismic load; Taking the ductility coefficient of specimen SEJS-0 as the basic data, specimens SEJS-1 to SEJS-3 and FC-0 to FC-3 increased by 22.02%, 20.24%, 8.33%, 18.15%, 38.10%, 35.71%, and 23.51%, respectively. Under moderate and severe damage, the ductility performance of enveloped steel jacket-strengthened seismic-damaged specimens decreased by 15.47% and 15.18%, respectively, and the reduction amplitude of both was similar. As the degree of seismic damage increases, the value of the ultimate bearing capacity first decreases and then increases. The method of using recycled coarse aggregate to replace half of natural coarse aggregate has certain feasibility in the field of concrete-filled steel tube columns. Recycled coarse aggregate has a significant impact on the bearing capacity of each stage, while the degree of seismic damage only has a greater impact on the ultimate stage. The established seismic damage model for recycled coarse aggregate concrete-filled steel tube columns strengthened with ESJ under seismic load is feasible and can be used for quantitative evaluation of the seismic capacity of such components.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Numerical analysis of recycled aggregate concrete-filled steel tube stub columns
    Xiang, Xingyun
    Cai, C. S.
    Zhao, Renda
    Peng, Hui
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (05) : 717 - 729
  • [12] Seismic Strength and Stiffness for Recycled Aggregate Concrete-Filled Steel Tube Frame
    Zhang, Xianggang
    Yang, Jianhui
    Zhang, Yaozong
    Gao, Xiang
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [13] Seismic behavior analysis of recycled aggregate concrete-filled steel tube column
    Xianggang Z.
    Shuren W.
    Xiang G.
    Yongsheng H.
    Journal of Engineering Science and Technology Review, 2019, 12 (04): : 124 - 126
  • [14] Axial compressive behavior of recycled aggregate concrete-filled square steel tube stub columns strengthened by CFRP
    Liang, Jiongfeng
    Lin, Siqi
    Li, Wei
    Liu, Dawei
    STRUCTURES, 2021, 29 : 1874 - 1881
  • [15] Structural behaviour of recycled aggregate concrete filled steel tube columns strengthened by CFRP
    Dong, J. F.
    Wang, Q. Y.
    Guan, Z. W.
    ENGINEERING STRUCTURES, 2013, 48 : 532 - 542
  • [16] A modified Park-Ang model for seismic damage assessment of recycled aggregate concrete-filled square steel tube columns
    Peng, Sheng
    Wang, Junyu
    Yao, Yingkang
    Min, Tianrun
    Li, Chaoying
    Luo, Le
    Zhu, Yide
    Wen, Xin
    Zhou, Man
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [17] Cyclic performance of recycled aggregate with ferronickel slag concrete-filled steel tube columns
    Xu, Li
    Chen, Jun
    Chen, Hua-Yan
    Luo, Cai-Song
    Syed, Humayun Basha
    STRUCTURES, 2024, 60
  • [18] Damage assessment for seismic response of recycled concrete filled steel tube columns
    Yijie Huang
    Jianzhuang Xiao
    Luming Shen
    Earthquake Engineering and Engineering Vibration, 2016, 15 : 607 - 616
  • [19] Damage assessment for seismic response of recycled concrete filled steel tube columns
    Huang Yijie
    Xiao Jianzhuang
    Shen Luming
    EarthquakeEngineeringandEngineeringVibration, 2016, 15 (03) : 607 - 616
  • [20] Experimental study on the seismic behavior of CFRP-strengthened seismic-damaged recycled aggregate concrete-filled rectangular steel tube frame columns
    Peng, Sheng
    Xiong, Zhou
    JOURNAL OF BUILDING ENGINEERING, 2022, 45