SMART : the closed-loop control system for LAMOST

被引:0
|
作者
Wang, Anzhi [1 ,2 ]
Gan, Zhaoxu [1 ,2 ]
Liu, Yilong [1 ,2 ]
Wang, Jiabin [1 ,2 ]
Yue, Gang [1 ,2 ]
Yan, Yunxiang [1 ,2 ,3 ]
Wang, Shengjia [1 ,2 ]
Yan, Qi [1 ,2 ,4 ,5 ]
Geng, Tao [1 ,2 ]
Wang, Pengfei [3 ]
Chen, Shuang [6 ]
Sun, Weimin [1 ,2 ]
机构
[1] Harbin Engn Univ, Coll Phys & Optoelect Engn, Key Lab Photon Mat & Devices Phys Ocean Applicat, Minist Ind & Informat Technol China, Harbin 150001, Peoples R China
[2] Harbin Engn Univ, Coll Phys & Optoelect Engn, Minist Educ, Key Lab In Fiber Integrated Opt, Harbin 150001, Peoples R China
[3] Harbin Engn Univ, Qingdao Innovat & Dev Ctr, Qingdao 266000, Peoples R China
[4] Harbin Engn Univ, Yantai Res Inst, Yantai 264000, Peoples R China
[5] Harbin Engn Univ, Grad Sch, Yantai 264000, Peoples R China
[6] China Aerodynam Res & Dev Ctr, State Key Lab Aerodynam, Mianyang 621000, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi-target telescopes; aimer; closed-loop control system; LAMOST; fiber positioning;
D O I
10.1117/12.3019967
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The accuracy of fiber positioning is crucial for the observation of multi-target fiber spectral telescopes such as LAMOST (Large Sky Area Multi-Object Fiber Spectroscopy Telescope). Most of the methods used for fiber positioning are open-loop control or semi-closed-loop control, the efficiency cannot meet the requirements of next-generation spectral telescopes. Considering that, this paper proposes a fiber positioning method that can achieve a completely closed loop without blind spots based on SMART (Special-shaped Micro-lens Aimer for Real-time Targeting) and a dual-rotary positioning mechanism. The entire correction process can be described as follows: first, the light intensity obtained by the 6-channel photodetector is stored in a buffer. Then the pulses required for correction are calculated based on the data in the buffer and the correction algorithm by the computer. The running command is then sent to the stepper motor controller using serial communication to drive the stepper motor. After the movement, the program will run again to verify if the correction is done. After selecting a position in the first quadrant, 8 directions were selected to conduct automatic correction experiments after the optical fiber position offset. The experimental results show that the average farthest distance that the method could correct is 600 mu m, and 75.9% positioning accuracy under our closed control method can reach 10 mu m, 94.8% positioning accuracy can reach 20 mu m, 100% positioning accuracy can reach 30 mu m. For corrections within the 500 mu m offset distance, 97.5 % of the correction time is within one minute.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Closed-loop Control in EMR Based on a BI System
    Tao, Min
    Wang, Yu
    Tian, Yu
    Li, Jing-song
    2015 IEEE International Conference on Signal Processing, Communications and Computing (ICSPCC), 2015, : 26 - 29
  • [32] Closed-loop position control system using LAVIEW
    Aaron, KR
    Foster, NL
    Hazel, DP
    Basher, AMH
    IEEE SOUTHEASTCON 2002: PROCEEDINGS, 2002, : 283 - 286
  • [33] UTILIZATION OF A CLOSED-LOOP EMERGENCY CONTROL SYSTEM.
    Barkan, Ya.D.
    Power engineering New York, 1981, 19 (01): : 51 - 57
  • [34] Closed-loop Control System Based on the Trajectory Information
    Wang, Huaiyuan
    Zhang, Baohui
    Yang, Songhao
    Yang, Hao
    Wu, Lihua
    Wang, Qing
    Li, Xiaojun
    Ma, Shiying
    Lin, Junjie
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ELECTRIC AND ELECTRONICS, 2013, : 372 - 375
  • [35] Control of cortical oscillatory frequency by a closed-loop system
    D'Andola, Mattia
    Giulioni, Massimiliano
    Dante, Vittorio
    Del Giudice, Paolo
    Sanchez-Vives, Maria V.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (1)
  • [36] A dual closed-loop control system for mechanical ventilation
    Tehrani F.T.
    Rogers M.
    Lo T.
    Malinowski T.
    Afuwape S.
    Lum M.
    Grundl B.
    Terry M.
    Journal of Clinical Monitoring and Computing, 2004, 18 (2) : 111 - 129
  • [37] Closed-loop structural control with real-time smart sensors
    Linderman, Lauren E.
    Spencer, Billie F., Jr.
    SMART STRUCTURES AND SYSTEMS, 2015, 16 (06) : 1147 - 1167
  • [38] Smart Braid Feedback for the Closed-Loop Control of Soft Robotic Systems
    Felt, Wyatt
    Chin, Khai Yi
    Remy, C. David
    SOFT ROBOTICS, 2017, 4 (03) : 261 - 273
  • [39] Smart in-cylinder pressure sensor for closed-loop combustion control
    Vollberg, Dennis
    Gibson, Peter
    Schultes, Gunter
    Groh, Hans-Werner
    Heinze, Thomas
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2022, 11 (01) : 1 - 13
  • [40] CLOSED-LOOP CONTROL IS COMING
    GILMAN, HD
    GOODMAN, MY
    DEMOYER, R
    RADZIUL, JV
    WATER & WASTES ENGINEERING, 1973, 10 (06): : 42 - 44