Non-enzymatic photoelectrochemical sensors based on rGO/TiO2/Cu-MOFs nanostructures for simultaneous detection of glucose and lactic acid

被引:0
|
作者
Tao, Bairui [1 ]
Guo, Huihui [1 ]
Li, Xiaoqin [1 ]
Miao, Fengjuan [1 ]
Li, Hui [1 ]
机构
[1] Qiqihar Univ, Coll Commun & Elect Engn, Qiqihar 161006, Heilongjiang, Peoples R China
关键词
Photoelectrochemical detection; Non-enzymatic; Glucose sensor; Lactic acid sensor;
D O I
10.1016/j.vacuum.2025.114105
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study reports the preparation of a high-performance rGO/TiO2/Cu-MOFs sensitive electrode through a twostep hydrothermal method. This electrode exhibits low detection limits, high sensitivity, and a straightforward fabrication process. The nanomaterials are uniformly grown on a 1 x 1 cm2 nickel foam substrate, with rGO first coated and then followed by the growth of rod-shaped TiO2 and Cu-MOFs metal particles, forming a threedimensional spatial structure. The micromorphology, chemical composition, and state of the electrode were characterized using TEM, SEM, and other techniques. Its electrochemical performance was tested using an electrochemical workstation. Experimental results indicate that the copper ions in this electrode, due to their different valence states, can achieve highly sensitive detection of glucose and lactic acid, with sensitivities reaching as high as 1195.13 mu A mM-1 cm-2 and 1157.77 mu A mM-1 cm-2, respectively. Additionally, it possesses excellent anti-interference ability, stability, and reproducibility, making it a promising dual-function photoelectrochemical sensor.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Recent Advances in Non-Enzymatic Glucose Sensors Based on Metal and Metal Oxide Nanostructures for Diabetes Management- A Review
    Naikoo, Gowhar A.
    Salim, Hiba
    Hassan, Israr U.
    Awan, Tasbiha
    Arshad, Fareeha
    Pedram, Mona Z.
    Ahmed, Waqar
    Qurashi, Ahsanulhaq
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [42] An Amperometric Non-enzymatic Glucose Sensor by Nickel Hexacyanoferrate Nanoparticles Modified TiO2 Nanotube Arrays
    Yu Shu-Juan
    Zhang Yun-Huai
    Xiao Peng
    Li Xiao-Ling
    Meng Xiao-Qin
    Yang Yan-Nan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (02) : 313 - 316
  • [43] MXene-Embedded Porous Carbon-Based Cu2O Nanocomposites for Non-Enzymatic Glucose Sensors
    Gopal, Tami Selvi
    James, Jaimson T.
    Gunaseelan, Bharath
    Ramesh, Karthikeyan
    Raghavan, Vimala
    Malathi, Christina Josephine A.
    Amarnath, K.
    Kumar, V. Ganesh
    Rajasekaran, Sofia Jennifer
    Pandiaraj, Saravanan
    Muthumareeswaran, M. R.
    Pitchaimuthu, Sudhagar
    Abeykoon, Chamil
    Alodhayb, Abdullah N.
    Grace, Andrews Nirmala
    ACS OMEGA, 2024, 9 (07): : 8448 - 8456
  • [44] Non-enzymatic amperometric glucose sensing on CuO/mesoporous TiO2 modified glassy carbon electrode
    Ali, Muhammad
    Mir, Sadullah
    Ahmed, Safeer
    RSC ADVANCES, 2023, 13 (37) : 26275 - 26286
  • [45] Graphene wrapped Cu2O nanocubes: Non-enzymatic electrochemical sensors for the detection of glucose and hydrogen peroxide with enhanced stability
    Liu, Minmin
    Liu, Ru
    Chen, Wei
    BIOSENSORS & BIOELECTRONICS, 2013, 45 : 206 - 212
  • [46] Development of Cu2O-Cu-ZnO ternary nanocomposites for high-performance photoelectrochemical non-enzymatic glucose sensor
    Miao, Huanran
    Yang, Zhimao
    Lv, Jian
    Kong, Chuncai
    SURFACES AND INTERFACES, 2024, 46
  • [47] Electrochemical Non-Enzymatic Detection of Glucose Based on 3D Electroformed Copper on Ni Foam Nanostructures
    Melinte, Gheorghe
    Cernat, Andreea
    Petica, Aurora
    Lazar, Oana
    Enachescu, Marius
    Anicai, Liana
    Cristea, Cecilia
    MATERIALS, 2020, 13 (12) : 1 - 16
  • [48] CuO/Cu2O nanofibers as electrode materials for non-enzymatic glucose sensors with improved sensitivity
    Lu, Na
    Shao, Changlu
    Li, Xinghua
    Shen, Teng
    Zhang, Mingyi
    Miao, Fujun
    Zhang, Peng
    Zhang, Xin
    Wang, Kexin
    Zhang, Yang
    Liu, Yichun
    RSC ADVANCES, 2014, 4 (59): : 31056 - 31061
  • [49] Enhancing glucose detection: Vanadium-doped TiO2 (V0.07Ti0.93O2) as non-enzymatic biosensor
    Rao, Lavanya
    Bhat, Badekai Ramachandra
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2024, 35 (16)
  • [50] Development of non-enzymatic cholesterol bio-sensor based on TiO2 nanotubes decorated with Cu2O nanoparticles
    Khaliq, Nilem
    Rasheed, Muhammad Asim
    Cha, Gihoon
    Khan, Maaz
    Karim, Shafqat
    Schmuki, Patrik
    Ali, Ghafar
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 302