H-Loop Knotless Double-Row Repair Versus Krackow Repair for Achilles Tendon Rupture: A Biomechanical Study in a Cadaveric Model

被引:0
|
作者
Hou, Jingyi [1 ]
Li, Yuxiang [1 ]
Zheng, Zhenze [1 ]
Long, Yi [1 ]
Zhou, Min [1 ]
Yang, Yitao [1 ]
Yang, Rui [1 ]
机构
[1] Sun Yat sen Univ, Sun Yat sen Mem Hosp, 107 Yan Jiang Rd West, Guangzhou 510120, Guangdong, Peoples R China
基金
美国国家科学基金会;
关键词
Achilles tendon rupture; HLDR; Krackow; knotless; biomechanical study; ROTATOR CUFF REPAIR; SINGLE-ROW; SUTURE; REHABILITATION; STITCH; ELONGATION; STABILITY; INSERTION; FIXATION; NUMBER;
D O I
10.1177/23259671241270350
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Surgery is widely recognized as an effective treatment for Achilles tendon rupture; however, there remains debate regarding the optimal surgical approach. Purpose: To compare the biomechanical properties of 2 techniques, the H-loop knotless double-row (HLDR) suture repair and the Krackow suture repair, for Achilles tendon rupture in a cadaveric model. Study Design: Controlled laboratory study. Methods: Ten matched Achilles tendon specimens from 5 male and 5 female donors were obtained. Each specimen from a matched pair was randomly distributed to 1 of 2 repair groups, the HLDR group or the Krackow group. Tendon elongation was recorded after exposure to 10, 100, 200, 400, 600, 800, and 1000 load cycles. The gap distance after application of a 100-N force, the force needed to produce a 2-mm gap, and the load to failure were measured. All biomechanical properties were compared between the HLDR and Krackow groups using the paired t test. Results: The HLDR group consistently exhibited significantly less elongation than the Krackow group after exposure to the 7 load cycles (P < .01 for all). In addition, the HLDR group exhibited a significantly smaller gap distance after applying a 100-N force (0.30 +/- 0.02 vs 8.10 +/- 0.46 mm for Krackow group), required significantly more force to generate a 2-mm gap (419.68 +/- 39.48 vs 22.29 +/- 3.40 N for the Krackow group), and had a significantly higher ultimate failure load (519.91 +/- 57.29 vs 220.30 +/- 19.27 N for the Krackow group) (P < .01 for all). Conclusion: The study findings demonstrated that the HLDR technique had more advantages compared with the Krackow technique with regard to elongation after different cyclic loadings, gap distance after a 100-N load, force needed to produce a 2-mm gap, and load to failure in a cadaveric model. Clinical Relevance: The HLDR technique could be a viable option for Achilles tendon rupture repair.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Achilles tendon-splitting approach and double-row suture anchor repair for Haglund syndrome
    Guler, Yasin
    Birinci, Murat
    Hakyemez, Omer Serdar
    Buyukdogan, Kadir
    Cacan, Mehmet Akif
    Arslanoglu, Fatih
    Mermerkaya, Musa Ugur
    FOOT AND ANKLE SURGERY, 2021, 27 (04) : 421 - 426
  • [22] Tuberosity Repair in Reverse Total Shoulder Arthroplasty for Fracture Using a Stem-based Double-row Repair: A Cadaveric Biomechanical Study
    Erickson, Brandon J.
    Shishani, Yousef
    Bishop, Meghan E.
    Romeo, Anthony A.
    Lederman, Evan
    Gobezie, Reuben
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (23) : E1059 - E1065
  • [23] The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study
    Meier, Steven W.
    Meier, Jeffrey D.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (11): : 1168 - 1173
  • [24] LATE VERSUS EARLY REPAIR OF ACHILLES-TENDON RUPTURE - CLINICAL AND BIOMECHANICAL EVALUATION
    BOYDEN, EM
    KITAOKA, HB
    CAHALAN, TD
    AN, KN
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 150 - 158
  • [25] Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace A Biomechanical Cadaveric Study
    Rothfeld, Alex
    Pawlak, Amanda
    Liebler, Stephenie A. H.
    Morris, Michael
    Paci, James M.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (05): : 1199 - 1204
  • [26] Achilles tendon repair: Achillon system vs. Krackow suture: An anatomic in vitro biomechanical study
    Huffard, B.
    O'Loughlin, P. F.
    Wright, T.
    Deland, J.
    Kennedy, J. G.
    CLINICAL BIOMECHANICS, 2008, 23 (09) : 1158 - 1164
  • [27] Interlocking horizontal mattress suture versus Kakiuchi technique in repair of Achilles tendon rupture: a biomechanical study
    Guzzini, Matteo
    Lanzetti, Riccardo Maria
    Proietti, Lorenzo
    Mazza, Daniele
    Fabbri, Mattia
    Monaco, Edoardo
    Ferri, Germano
    Ferretti, Andrea
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 18 (03) : 251 - 257
  • [28] Interlocking horizontal mattress suture versus Kakiuchi technique in repair of Achilles tendon rupture: a biomechanical study
    Matteo Guzzini
    Riccardo Maria Lanzetti
    Lorenzo Proietti
    Daniele Mazza
    Mattia Fabbri
    Edoardo Monaco
    Germano Ferri
    Andrea Ferretti
    Journal of Orthopaedics and Traumatology, 2017, 18 : 251 - 257
  • [29] Biomechanical comparison of subscapularis peel and lesser tuberosity osteotomy for double-row subscapularis repair technique in a cadaveric arthroplasty model
    Virk, Mandeep S.
    Aiyash, Saleh S.
    Frank, Rachel M.
    Mellano, Christopher S.
    Shewman, Elizabeth F.
    Wang, Vincent M.
    Romeo, Anthony A.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [30] Biomechanical comparison of subscapularis peel and lesser tuberosity osteotomy for double-row subscapularis repair technique in a cadaveric arthroplasty model
    Mandeep S. Virk
    Saleh S. Aiyash
    Rachel M. Frank
    Christopher S. Mellano
    Elizabeth F. Shewman
    Vincent M. Wang
    Anthony A. Romeo
    Journal of Orthopaedic Surgery and Research, 14