H-Loop Knotless Double-Row Repair Versus Krackow Repair for Achilles Tendon Rupture: A Biomechanical Study in a Cadaveric Model

被引:0
|
作者
Hou, Jingyi [1 ]
Li, Yuxiang [1 ]
Zheng, Zhenze [1 ]
Long, Yi [1 ]
Zhou, Min [1 ]
Yang, Yitao [1 ]
Yang, Rui [1 ]
机构
[1] Sun Yat sen Univ, Sun Yat sen Mem Hosp, 107 Yan Jiang Rd West, Guangzhou 510120, Guangdong, Peoples R China
基金
美国国家科学基金会;
关键词
Achilles tendon rupture; HLDR; Krackow; knotless; biomechanical study; ROTATOR CUFF REPAIR; SINGLE-ROW; SUTURE; REHABILITATION; STITCH; ELONGATION; STABILITY; INSERTION; FIXATION; NUMBER;
D O I
10.1177/23259671241270350
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Surgery is widely recognized as an effective treatment for Achilles tendon rupture; however, there remains debate regarding the optimal surgical approach. Purpose: To compare the biomechanical properties of 2 techniques, the H-loop knotless double-row (HLDR) suture repair and the Krackow suture repair, for Achilles tendon rupture in a cadaveric model. Study Design: Controlled laboratory study. Methods: Ten matched Achilles tendon specimens from 5 male and 5 female donors were obtained. Each specimen from a matched pair was randomly distributed to 1 of 2 repair groups, the HLDR group or the Krackow group. Tendon elongation was recorded after exposure to 10, 100, 200, 400, 600, 800, and 1000 load cycles. The gap distance after application of a 100-N force, the force needed to produce a 2-mm gap, and the load to failure were measured. All biomechanical properties were compared between the HLDR and Krackow groups using the paired t test. Results: The HLDR group consistently exhibited significantly less elongation than the Krackow group after exposure to the 7 load cycles (P < .01 for all). In addition, the HLDR group exhibited a significantly smaller gap distance after applying a 100-N force (0.30 +/- 0.02 vs 8.10 +/- 0.46 mm for Krackow group), required significantly more force to generate a 2-mm gap (419.68 +/- 39.48 vs 22.29 +/- 3.40 N for the Krackow group), and had a significantly higher ultimate failure load (519.91 +/- 57.29 vs 220.30 +/- 19.27 N for the Krackow group) (P < .01 for all). Conclusion: The study findings demonstrated that the HLDR technique had more advantages compared with the Krackow technique with regard to elongation after different cyclic loadings, gap distance after a 100-N load, force needed to produce a 2-mm gap, and load to failure in a cadaveric model. Clinical Relevance: The HLDR technique could be a viable option for Achilles tendon rupture repair.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] H-loop Knotless Double-Row Repair Versus Knotted Suture Bridge for Rotator Cuff Tears A Biomechanical and Histological Study in an Animal Model
    Guo, Jiang
    Long, Yi
    Zhou, Min
    He, Zhang-Hai
    Zeng, Wei-Ke
    Yu, Meng-Lei
    Yamuhanmode, Alike
    Tang, Yi-Yong
    Li, Fang-Qi
    Meng, Ke
    Hou, Jing-Yi
    Yang, Rui
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (07): : 1948 - 1959
  • [2] Single-row Versus Double-row Repair of the Distal Achilles Tendon: A Biomechanical Comparison
    Pilson, Holly
    Brown, Philip
    Stitzel, Joel
    Scott, Aaron
    JOURNAL OF FOOT & ANKLE SURGERY, 2012, 51 (06): : 762 - 766
  • [3] Core Weave Versus Krackow Technique for Achilles Tendon Repair: A Biomechanical Study
    Hong, Yuhwan
    Hermida, Luis
    White, Kacey L.
    Parks, Brent G.
    Camire, Lyn M.
    Guyton, Gregory P.
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (12) : 1107 - 1110
  • [4] The Application of H-Loop in Arthroscopic Knotless Double-Row Rotator Cuff Repairs
    Guo, Jiang
    Hou, Jingyi
    Yu, Menglei
    Alike, Yamuhanmode
    Long, Yi
    Tang, Yiyong
    Li, Qingyue
    Li, Fangqi
    Zhang, Yuhao
    Ali, MaslahIdiris
    Zheng, Zhenze
    Meng, Ke
    Wang, Peng
    Yang, Rui
    ORTHOPAEDIC SURGERY, 2021, 13 (07) : 2170 - 2176
  • [5] Biomechanical comparison of knotless wide suture double-row SutureBridge rotator cuff repair to double-row standard suture repair
    Liu, Victor K.
    Bouwmeester, Theresia M.
    Smith, Geoffrey C. S.
    Lam, Patrick H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) : 1621 - 1626
  • [6] Knotted Versus Knotless Suture Bridge Repair of the Achilles Tendon Insertion A Biomechanical Study
    Cox, Joseph T.
    Shorten, Peter L.
    Gould, Gregory C.
    Markert, Ronald J.
    Barnett, Michael D., Jr.
    Laughlin, Richard T.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (11): : 2727 - 2733
  • [7] Double-Row Bridging Suture Fixation Augmented With Double Krackow Suture for the Repair of Avulsion of the Ossified Achilles Tendon: A Technical Tip
    Yamaguchi, Satoshi
    Endo, Jun
    Yamamoto, Yohei
    Sasho, Takahisa
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (07) : 849 - 852
  • [8] Double-Row Suture Anchor Fixation and Achilles Allograft Augmentation for Chronic Patellar Tendon Rupture Repair
    Cregar, William
    Fortier, Luc M.
    Kerzner, Benjamin
    Dasari, Suhas P.
    Gursoy, Safa
    Chahla, Jorge
    ARTHROSCOPY TECHNIQUES, 2022, 11 (04): : E631 - E638
  • [9] Achilles tendon rupture repair: Biomechanical comparison of the locking block modified Krackow technique and the Giftbox technique
    Tian, Jian
    Rui, Rongjun
    Xu, Yajun
    Yang, Wengbo
    Chen, Xueming
    Zhang, Xingfei
    Xu, Tonglong
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (02): : 559 - 564
  • [10] Triceps tendon rupture. Double-row repair and overview of alternative techniques
    Lange, M.
    Regauer, M.
    Boecker, W.
    Ockert, B.
    UNFALLCHIRURG, 2017, 120 (05): : 437 - 441