Effect of different airway devices on ventilation during cardiopulmonary resuscitation

被引:0
|
作者
Segond, N. [1 ,2 ,3 ]
Fischer, M. [1 ,2 ]
Fontecave-Jallon, J. [3 ]
Podsiadlo, P. [4 ]
Lurie, K. [5 ,6 ]
Bellier, A. [7 ]
Debaty, G. [1 ,2 ,3 ]
机构
[1] Univ Hosp Grenoble Alpes, Emergency Dept, Grenoble, France
[2] Univ Hosp Grenoble Alpes, Mobile Intens Care Unit, Grenoble, France
[3] Univ Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup,Grenoble INP,TIMC, F-38000 Grenoble, France
[4] Jan Kochanowski Univ, Dept Emergency Med, Kielce, Poland
[5] Hennepin Healthcare, Minneapolis, MN USA
[6] Univ Minnesota, Minneapolis, MN USA
[7] Univ Grenoble Alpes, Dept Anat LADAF, Grenoble, France
关键词
Cardiopulmonary resuscitation; Heart arrest; Mechanical ventilation; Respiratory physiology; Respiratory mechanics; HOSPITAL CARDIAC-ARREST; CEREBRAL PERFUSION-PRESSURE; BAG-MASK VENTILATION; ENDOTRACHEAL INTUBATION; MECHANICAL VENTILATION; LARYNGEAL TUBE; HEAD; GUIDELINES; COUNCIL; STRATEGY;
D O I
10.1016/j.resuscitation.2025.110584
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: This study compared face mask, supraglottic airway device (SGA), and endotracheal tube (ETT) ventilation with mechanical ventilation (MV) during cardiopulmonary resuscitation (CPR) in the flat position and with head and thorax elevation (HTE). Methods: Using thawed, fresh-frozen human cadavers this randomized cross-over study compared face mask, SGA, and ETT ventilation using an automated ventilator in the flat and HTE positions. Tidal volume (TV) was set to 8 mL/kg ideal predicted body weight, and expiratory TV (VTe) (mL/ kg) was the primary endpoint. Secondary endpoints included inspiratory TV (VTi), maximal inspiratory airway pressure (Pmax), and leakage between inspiratory and expiratory tidal volumes (VTi-VTe). Results: Data from 8 cadavers and 2302 ventilation cycles were analyzed. In the flat position, VTe was 7.66 +/- 3.75 with ETT, 5.01 +/- 3.14 with SGA, and 5.63 +/- 2.83 with face mask, respectively. A mixed linear model showed the airway device significantly impacted VTe, VTi, Pmax, and VTi-VTe (p < 0.001 for each). Compared with intubation, both face mask and SGA ventilation resulted in lower VTe, lower Pmax, and higher VTi-VTe (p < 0.001 for each). No significant differences were observed between face mask and SGA ventilation. There were higher VTe and lower VTiVTe values (p < 0.001 for each) with HTE versus the flat position (p < 0.001). Conclusions: In human cadavers undergoing CPR, mechanical ventilation through a face mask or SGA versus an ETT was associated with lower VTe, lower Pmax, and higher leakage values in human cadavers during CPR. Head and thorax elevation reduce face mask and SGA airway leakage during CPR and increase VTe.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A survey of ventilation strategies during cardiopulmonary resuscitation
    Liu, Ye-cheng
    Qi, Yan-meng
    Zhang, Hui
    Walline, Joseph
    Zhu, Hua-dong
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2019, 10 (04) : 222 - 227
  • [22] VENTILATION DURING CARDIOPULMONARY RESUSCITATION - WHICH METHOD
    LAWRENCE, PJ
    SIVANESWARAN, N
    MEDICAL JOURNAL OF AUSTRALIA, 1985, 143 (10) : 443 - 446
  • [23] EFFECTS OF AIRWAY OCCLUSION DURING CARDIOPULMONARY RESUSCITATION
    BENHAIM, SA
    SHOFTI, R
    DINNAR, U
    SAIDEL, GM
    JOURNAL OF CRITICAL CARE, 1988, 3 (04) : 240 - 248
  • [24] Ventilation is necessary during cardiopulmonary resuscitation in a rat model of cardiac arrest induced by airway obstruction
    Kurita, Akihide
    Taniguchi, Takumi
    Yamamoto, Ken
    CIRCULATION, 2007, 116 (16) : 935 - 935
  • [25] SIMULTANEOUS CHEST COMPRESSION AND VENTILATION AT HIGH AIRWAY PRESSURE DURING CARDIOPULMONARY RESUSCITATION (CPR) IN MAN
    CHANDRA, N
    RUDIKOFF, M
    WEISFELDT, ML
    CIRCULATION, 1978, 58 (04) : 203 - 203
  • [26] Cardiopulmonary Resuscitation Endotracheal Intubation vs supraglottic Airway Devices
    Strunden, Mike
    NOTARZT, 2016, 32 (02): : 54 - 54
  • [27] Ventilation during cardiopulmonary resuscitation: A review of the literature and an analysis of ventilation strategies
    Wenzel, V
    Lindner, KH
    Prengel, AW
    ANAESTHESIST, 1997, 46 (02): : 133 - 141
  • [28] Use of supraglottic airway devices under capnography monitoring during cardiopulmonary resuscitation: A systematic review
    Jose Cereceda-Sanchez, Francisco
    Molina-Mula, Jesus
    AUSTRALIAN CRITICAL CARE, 2021, 34 (03) : 287 - 295
  • [29] Development of Bioimpedance for the Measurement of Ventilation During Cardiopulmonary Resuscitation
    Prakash, Rithika
    Jarrett, Philip
    Idris, Ahamed
    CIRCULATION, 2024, 150
  • [30] A simple method to prevent aerosol dispersion during Cardiopulmonary Resuscitation using supraglottic airway devices
    Somri, Mostafa
    Gaitini, Luis
    Galante, Dario
    Sanallah, Mhfod
    Hossein, Jalaa
    Gomez-Rios, Manuel angel
    RESUSCITATION, 2021, 159 : 35 - 37