Effect of valve regulation on the operating state of a CO2 two-phase thermosyphon loop

被引:0
|
作者
Tong, Zhen [1 ]
Wang, Wencheng [1 ]
Wang, Peng [1 ]
Han, Zekun [1 ]
Yu, Huili [1 ]
Hu, Songtao [1 ]
机构
[1] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao 266033, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermosyphon loop; CO2; Valve regulation; Operating state; Geyser boiling; Natural circulation oscillation; HEAT-TRANSFER; PERFORMANCE; INSTABILITY; RATIO;
D O I
10.1016/j.csite.2025.106055
中图分类号
O414.1 [热力学];
学科分类号
摘要
During the operation of two-phase thermosyphon loops (TPTLs), different types of oscillations may occur, affecting their safety and performance. Although existing research has preliminarily explored the use of valve regulation to eliminate oscillatory operations in TPTLs, the effects of valves on different types of oscillations have not been verified. In this study, valve regulation was applied to two types of oscillation in a CO2 TPTL. The distinct effects of the valve on each type of oscillation were analyzed in conjunction with their respective mechanisms through experiment. For natural circulation oscillations, valve regulation can effectively suppress fluctuations within the loop. When the valve opening (theta) reduced from 100 % to 75 %, the TPTL transitioned from oscillatory to stable operation. However, the thermal performance of the TPTL remained nearly unaffected. For geyser boiling, valve regulation cannot alter the oscillatory operating state within the loop. Even when the theta was reduced from 100 % to 25 %, the TPTL remained in an oscillatory operating state. The results provide a deeper understanding of the influencing mechanisms of valve regulation and offer insights into the active regulation of TPTLs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Experimental Study on the Small Two-Phase Thermosyphon Loop With Minichannel Evaporator
    Liu, Yang
    Yan, Zhe
    Jiang, Zhenhua
    Li, Nanxi
    Yang, Baoyu
    Wu, Yinong
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (02)
  • [32] Research on the refrigerant column height in the downcomer of a two-phase loop thermosyphon
    Cao, Hanwen
    Ding, Tao
    He, Zhiguang
    Li, Zhen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 : 40 - 48
  • [33] Experimental investigation of two-phase thermosyphon loop for passive containment cooling
    Yin, Xuan
    Hu, Jian
    Chi, Xiangyu
    Li, Yaru
    Nan, Zezhao
    Wang, Naihua
    APPLIED THERMAL ENGINEERING, 2021, 184
  • [34] Thermal performance of a two-phase loop thermosyphon with an additively manufactured evaporator
    Elkholy, Ahmed
    Unlusoy, Can
    Kempers, Roger
    APPLIED THERMAL ENGINEERING, 2022, 202
  • [35] Pressure drop in riser and evaporator in an advanced two-phase thermosyphon loop
    Khodabandeh, R
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05): : 725 - 734
  • [36] Numerical analysis of a closed loop two-phase thermosyphon under states of single-phase, two-phase and supercritical
    Bai, Ye
    Wang, Liang
    Zhang, Shuang
    Lin, Xipeng
    Chen, Haisheng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 : 354 - 367
  • [37] Two-Phase Flow of CO2 with Phase Transfer
    Lund, Halvor
    Aursand, Peder
    6TH TRONDHEIM CONFERENCE ON CO2 CAPTURE, TRANSPORT AND STORAGE, 2012, 23 : 246 - 255
  • [38] A micro-channel cooling system with two-phase looped thermosyphon for a supercritical CO2 Brayton cycle
    Yu, Liqi
    Li, Zhigang
    Guo, Chaohong
    Zhang, Haisong
    Wang, Bo
    Xu, Xiang
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [39] Experimental study on the operating limit of a closed two-phase thermosyphon with a binary mixture
    Kadoguchi, Katsuhiko
    Fukano, Tohru
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1994, 60 (571): : 953 - 959
  • [40] Thermal performance of a closed advanced two-phase thermosyphon loop for cooling of radio base stations at different operating conditions
    Khodabandeh, R
    APPLIED THERMAL ENGINEERING, 2004, 24 (17-18) : 2643 - 2655