Multiple sclerosis lesion detection with 3D double inversion recovery (DIR) as compared to 3D fluid low attenuation inversion recovery (T2-FLAIR): A systematic review and meta-analysis

被引:0
|
作者
Mostardeiro, Thomaz R. [1 ]
Schmitt, Luiza Giuliani [2 ]
de Campos, Fillipe Thiago Xavier [3 ]
Xi, Yin [1 ]
Torri, Giovanni Brondani [4 ]
Carvalho, Bruno Murad [5 ]
Feltrin, Fabricio Stewan [1 ]
机构
[1] Univ Texas Southwestern Med Ctr, Dept Radiol, Dallas, TX USA
[2] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, Dallas, TX USA
[3] Hosp Clin Goias, Dept Radiol, Goiania, Brazil
[4] Hosp Univ Santa Maria, Dept Radiol, Santa Maria, Brazil
[5] Fac Med Barbacena, Barbacena, Brazil
关键词
Lesion detection; DIR; T2-FLAIR; 3D imaging; MRI; CORTICAL-LESIONS; INTRACORTICAL LESIONS; JUXTACORTICAL LESIONS; BRAIN; MRI; IDENTIFICATION; SEQUENCE; MATTER;
D O I
10.1016/j.msard.2024.106186
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Several sequences have been developed to increase lesion detection in Multiple Sclerosis, including Double Inversion Recovery (DIR). The superiority of these pulse sequences is not well established compared to T2-FLAIR images. urpose: This meta-analysis aims to describe if lesion detection rates are higher in DIR compared to T2-FLAIR images in a 3D acquisition comparison. Data Sources: Search was performed of the PubMed/MEDLINE, EMBASE and Cochrane databases between January 1995 and December 2023. Study Selection: Studies identified were assessed independently by two physicians following PRISMA guidelines. Articles were screened to exclude duplicates, review articles, not performing direct 3D DIR and 3D T2-FLAIR comparisons and abstracts. Remaining articles were reviewed in a full-text review by two physicians independently. Data Analysis: Cortical lesion count ranged from to 12.4 to 40.0 for DIR; 5.25 to 27.9 for T2-FLAIR, with juxtacortical lesions ranging from 4.9 to 19.7 and 4.72 to 22.0 on DIR and T2-FLAIR respectively. Intracortical lesions varied from 1.2 to 8.0 for DIR and 1.1 to 3.1 for T2-FLAIR. Infratentorial lesions mean lesions count varied from 2.0 to 12.0 for DIR, as compared to 1.45 to 8.4 for T2-FLAIR. In the periventricular WM, results varied from 11.84 to 73 and 11.31 to 69 for DIR and T2-FLAIR respectively. Data Synthesis: R statistical software was used for data synthesis. Pooled estimates showed relative significant differences in lesion detection for intracortical (175.41 [95 % Confidence Interval (95 %-CI): 48.68; 410.16]) and infratentorial (30.56 [95 %-CI: 9.34; 55.91]) regions with the entire 95 % confidence intervals >0. Confidence intervals were <0 when counting differences for total cortical lesions (37.35 [95 %-CI:12.47; 115.54]), including juxtacortical (25.44 [95 %-CI:32.12; 131.81]) and for supratentorial WM lesions (1.93 [95 %-CI:14.41; 21.39]), including the periventricular WM (11.22 [95 %-CI:4.02; 28.90]). Limitations: The available number of studies was relatively low. Also, given significant heterogenicity for lesion load measurements in different patients for absolute differences, relative differences were only estimated from one study by the log-normal assumption. Conclusions: DIR acquisition allows higher detection in intracortical and infratentorial lesions compared to T2FLAIR.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Infarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery, validation in patients and ex vivo
    Robert Jablonowski
    David Nordlund
    Henrik Engblom
    Joey F Ubachs
    Mikael Kanski
    Hakan Arheden
    Marcus Carlsson
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [32] Infarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery; validation in patients and ex vivo
    Jablonowski, Robert
    Nordlund, David
    Kanski, Mikael
    Ubachs, Joey
    Koul, Sasha
    Heiberg, Einar
    Engblom, Henrik
    Erlinge, David
    Arheden, Hakan
    Carlsson, Marcus
    BMC CARDIOVASCULAR DISORDERS, 2013, 13
  • [33] Infarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery; validation in patients and ex vivo
    Robert Jablonowski
    David Nordlund
    Mikael Kanski
    Joey Ubachs
    Sasha Koul
    Einar Heiberg
    Henrik Engblom
    David Erlinge
    Håkan Arheden
    Marcus Carlsson
    BMC Cardiovascular Disorders, 13
  • [34] Improved detection of multiple sclerosis lesions with T2-prepared double inversion recovery at 3T
    Costagli, Mauro
    Lapucci, Caterina
    Zaca, Domenico
    Bruschi, Nicolo
    Schiavi, Simona
    Castellan, Lucio
    Stemmer, Alto
    Roccatagliata, Luca
    Inglese, Matilde
    JOURNAL OF NEUROIMAGING, 2022, 32 (05) : 902 - 909
  • [35] Magnetic resonance imaging of focal cortical dysplasia: Comparison of 3D and 2D fluid attenuated inversion recovery sequences at 3 T
    Tschampa, Henriette J.
    Urbach, Horst
    Malter, Michael
    Surges, Rainer
    Greschus, Susanne
    Gieseke, Juergen
    EPILEPSY RESEARCH, 2015, 116 : 8 - 14
  • [36] Cortical lesion classification in multiple sclerosis using 3D interleaved phase sensitive inversion recovery imaging and an inherent null point image
    Mougin, O. E.
    Abdel-Fahim, R.
    Hall, E.
    Pitiot, A.
    Gowland, P.
    Evangelou, N.
    MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (11) : 422 - 422
  • [37] Utility of 3-T FLAIR and 3D short tau inversion recovery MR imaging in the preoperative diagnosis of hippocampal sclerosis: Direct comparison with 1.5-T FLAIR MR imaging
    Hashiguchi, Kimiaki
    Morioka, Takato
    Murakami, Nobuya
    Suzuki, Satoshi O.
    Hiwatashi, Akio
    Yoshiura, Takashi
    Sasaki, Tomio
    EPILEPSIA, 2010, 51 (09) : 1820 - 1828
  • [38] Clinical evaluation of white matter lesions on 3D inversion recovery ultrashort echo time MRI in multiple sclerosis
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Afsahi, Amir Masoud
    Reichardt, Benjamin
    Corey-Bloom, Jody
    Du, Jiang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4171 - 4180
  • [39] Rapid T1 quantification based on 3D phase sensitive inversion recovery
    Warntjes M.J.B.
    Kihlberg J.
    Engvall J.
    BMC Medical Imaging, 10 (1)
  • [40] Acute severe memory impairment as a presenting symptom of multiple sclerosis: a clinical case study with 3D double inversion recovery MR imaging
    Coebergh, J. A. F.
    Roosendaal, S. D.
    Polman, C. H.
    Geurts, J. J.
    van Woerkom, T. C. A. M.
    MULTIPLE SCLEROSIS, 2010, 16 (12): : 1521 - 1524