Air-Conditioning Performance Assessment in an Educational Building: A Case Study in Malaysia's Hot and Humid Region

被引:0
|
作者
Dezfouli, M. M. S. [1 ]
Dehghani-Sanij, A. R. [2 ]
Rostami, Sh. [3 ]
Suhairi, R. [1 ]
Kadir, K. [1 ]
机构
[1] Univ Kuala Lumpur, British Malaysian Inst UniKL BMI, Gombak 53100, Malaysia
[2] Univ Waterloo, Waterloo Inst Sustainable Energy WISE, Waterloo, ON N2L 3G1, Canada
[3] Univ Kebangsaan Malaysia, Solar Energy Res Inst SERI, Bangi 43600, Malaysia
来源
关键词
Thermal comfort; cooling system; energy consumption; hot and humid; THERMAL COMFORT; OFFICE;
D O I
10.30880/ijie.2024.16.07.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In regions with high temperatures and humidities, the operation of airconditioning (AC) systems accounts for a sizable portion of buildings' energy use, ranging from 60% to 70%. This energy expenditure is necessary to maintain a thermally comfortable environment inside interior spaces. Therefore, the inadequate functioning of the cooling system has a significant impact on both energy usage and the interior thermal comfort conditions inside the building. Excessive cooling is a common phenomenon observed in Malaysian buildings, with educational institutions and libraries being especially affected. This research aims to identify the underlying cause of excessive cooling in an educational building by assessing the thermal comfort and energy consumption of a fan coil unit (FCU) placed in a selected room in Malaysia's hot and humid environment. A data acquisition system, comprising sensors and a data logger, was set up in multiple locations inside the case study room and the cooling system. This system was used to quantify performance variables, namely temperature, humidity, and airflow, across four FCU process air lines. The measurement data were gathered from 8 AM to 6 PM over the course of one week. Data analysis was carried out using the acquired data to ascertain the distribution of cooling load, assess thermal comfort, and compute the FCU's energy usage. The findings of the cooling load analysis indicate that 52% of the total cooling load, amounting to 9.4 kW, may be attributed to latent loads, while the remaining 48% is associated with sensible loads. The findings of the thermal comfort investigation reveal that the temperature and relative humidity inside the classroom during the operation of the FCU were recorded as 24.3 degrees C and 77.1%, respectively. These values do not align with the desired thermal comfort level of 25 degrees C and 50% humidity. It was discovered that due to the high latent load of the classroom, the FCU is unable to control the humidity level to the appropriate value; therefore, in order to control the humidity, the sensible cooling will be drastically reduced, and overcooling will occur in the space. To attain the optimal interior atmosphere, an optimized FCU has been designed. Compared to the current FCU, the optimized FCU consumes 1.4 times more energy.
引用
收藏
页码:148 / 161
页数:14
相关论文
共 50 条
  • [21] Study on Structure and Performance of Outlast Air-Conditioning Fiber
    Zhang, Hai-Xia
    Xu, Rui-Chao
    Zhai, Ya-Li
    Mao, Hui-Xian
    TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, VOLS 1-3, 2011, : 213 - 218
  • [22] Experimental Study of Cooling Performance of Gravity Air-conditioning
    Li, Cuimin
    Zhao, Jianing
    Fang, Xiumu
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 504 - 510
  • [23] Experimental investigation of heat recovery system for building air conditioning in hot and humid areas
    Delfani, Shahram
    Pasdarshahri, Hadi
    Karami, Maryam
    ENERGY AND BUILDINGS, 2012, 49 : 62 - 68
  • [24] Performance Assessment of Cold Thermal Storage-Based Building Air-Conditioning Layouts for Different Climates
    Singh, Gaurav
    Das, Ranjan
    HEAT TRANSFER ENGINEERING, 2024,
  • [25] Operational characteristics of residential and light-commercial air-conditioning systems in a hot and humid climate zone
    Stephens, Brent
    Siegel, Jeffrey A.
    Novoselac, Atila
    BUILDING AND ENVIRONMENT, 2011, 46 (10) : 1972 - 1983
  • [26] Integrated Design and Assessment for Indoor Heating, Ventilation and Air-Conditioning in Hot Summer and Cold Winter Area: A Case Study in China
    Yang, Ye
    Li, Zhenyu
    BUILDINGS, 2022, 12 (11)
  • [27] PERFORMANCE OF AIR CONDITIONING SYSTEM IN EDUCATIONAL BUILDING FOR ENERGY CONSERVATION
    Limphitakphong, Nantamol
    Chaikatetham, Nuttasate
    Khaimook, Therdthai
    Chavalparit, Orathai
    INTERNATIONAL JOURNAL OF GEOMATE, 2019, 16 (56): : 177 - 182
  • [28] Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
    Bastos, Celso Silva
    Calmon, Joao Luiz
    REVISTA HABITAT SUSTENTABLE, 2013, 3 (02): : 66 - 74
  • [29] Thermal Environment and Energy Performance of a Typical Classroom Building in a Hot-Humid Region: A Case Study in Guangzhou, China
    Yi, Liang
    Xie, Yuan
    Lin, Chang
    GEOFLUIDS, 2022, 2022
  • [30] Thermal Environment and Energy Performance of a Typical Classroom Building in a Hot-Humid Region: A Case Study in Guangzhou, China
    Yi, Liang
    Xie, Yuan
    Lin, Chang
    GEOFLUIDS, 2022, 2022