Optimizing economic performances of foundation earth-to-air heat exchangers for low-technology residential air-conditioning

被引:1
|
作者
Patin, Mathieu [1 ,2 ]
Rousse, Daniel R. [2 ]
机构
[1] Univ Franche Comte, UTBM, CNRS, FEMTO ST, Belfort, France
[2] Univ Quebec, Ecole Technol Super, Grp t3e, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Geothermic; Earth-to-air heat exchanger; Domestic load modeling; TRNSYS; Low technology; Environmental; INTEGRATION; SIMULATION; SYSTEMS; CLIMATE;
D O I
10.1016/j.enbuild.2024.115250
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Despite its classification as a low-technology and nearly passive sustainable system, the use of earth-to-air heat exchangers in residential settings remains relatively uncommon, primarily due to the expenses associated with excavation. Nevertheless, positioning the heat exchanger around the building's foundations during construction offers a potential solution to mitigate these costs. This study conducts an economic viability analysis for such a configuration, focusing on a typical single-family dwelling in Montre<acute accent>al, Canada. A sizing investigation revealed that ducts with relatively small diameters (approximately 20 cm), constructed from cost-effective materials, are optimal. These ducts should be placed as deep and as distant from the foundation as feasible. The optimal heat exchanger configuration reduces the building's heating/cooling load by 701 kWh per year (4.3 %). However, despite minimal excavation expenses, the economic analysis suggests an unviable Levelized cost of Energy for the province of Quebec (0.182 US$.kWh- 1) compared to the low electricity rates in the area (a domestic fare of 0.059 US$.kWh- 1). The findings underscore notable losses attributable to thermal short-circuiting influenced by the basement walls and coupling affected by the mandatory Heat Recovery Ventilation system. Overall, it was determined that only 60 % of the sensible heat exchanged with the soil effectively contributes to load reduction.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Experimental study of the efficiency of earth-to-air heat exchangers: Effect of the presence of external fans
    Ahmad, Hijaz
    Sakhri, Nasreddine
    Menni, Younes
    Omri, Mohamed
    Ameur, Houari
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [42] Improving the performances of earth air heat exchangers through Constructal design
    Brum, Ruth da Silva
    Labat, Matthieu
    Lorente, Sylvie
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 8822 - 8833
  • [43] Earth-Air Heat Exchangers for Passive Air Conditioning: Case Study Burkina Faso
    Woodson, Thomas
    Coulibaly, Yezouma
    Traore, Eric Seydou
    JOURNAL OF CONSTRUCTION IN DEVELOPING COUNTRIES, 2012, 17 (01) : 21 - 32
  • [44] Thermal power loop heat exchangers for heat recovery and thermal control in air-conditioning systems
    Chen, ZQ
    Shi, MH
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 469 - 475
  • [45] ANALYSIS OF THE ACCURACY AND SENSITIVITY OF 8 MODELS TO PREDICT THE PERFORMANCE OF EARTH-TO-AIR HEAT-EXCHANGERS
    TZAFERIS, A
    LIPARAKIS, D
    SANTAMOURIS, M
    ARGIRIOU, A
    ENERGY AND BUILDINGS, 1992, 18 (01) : 35 - 43
  • [46] Parametric Performance Analysis of the Cooling Potential of Earth-to-Air Heat Exchangers in Hot and Humid Climates
    Bughio, Mushk
    Bahale, Swati
    Mahar, Waqas Ahmed
    Schuetze, Thorsten
    ENERGIES, 2022, 15 (19)
  • [47] Earth-to-air heat exchangers for passive houses located in South-Eastern European countries
    Badescu, Viorel
    Tudor, Alexandru
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (04)
  • [48] Refrigerant control strategies for residential air-conditioning and heat-pump system
    Su, Shun-Yu
    Zhang, Chun-Zhi
    Chen, Jian
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 91 - 95
  • [50] Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System
    SU ShunyuZHANG ChunzhiCHEN JianCollege of Urban ConstructionWuhan University of Science and TechnologyWuhanHubei China
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 91 - 95