Optimization of GEM detectors for applications in X-ray fluorescence imaging

被引:0
|
作者
de Souza, G. G. A. [1 ]
da Luz, H. N. [2 ]
Bregant, M. [1 ]
机构
[1] Univ Sao Paulo, Inst Fis, Rua Matao 1371 Cidade Univ, BR-05508090 Sao Paulo, Brazil
[2] Czech Tech Univ, Inst Expt & Appl Phys, Husova 5, Prague 1, Czech Republic
关键词
Gas Electron Multiplier; X-ray fluorescence imaging; GEM copper fluorescence; TRIPLE-GEM; SOFT; KR; AR;
D O I
10.1016/j.radphyschem.2024.112263
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work a set of simulations that aim at the optimization of Micropattern Gaseous Detectors (MPGD) for applications in X-ray fluorescence imaging in the energy range of 3 - 30 keV is presented. By studying the statistical distribution of electrons from interactions of X-rays with gases, the energy resolution limits after charge multiplication for 6 keV X-ray photons in Ar/CO2(70/30) 2 (70/30) and Kr/CO2(90/10) 2 (90/10) were calculated, resulting in energy resolutions of 15.4(4)% and 14.6(2)% respectively. These two mixtures were studied in simulations to evaluate the advantages of using krypton-based mixtures to reduce the presence of escape peaks in fluorescence spectra. A model to evaluate the X-ray fluorescence from the conductive materials inside the detectors was implemented, serving as a tool to estimate the extent of contamination of fluorescence spectra when using copper or aluminum layers in the material composition of MPGDs.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Determination of X-ray detection limit and applications in perovskite X-ray detectors
    Pan, Lei
    Shrestha, Shreetu
    Taylor, Neil
    Nie, Wanyi
    Cao, Lei R.
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [32] Imaging theory for X-ray pixel detectors
    Anton, G
    Durst, J
    Firsching, M
    Giersch, J
    Korn, A
    Mitschke, M
    Niederlhöner, D
    Pfeiffer, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 116 - 123
  • [33] A new generation of direct X-ray detectors for medical and synchrotron imaging applications
    Datta, A.
    Zhong, Z.
    Motakef, S.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [34] Detectors for X-ray Coherent Diffractive Imaging
    Hall, Christopher J.
    Lewis, Robert A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 130 - 132
  • [35] Novel X-ray detectors for medical imaging
    Knüpfer, W
    Hell, E
    Mattern, D
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 610 - 615
  • [36] A new generation of direct X-ray detectors for medical and synchrotron imaging applications
    A. Datta
    Z. Zhong
    S. Motakef
    Scientific Reports, 10
  • [37] Characterization of Edgeless CdTe Detectors for use in Hard X-Ray Imaging Applications
    Veale, Matthew C.
    Bell, Steven J.
    Jones, Lawrence L.
    Seller, Paul
    Wilson, Matthew D.
    Cernik, Robert C.
    Kalliopuska, Juha
    Pohjonen, Harri
    Andersson, Hans
    Nenonen, Seppo
    Kachkanov, Vyacheslav
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1536 - 1543
  • [38] Evaluation of Controlled-Drift Detectors in X-Ray Spectroscopic Imaging Applications
    Castoldi, Andrea
    Guazzoni, Chiara
    Ozkan, Cigdem
    Vedani, Giorgio
    Hartmann, Robert
    Bjeoumikhov, Aniouar
    MICROSCOPY AND MICROANALYSIS, 2009, 15 (03) : 231 - 236
  • [39] X-ray fluorescence and X-ray transmission microtomography imaging system
    Pereira, Gabriela R.
    Rocha, Henrique S.
    Anjos, Marcelino J.
    Faria, Paulo
    Perez, Carlos A.
    Lopes, Ricardo T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 128 - 132
  • [40] Cryogenic detectors and their application to x-ray fluorescence analysis
    Frank, Matthias
    Friedrich, Stephan
    Hoehne, Jens
    Jochum, Josef
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2003, 11 (02) : 83 - 112