Energy, exergy and economic analysis of a novel immersion tapered solar still for combination with solar concentrator

被引:1
|
作者
Chang, Zehui [1 ,2 ]
Yang, Jie [1 ,3 ]
Chu, Yaqi [1 ]
Hou, Jin [4 ]
Su, Yuehong [5 ]
机构
[1] Inner Mongolia Univ Technol, Coll Energy & Power Engn, Hohhot 010051, Peoples R China
[2] Inner Mongolia Univ Technol, Engn Ctr Solar Energy Utilizat Technol, Hohhot 010051, Peoples R China
[3] Lyuliang Univ, Dept Phys & Elect Informat Engn, Luliang 033000, Peoples R China
[4] Inner Mongolia Tech Coll Construct, Coll Bldg Equipment & Automat, Hohhot 010070, Peoples R China
[5] Univ Nottingham, Dept Architecture & Built Environm, Nottingham NG7 2RD, England
基金
中国国家自然科学基金;
关键词
Desalination; Immersion tapered; Solar still; Water cooling; PRODUCTIVITY ENHANCEMENT; BASIN-TYPE; DESALINATION; WATER; PERFORMANCE; HEAT; TEMPERATURES;
D O I
10.1016/j.desal.2025.118560
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The methods of strengthening moisture condensation rate of solar still will make its structure complicated. Here, a novel immersion tapered solar desalination device composed of a solar concentrator and a tapered solar still in this paper, which can easily achieve condensation enhancement by water cooling. The heat and mass transfer characteristics of the tapered solar still is assessed experimentally and theoretically, and the mathematical models of energy transfer and exergy destruction in the still are established to analyze various aspects of its performance including yield, energy, exergy and economics. The results show that the calculated values of the mathematical model are in good agreement with the experimental results, and the variation trend is consistent. When the heating power is 170 W, the steady-state evaporation temperature of the single-effect still is 74.1 degrees C, and the deviation from the theoretical calculation result is 1.2 %. The steady-state freshwater yield rate is 37.63 g/15 min, and the deviation from the theoretical calculation result is 19.6 %. The double-effect still can effectively recycle the heat loss, and its freshwater yield rate and gain output ratio (GOR) can reach 64.88 g/15 min and 0.99 in steady state operation. Immersion water cooling of the still can significantly improve its heat and mass transfer characteristics and freshwater yield rate, and the higher the operating temperature, the greater the performance improvement of the still by immersion water cooling. When the heating temperature is 75 degrees C, the temperature difference between evaporation surface and condensation surface of the 1st effect and 2nd effect of the still with immersion water cooling are 4.9 degrees C and 19.3 degrees C, respectively, which are 2.7 degrees C and 12.0 degrees C higher than those under natural air cooling conditions. At this time, the freshwater yield rate of the still under immersion water cooling conditions reached 0.732 kg/h, which is 0.446 kg/h higher than that under natural air cooling conditions. What's more, the cost per liter of freshwater production (CPL) and payback period for the double-effect immersion tapered solar desalination device are 0.023 $/L and 3.42 years, respectively.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Energy, exergy, and economic analysis of single slope conventional solar still augmented with an ultrasonic fogger and a cotton cloth
    Dumka, Pankaj
    Jain, Ananya
    Mishra, Dhananjay R.
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [32] Energy and exergy analysis of conventional acrylic solar still with and without copper fins
    Vaithilingam, Sivakumar
    Muthu, Vimala
    Athikesavan, Muthu Manokar
    Afzal, Asif
    Sathyamurthy, Ravishankar
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (04) : 6194 - 6204
  • [33] Energy and exergy analysis of single slope passive solar still: an experimental investigation
    Vaithilingam, Sivakumar
    Esakkimuthu, Ganapathy Sundaram
    DESALINATION AND WATER TREATMENT, 2015, 55 (06) : 1433 - 1444
  • [34] Experimental Investigations of a Single-Slope Solar Still: Energy and Exergy Analysis
    Ali, Haider
    Ali, Sajid
    Khan, Sikandar
    Siddiqui, Muhammad Umar
    ENERGIES, 2023, 16 (22)
  • [35] Energy and exergy analysis of conventional acrylic solar still with and without copper fins
    Sivakumar Vaithilingam
    Vimala Muthu
    Muthu Manokar Athikesavan
    Asif Afzal
    Ravishankar Sathyamurthy
    Environmental Science and Pollution Research, 2022, 29 : 6194 - 6204
  • [36] Analysis of a solar still with photovoltaic modules and electrical heater - Energy and exergy approach
    Arani Rajendra Prasad
    Muthu Manokar Athikesavan
    Abd Elnaby Kabeel
    Manegalai Govindan Sumithra
    Ravishankar Sathyamurthy
    Amrit Kumar Thakur
    Environmental Science and Pollution Research, 2022, 29 : 57453 - 57465
  • [37] A novel solar desalination system integrating inclined and tubular solar still with parabolic concentrator
    Ahmed, Mohamed M. Z.
    Alshammari, Fuhaid
    Alatawi, Ibrahim
    Alhadri, Muapper
    Elashmawy, Mohamed
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [38] Exergy analysis and economic estimate of a novel solar and gas combined system
    Wang, Gang
    Wang, Shukun
    Jiang, Tieliu
    Chen, Zeshao
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
  • [39] Exergy analysis of solar energy applications
    Saidur, R.
    BoroumandJazi, G.
    Mekhilef, S.
    Jameel, M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01): : 350 - 356
  • [40] Energy and exergy analysis of solar combisystems
    Kacan, Erkan
    Ulgen, Koray
    INTERNATIONAL JOURNAL OF EXERGY, 2014, 14 (03) : 364 - 387