Long-term clinical outcomes of isolated orbital floor fracture reconstruction using nonresorbable implants

被引:0
|
作者
Abd El Ghafar, Ayman E. [1 ]
Shawky, Nashaat [1 ]
Shaheen, Mahrous Hassan [2 ]
Aziz, Khalid Abdel [3 ]
Diab, Mostafa Mohamed [2 ,4 ]
机构
[1] Mansoura Univ, Ophthalm Ctr, Dept Ophthalmol, Mansoura, Egypt
[2] Fayoum Univ, Fac Med, Dept Ophthalmol, Al Fayoum, Egypt
[3] Beni Suef Univ, Fac Med, Dept Ophthalmol, Bani Suwayf, Egypt
[4] King Saud Univ, King Saud Univ Med City, Coll Med, Dept Ophthalmol, Riyadh, Saudi Arabia
关键词
Long-term outcomes; orbital floor fracture; polypropylene mesh; porous polyethylene sheet; titanium mesh; POROUS POLYETHYLENE CHANNEL; MESH; REPAIR; ADHERENCE; SECONDARY; DIPLOPIA; SURGERY;
D O I
10.4103/IJO.IJO_1100_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: There are no universally established guidelines for material selection in orbital wall fracture reconstruction. With an increasing preference for permanent implants, this study aimed to compare the long-term clinical outcomes of three different non-resorbable materials in reconstructing isolated orbital floor fractures. Design: A retrospective, interventional comparative study. Methods: The medical records of patients with unilateral pure orbital floor fractures who underwent orbital reconstruction using non-resorbable alloplastic implants at two tertiary referral centers between January 2017 to December 2021 were reviewed. Cases with non-pure orbital floor blowout fractures and/or <2 years of follow-up were excluded. Patients were separated into three groups according to the implant material type: porous polyethylene (PPE) sheet, polypropylene (PP) mesh, and titanium (Ti) mesh. These groups were then retrospectively analyzed for clinical outcomes, implant-related complications, and patient's satisfaction. Results: Sixty-six patients met the inclusion criteria. Twenty-four patients (36.36%) received PPE sheets, 20 patients (30.3%) had PP mesh, and 22 patients (33.33%) received Ti mesh. At the 6-month postoperative visit, nine patients (40.9%) in the Ti mesh group experienced postoperative diplopia compared to six patients (30.0%) in the PP group and one patient (4.2%) in the PPE group (P < 0.047). Following the initial 6-month postoperative period, the PP group had more frequent postoperative enophthalmos compared to the other 2 groups. The total ocular motility restriction score was significantly lower in the Ti mesh group compared to the other 2 groups at all follow-up visits. Patient's satisfaction was significantly higher in the PPE group (median = 10, IQR = 1) compared to the PP (median = 8.5, IQR = 3) and Ti groups (median = 8, IQR = 3), P < 0.001. Reoperation was needed in seven patients (31.8%) in the Ti group, two patients (10%) in the PP group, and none in the PPE group. Conclusions: The use of PPE orbital implants for the repair of isolated orbital floor fracture provides better long-term clinical outcomes compared to PP or Ti mesh and reduces the need for reoperation across all fracture sizes. Ti mesh has been associated with a higher frequency of unfavorable clinical outcomes and implant removal.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Radiologic and Facial Morphologic Long-Term Results in Treatment of Orbital Floor Fracture With Flexible Absorbable Alloplastic Material
    Gerressen, Marcus
    Gillessen, Simone
    Riediger, Dieter
    Hoelzle, Frank
    Modabber, Ali
    Ghassemi, Alireza
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (10) : 2375 - 2385
  • [32] Reconstruction of Isolated Axillary Nerve Lesions: Clinical and Electrophysiological Long-Term Results
    Hug, U.
    Vital, D.
    Guggenheim, M.
    Jung, F. J.
    Giovanoli, P.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2011, 43 (06) : 351 - 355
  • [33] Long-term functional outcomes of cochlear implants in children
    Laszig, R.
    Aschendorff, A.
    Beck, R.
    Schild, C.
    Kroeger, S.
    Wesarg, T.
    Arndt, S.
    HNO, 2009, 57 (07) : 657 - 662
  • [35] Long-term outcomes of patients with artificial iris implants
    Khan, Haaris M.
    Eslami, Maryam
    Khan, Hamza N.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2023, 58 (04): : E168 - E171
  • [36] Long-term outcomes of nail bed reconstruction
    Koh, Sung Hoon
    You, Youngkee
    Kim, Yong Woo
    Kim, Jin Soo
    Lee, Dong Chul
    Roh, Si Young
    Lee, Kyung Jin
    Hong, Min Ki
    ARCHIVES OF PLASTIC SURGERY-APS, 2019, 46 (06): : 580 - 588
  • [37] LONG-TERM CLINICAL OUTCOMES OF PATIENTS WITH SIROLIMUS-ELUTING STENT FRACTURE
    Kim, Ung
    Kim, Dong-Kie
    Seol, Sang-Hoon
    Yang, Tae-Hyun
    Kim, Dae-Kyeong
    Kim, Doo-Il
    Kim, Dong-Soo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [38] Frailty assessment, hip fracture and long-term clinical outcomes in older adults
    Pizzonia, Monica
    Giannotti, Chiara
    Carmisciano, Luca
    Signori, Alessio
    Rosa, Gianmarco
    Santolini, Federico
    Caffa, Irene
    Montecucco, Fabrizio
    Nencioni, Alessio
    Monacelli, Fiammetta
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2021, 51 (04)
  • [39] Long-term Clinical Outcomes of Patients With Sirolimus-Eluting Stent Fracture
    Kim, Ung
    Kim, Dong-Kie
    Kim, Young-Bok
    Seol, Sang-Hoon
    Yang, Tae-Hyun
    Kim, Dae-Kyung
    Kim, Doo-Il
    Kim, Dong-Soo
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 63D - 64D
  • [40] Quantitative assessment of increase in orbital volume after orbital floor fracture reconstruction using a bioabsorbable implant
    Hyun Young Park
    Tae Hyung Kim
    Jin Sook Yoon
    JaeSang Ko
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 3027 - 3036