Long-term clinical outcomes of isolated orbital floor fracture reconstruction using nonresorbable implants

被引:0
|
作者
Abd El Ghafar, Ayman E. [1 ]
Shawky, Nashaat [1 ]
Shaheen, Mahrous Hassan [2 ]
Aziz, Khalid Abdel [3 ]
Diab, Mostafa Mohamed [2 ,4 ]
机构
[1] Mansoura Univ, Ophthalm Ctr, Dept Ophthalmol, Mansoura, Egypt
[2] Fayoum Univ, Fac Med, Dept Ophthalmol, Al Fayoum, Egypt
[3] Beni Suef Univ, Fac Med, Dept Ophthalmol, Bani Suwayf, Egypt
[4] King Saud Univ, King Saud Univ Med City, Coll Med, Dept Ophthalmol, Riyadh, Saudi Arabia
关键词
Long-term outcomes; orbital floor fracture; polypropylene mesh; porous polyethylene sheet; titanium mesh; POROUS POLYETHYLENE CHANNEL; MESH; REPAIR; ADHERENCE; SECONDARY; DIPLOPIA; SURGERY;
D O I
10.4103/IJO.IJO_1100_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: There are no universally established guidelines for material selection in orbital wall fracture reconstruction. With an increasing preference for permanent implants, this study aimed to compare the long-term clinical outcomes of three different non-resorbable materials in reconstructing isolated orbital floor fractures. Design: A retrospective, interventional comparative study. Methods: The medical records of patients with unilateral pure orbital floor fractures who underwent orbital reconstruction using non-resorbable alloplastic implants at two tertiary referral centers between January 2017 to December 2021 were reviewed. Cases with non-pure orbital floor blowout fractures and/or <2 years of follow-up were excluded. Patients were separated into three groups according to the implant material type: porous polyethylene (PPE) sheet, polypropylene (PP) mesh, and titanium (Ti) mesh. These groups were then retrospectively analyzed for clinical outcomes, implant-related complications, and patient's satisfaction. Results: Sixty-six patients met the inclusion criteria. Twenty-four patients (36.36%) received PPE sheets, 20 patients (30.3%) had PP mesh, and 22 patients (33.33%) received Ti mesh. At the 6-month postoperative visit, nine patients (40.9%) in the Ti mesh group experienced postoperative diplopia compared to six patients (30.0%) in the PP group and one patient (4.2%) in the PPE group (P < 0.047). Following the initial 6-month postoperative period, the PP group had more frequent postoperative enophthalmos compared to the other 2 groups. The total ocular motility restriction score was significantly lower in the Ti mesh group compared to the other 2 groups at all follow-up visits. Patient's satisfaction was significantly higher in the PPE group (median = 10, IQR = 1) compared to the PP (median = 8.5, IQR = 3) and Ti groups (median = 8, IQR = 3), P < 0.001. Reoperation was needed in seven patients (31.8%) in the Ti group, two patients (10%) in the PP group, and none in the PPE group. Conclusions: The use of PPE orbital implants for the repair of isolated orbital floor fracture provides better long-term clinical outcomes compared to PP or Ti mesh and reduces the need for reoperation across all fracture sizes. Ti mesh has been associated with a higher frequency of unfavorable clinical outcomes and implant removal.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects
    Ozturk, S
    Sengezer, M
    Isik, S
    Turegun, M
    Deveci, M
    Cil, Y
    JOURNAL OF CRANIOFACIAL SURGERY, 2005, 16 (06) : 973 - 977
  • [2] Reconstruction of the orbital floor with polydioxanone: a long-term clinical survey of up to 12 years
    Beck-Broichsitter, Benedicta Elisabeth
    Acar, Carolin
    Kandzia, Christian
    Jochens, Arne
    Wiltfang, Joerg
    Becker, Stephan T.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (08): : 736 - 740
  • [3] Endoscopic Reconstruction of Isolated Orbital Floor Wall Fracture Considering Orbital Floor Slope
    Park, Jinhwan
    Yang, Sungwon
    Lee, Joonsik
    Chang, Minwook
    Lee, Hwa
    Park, Minsoo
    Baek, Sehyun
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (04) : E340 - E343
  • [4] Long-Term Outcomes of Pegged and Unpegged Bioceramic Orbital Implants
    Karslioglu, Safak
    Buttanri, Ibrahim Bulent
    Fazil, Korhan
    Serin, Didem
    Akbaba, Muslime
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 28 (04): : 264 - 267
  • [5] Long-term infectious complications of using porous polyethylene mesh for orbital fracture reconstruction
    Song, Xuefei
    Li, Lunhao
    Sun, Yiyuan
    Fan, Xianqun
    Li, Zhengkang
    MEDICINE, 2016, 95 (25)
  • [6] Surgical Outcomes of Orbital Fracture Reconstruction Using Patient-Specific Implants
    Blumer, Michael
    Essig, Harald
    Steigmiller, Klaus
    Wagner, Maximilian Eberhard
    Gander, Thomas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (06) : 1302 - 1312
  • [7] LONG-TERM STABILITY OF TEFLON ORBITAL IMPLANTS
    ARONOWITZ, JA
    FREEMAN, BS
    SPIRA, M
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 78 (02) : 166 - 173
  • [8] Long-term Effect of Individualized Titanium Mesh in Orbital Floor Reconstruction After Maxillectomy
    Sun, Qian
    Soh, Hui-Yuh
    Zhang, Wen-bo
    Yu, Yao
    Wang, Yang
    Mao, Chi
    Guo, Chuan-bin
    Yu, Guang-yan
    Peng, Xin
    LARYNGOSCOPE, 2021, 131 (10): : 2231 - 2237
  • [9] Pediatric Orbital Floor Reconstruction Using a Nonresorbable Polypropylene-Based Hernia Mesh: A Case Report
    Sharma, Gauri
    Shukla, Deepankar
    Bhola, Nitin D.
    Vishnani, Rozina
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [10] Replacement of Shaped Textured Implants with Round Smooth Implants in Breast Reconstruction: Long-Term Outcomes
    Ayyala, Haripriya S.
    Afifi, Tarek
    Castel, Nikki
    McCarthy, Colleen
    Cordeiro, Peter G.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (02) : 265 - 271