Estimation of Absolute Blood Volume Using Online Dialysate Dilution: When and How to Measure?

被引:0
|
作者
Kron, Joachim [1 ]
Kron, Susanne [1 ,2 ]
机构
[1] Kidney Ctr Berlin Koepenick, Kuratorium Dialyse & Nierentransplantat KfH, Erwin Bock St 5, D-12559 Berlin, Germany
[2] Deutsch Rotes Kreuz DRK Clin Berlin Koepenick, Dept Nephrol, Berlin, Germany
关键词
absolute blood volume; dialysate dilution method; standardized; measurement; hemodialysis; automated volume management;
D O I
10.1097/MAT.0000000000002284
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Absolute blood volume can be calculated from the increase in relative blood volume after an infusion of a well-defined volume bolus of ultrapure dialysate into the extracorporeal circulation. Several working groups have applied this method in research and clinical practice. A critical analysis of differing blood volume data between working groups revealed methodologic problems of the measurement procedure and some important technical aspects. This paper presents a statement to standardize the method.
引用
收藏
页码:e54 / e57
页数:4
相关论文
共 50 条
  • [21] MEASUREMENT OF ABSOLUTE CORONARY BLOOD-FLOW USING A HYDROGEN DILUTION CATHETER
    VOGEL, RA
    BEAUMAN, GJ
    FRIEDMAN, HZ
    MANCINI, GBJ
    CLINICAL RESEARCH, 1985, 33 (04): : A870 - A870
  • [22] High volume online post-dilution hemodiafiltration: how relevant is it in chronic kidney disease?
    Martins Castro, Manuel Carlos
    JORNAL BRASILEIRO DE NEFROLOGIA, 2022, 44 (02): : 238 - 243
  • [23] Blood volume studies VII. Comparative values of Welcker, carbon monoxide and dye methods for blood volume determinations. Accurate estimation of absolute blood volume
    Smith, HP
    Arnold, HR
    Whipple, GH
    AMERICAN JOURNAL OF PHYSIOLOGY, 1921, 56 (02): : 336 - 360
  • [24] How to improve learning when going online using POPBL
    Borch, Ole E. M.
    Helbo, Jan
    Madsen, Per Printz
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON WEB-BASED EDUCATION, 2007, : 92 - +
  • [26] How to measure the wave function absolute squared of a moving particle by using mirrors
    Hannstein, V.
    Hegerfeldt, G. C.
    EPL, 2007, 77 (06)
  • [27] Room impulse response estimation using sparse online prediction and absolute loss
    Crammer, Koby
    Lee, Daniel D.
    2006 IEEE International Conference on Acoustics, Speech and Signal Processing, Vols 1-13, 2006, : 3199 - 3202
  • [28] AN ULTRASONIC QUANTITATIVE BLOOD-FLOW MEASURING SYSTEM TO MEASURE THE ABSOLUTE VOLUME FLOW-RATE
    FURUHATA, H
    KANNO, R
    KODAIRA, K
    FUJISHIRO, K
    YOSHIMURA, S
    HAYASHI, J
    MASTUMOTO, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 789 - 790
  • [29] ESTIMATION OF VOLUME OF EPITHELIAL LINING FLUID RECOVERED BY LAVAGE USING UREA AS MARKER OF DILUTION
    RENNARD, SI
    BASSET, G
    LECOSSIER, D
    ODONNELL, KM
    PINKSTON, P
    MARTIN, PG
    CRYSTAL, RG
    JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (02) : 532 - 538