Multiobjective optimization guided by image quality index for limited-angle CT image reconstruction

被引:0
|
作者
He, Yu [1 ]
Wang, Chengxiang [1 ]
Yu, Wei [2 ,3 ]
Wang, Jiaxi [4 ]
机构
[1] Chongqing Normal Univ, Sch Math Sci, Chongqing 401331, Peoples R China
[2] Hubei Univ Sci & Technol, Xianning Med Coll, Sch Biomed Engn & Imaging, Xianning 437100, Peoples R China
[3] Hubei Univ Sci & Technol, Key Lab Optoeletron & Intelligent Control, Xianning, Peoples R China
[4] Chengdu Univ, Coll Comp Sci, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
CT reconstruction; limited-angle CT; image quality assessment; multiobjective optimization; TOTAL VARIATION MINIMIZATION; COMPUTED-TOMOGRAPHY; FRAME; TOMOSYNTHESIS; ALGORITHM;
D O I
10.3233/XST-240111
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Due to the incomplete projection data collected by limited-angle computed tomography (CT), severe artifacts are present in the reconstructed image. Classical regularization methods such as total variation (TV) minimization, t0 minimization, are unable to suppress artifacts at the edges perfectly. Most existing regularization methods are single-objective optimization approaches, stemming from scalarization methods for multiobjective optimization problems (MOP). OBJECTIVE: To further suppress the artifacts and effectively preserve the edge structures of the reconstructed image. METHOD: This study presents a multiobjective optimization model incorporates both data fidelity term and t0-norm of the image gradient as objective functions. It employs an iterative approach different from traditional scalarization methods, using the maximization of structural similarity (SSIM) values to guide optimization rather than minimizing the objective function.The iterative method involves two steps, firstly, simultaneous algebraic reconstruction technique (SART) optimizes the data fidelity term using SSIM and the Simulated Annealing (SA) algorithm for guidance. The degradation solution is accepted in the form of probability, and guided image filtering (GIF) is introduced to further preserve the image edge when the degradation solution is rejected. Secondly, the result from the first step is integrated into the second objective function as a constraint, we use t0 minimization to optimize t0-norm of the image gradient, and the SSIM, SA algorithm and GIF are introduced to guide optimization process by improving SSIM value like the first step. RESULTS: With visual inspection, the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and SSIM values indicate that our approach outperforms other traditional methods. CONCLUSIONS: The experiments demonstrate the effectiveness of our method and its superiority over other classical methods in artifact suppression and edge detail restoration.
引用
收藏
页码:1209 / 1237
页数:29
相关论文
共 50 条
  • [31] Curvature constraint based image reconstruction for limited-angle computed tomography
    Xue, Xiao
    Zhao, Shusen
    Zhao, Yunsong
    Zhang, Peng
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [32] Limited-angle CT Reconstruction with lp Regularization
    Deng, Xiaojuan
    Liu, Xuehong
    Li, Hongwei
    THIRD INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE (ISICDM 2019), 2019, : 182 - 186
  • [33] A non-smooth and non-convex regularization method for limited-angle CT image reconstruction
    Zhang, Lingli
    Zeng, Li
    Wang, Chengxiang
    Guo, Yumeng
    JOURNAL OF INVERSE AND ILL-POSED PROBLEMS, 2018, 26 (06): : 799 - 820
  • [34] Limited-Angle CT Image Reconstruction Based on Swin-Transformer Iterative Unfolding for PTCT Imaging
    Yuan Wei
    Xi Yarui
    Tan Chuandong
    Liu Chuanjiang
    Zhu Guorong
    Liu Fenglin
    ACTA OPTICA SINICA, 2024, 44 (08)
  • [35] Reconstruction of limited-angle and few-view nano-CT image via total variation iterative reconstruction
    Liang, Zhiting
    Guan, Yong
    Liu, Gang
    Bian, Rui
    Zhang, Xiaobo
    Xiong, Ying
    Tian, Yangchao
    X-RAY NANOIMAGING: INSTRUMENTS AND METHODS, 2013, 8851
  • [36] An iterative algorithm for computed tomography image reconstruction from limited-angle projections
    Sun Y.-L.
    Tao J.-X.
    Chen H.
    Liu C.-G.
    Journal of Shanghai Jiaotong University (Science), 2015, 20 (02) : 202 - 208
  • [37] ITERATIVE RELAXATION TECHNIQUES FOR IMAGE-RECONSTRUCTION FROM LIMITED-ANGLE PROJECTIONS
    BABA, N
    SHIRAKAWA, H
    OSE, T
    OPTIK, 1984, 68 (04): : 335 - 340
  • [38] Photoacoustic image reconstruction from few-detector and limited-angle data
    Yao, Lei
    Jiang, Huabei
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (09): : 2649 - 2654
  • [39] Euler's Elastica Strategy for Limited-Angle Computed Tomography Image Reconstruction
    Zhang, Hanming
    Wang, Linyuan
    Duan, Yuping
    Li, Lei
    Hu, Guoen
    Yan, Bin
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (08) : 2395 - 2405
  • [40] Image reconstruction based on nonlinear diffusion model for limited-angle computed tomography
    Zhao, Xuying
    Jiang, Wenjin
    Zhang, Xinting
    Guo, Wenxiu
    Zhao, Yunsong
    Zhao, Xing
    INVERSE PROBLEMS, 2024, 40 (04)