Radiation Exposure and Protection in Computed Tomography Fluoroscopy

被引:5
|
作者
Nakatani, Miyuki [1 ]
Kariya, Shuji [1 ]
Ono, Yasuyuki [1 ]
Maruyama, Takuji [1 ]
Ueno, Yutaka [1 ]
Komemushi, Atsushi [1 ]
Tanigawa, Noboru [1 ]
机构
[1] Kansai Med Univ, Dept Radiol, Hirakata, Japan
关键词
radiation safety; interventional radiology; CT fluoroscopy; CT FLUOROSCOPY; SCATTERED RADIATION; PHYSICIANS HAND; PATIENT; INTERVENTIONS; REDUCTION; DOSIMETRY;
D O I
10.22575/interventionalradiology.2022-0010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomography (CT) fluoroscopy-guided procedures, such as those used for percutaneous biopsy, drainage, and radiofrequency ablation, are highly safe and quite often very successful due to the precision offered by the real-time, high-resolution tomographic images. Even so, international guidelines raised concerns regarding operator exposure to high doses of radiation during these procedures. In light of these concerns, operators conducting CT fluoroscopy-guided procedures not only need to be cognizant of the exposure risk but also exhibit sufficient knowledge of radiation protection. This paper reviews the current literature on experimental and clinical studies of radiation exposure doses to operators during CT fluoroscopy-guided procedures. In addition to the literature review, this paper also introduces different approaches that can be implemented to ensure appropriate radiation protection.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [21] Computed tomography associated radiation exposure in children with craniosynostosis
    Bruce, Madeleine K.
    Mittal, Aditya M.
    Whitt, Darunee S.
    Flom, Lynda L.
    Pfaff, Miles J.
    Losee, Joseph E.
    Goldstein, Jesse A.
    CHILDS NERVOUS SYSTEM, 2021, 37 (08) : 2635 - 2641
  • [22] Computed tomography. A great source of radiation exposure
    Raslawski, Elsa C.
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2008, 106 (03): : 273 - 274
  • [23] Intraoperative fluoroscopy, portable X-ray, and computed tomography: patient and operating room personnel radiation exposure in spinal surgery
    Nelson, Elisha M.
    Monazzam, Shafagh M.
    Kim, Kee D.
    Siebert, J. Anthony
    Klineberg, Eric O.
    SPINE JOURNAL, 2015, 15 (04): : 799 - 800
  • [24] EXPOSURE TO RADIATION DURING FLUOROSCOPY
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1957, 163 (05): : 410 - 410
  • [25] EXPOSURE TO RADIATION DURING FLUOROSCOPY
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1957, 163 (12): : 1096 - 1096
  • [26] Radiation protection in the design of λ-ray industrial computed tomography systems
    Ri-Feng Zhou
    Xiao-Jian Zhou
    Xiao-Bin Li
    Ping Li
    Nuclear Science and Techniques, 2016, 27 (04) : 23 - 29
  • [27] Radiation protection in the design of γ-ray industrial computed tomography systems
    Ri-Feng Zhou
    Xiao-Jian Zhou
    Xiao-Bin Li
    Ping Li
    Nuclear Science and Techniques, 2016, 27
  • [28] Radiation protection in the design of γ-ray industrial computed tomography systems
    Zhou, Ri-Feng
    Zhou, Xiao-Jian
    Li, Xiao-Bin
    Li, Ping
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (04)
  • [29] Analysis of the temporal response of computed tomography fluoroscopy
    Hsieh, J
    MEDICAL PHYSICS, 1997, 24 (05) : 665 - 675
  • [30] Computed tomography guidance. Fluoroscopy and more
    Paprottka, P. M.
    Helmberger, T.
    Reiser, M. F.
    Trumm, C. G.
    RADIOLOGE, 2013, 53 (11): : 974 - 985