The effect of sub-boiling temperatures on mass transfer from former manufactured gas plant residuals

被引:1
|
作者
Wei, Yunxiao [1 ,2 ,3 ]
Mumford, Kevin G. [4 ]
Thomson, Neil R. [2 ]
Li, Shupeng [1 ,3 ,5 ]
Guo, Guanlin [6 ]
Xia, Tianxiang [7 ]
Liu, Peng [1 ,3 ]
机构
[1] BCEG Environm Remediat Co Ltd, Beijing 100015, Peoples R China
[2] Univ Waterloo, Dept Civil & Environm Engn, Waterloo, ON, Canada
[3] Natl Engn Lab Site Remediat Technol, Beijing 100015, Peoples R China
[4] Queens Univ, Dept Civil Engn, Kingston, ON, Canada
[5] Tsinghua Univ, Sch Environm, Beijing 100084, Peoples R China
[6] Minist Ecol & Environm, Tech Ctr Soil Agr & Rural Ecol & Environm, Beijing 100012, Peoples R China
[7] Beijing Municipal Res Inst Ecoenvironm Protect, Beijing 100037, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
Remediation; Sub-boiling temperatures; Manufactured gas plant residual; Coal tar; Mass transfer enhancement; Polycyclic aromatic hydrocarbons; POLYCYCLIC AROMATIC-HYDROCARBONS; COAL-TAR; CHEMICAL OXIDATION; CONTAMINATED SOILS; DISSOLUTION; WATER; PAHS; BIOAVAILABILITY; AVAILABILITY; SOLUBILITIES;
D O I
10.1016/j.jconhyd.2025.104508
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dissolution of polycyclic aromatic hydrocarbons (PAHs) from coal tar at former manufactured gas plant (FMGP) sites is a long-term threat to groundwater quality. The dissolution rate is often limited by an increase in the viscosity of the non-aqueous phase liquid (NAPL) as the lower molecular weight compounds are depleted over time, and this slow mass transfer prevents the effective application of remediation technologies that rely on NAPL-to-water mass transfer to remove or degrade mass. Increasing subsurface temperatures has the potential to increase mass transfer at FMGP sites by increasing PAH solubility and reducing NAPL viscosity. This study investigated the mass transfer of PAH compounds from a synthetic NAPL mixture and FMGP residual at 25, 50 and 80 degrees C using well-mixed batch experiments. Effective solubilities increased by up to an order of magnitude and mass transfer rate coefficients increased by up to a factor of 45. Enhancements were greater for higher molecular weight compounds, and for the more complex FMGP NAPL compared to the synthetic mixture due to a more substantial decrease in NAPL viscosity. Simulations using a screening-level model demonstrated the potential for sub-boiling temperature to increase NAPL mass removal at FMGP sites, with increases in concentration up to a factor of seven, and 6 to 87 % of mass remaining after heating to 80 degrees C for 120 days compared to 25 degrees C.
引用
收藏
页数:10
相关论文
共 31 条
  • [21] EFFECT OF ANGLE OF INCLINATION ON LIQUID-PHASE CONTROLLED MASS-TRANSFER FROM A GAS SLUG
    NIGAM, KDP
    PANDIT, AB
    NIRANJAN, K
    CHEMICAL ENGINEERING SCIENCE, 1995, 50 (02) : 289 - 298
  • [22] ADIABATIC SORPTION OF DILUTE SINGLE ADSORBATE FROM AN INERT GAS-EFFECT OF GAS-SOLID MASS AND HEAT TRANSFER COEFFICIENTS
    Kumar, Ravi
    Sircar, Shivaji
    CHEMICAL ENGINEERING COMMUNICATIONS, 1984, 26 (4-6) : 339 - 354
  • [23] ADIABATIC SORPTION OF BULK SINGLE ADSORBATE FROM AN INERT GAS-EFFECT OF GAS-SOLID MASS AND HEAT TRANSFER COEFFICIENTS
    Kumar, Ravi
    Sircar, Shivaji
    CHEMICAL ENGINEERING COMMUNICATIONS, 1984, 26 (4-6) : 319 - 338
  • [24] Effect of source conditions on mass-transfer from nonaqueous phase liquids to soil gas in the vadose zone
    Petri, Benjamin G.
    Illangasekare, Tissa
    Christ, John
    Sakaki, Toshihiro
    Sauck, Carolyn
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [25] Effect of pressure, subcooling, and dissolved gas on pool boiling heat transfer from microporous, square pin-finned surfaces in FC-72
    Rainey, KN
    You, SM
    Lee, S
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (01) : 23 - 35
  • [26] Effect of surfactant lengths on gas-liquid oxygen mass transfer from a single rising bubble (vol 247, 117102, 2022)
    Lebrun, Gaelle
    Benaissa, Sanae
    Men, Claude Le
    Pimienta, Veronique
    Hebrard, Gilles
    Dietrich, Nicolas
    CHEMICAL ENGINEERING SCIENCE, 2022, 256
  • [27] Effect of spheroid bubble interface contamination on gas-liquid mass transfer at intermediate Reynolds numbers: From DNS to Sherwood numbers
    Dani, Adil
    Cockx, Arnaud
    Legendre, Dominique
    Guiraud, Pascal
    CHEMICAL ENGINEERING SCIENCE, 2022, 248
  • [28] Simultaneous removal of SO2 and trace SeO2 from flue gas:: Effect of product layer on mass transfer
    Li, Yuzhong
    Tong, Huiling
    Zhuo, Yuqun
    Chen, Changhe
    Xu, Xuchang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (13) : 4306 - 4311
  • [29] EFFECT OF AXIAL CHANGES IN GAS-FLOW RATE ON VALUES OF MASS-TRANSFER AND DISPERSION COEFFICIENTS COMPUTED FROM COLUMN MEASUREMENTS
    LINEK, V
    SINKULE, J
    PETRICEK, P
    KRIVSKY, Z
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1982, 21 (01): : 87 - 90
  • [30] Effect of surfactants and biomass on the gas/liquid mass transfer in an aqueous-silicone oil two-phase partitioning bioreactor using Rhodococcus erythropolis T902.1 to remove VOCs from gaseous effluents
    Aldric, Jean-Marc
    Gillet, Sebastien
    Delvigne, Frank
    Blecker, Christophe
    Lebeau, Frederic
    Wathelet, Jean-Paul
    Manigat, Geralda
    Thonart, Philippe
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2009, 84 (09) : 1274 - 1283