High-Performance Perovskite Flat Panel X-Ray Imagers via Blade Coating

被引:0
|
作者
Zhang, Aiping [1 ,2 ]
Tie, Shujie [1 ]
Lu, Xiaojuan [1 ]
Tian, Wanjia [1 ]
Fan, Zhenghui [1 ]
Dong, Siyin [1 ]
Yuan, Ruihan [1 ]
Wu, Congcong [2 ]
Zheng, Xiaojia [1 ]
机构
[1] China Acad Engn Phys, Inst Chem Mat, Sichuan Res Ctr New Mat, Chengdu 610200, Peoples R China
[2] Hubei Univ, Sch Mat Sci & Engn, Key Lab Green Preparat & Applicat Funct Mat, Hubei Key Lab Polymer Mat, Wuhan 430062, Peoples R China
来源
SMALL METHODS | 2024年
基金
中国国家自然科学基金;
关键词
blade-coating; low noise; perovskite; X-ray detection;
D O I
10.1002/smtd.202401342
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Perovskite X-ray detectors are recognized as the most promising candidates for low-dose detectors due to their superior performance. However, it is still full of challenging in the fabrication of flat-panel X-ray imagers (FPXIs), primarily due to the absence of large area thick films that exhibit high uniformity and long-term performance stability. A general synthesis route is urgently needed to grow large-scale halide perovskite thick films directly on a pixeled thin-film transistor (TFT) backplane with high uniformity, closing the gap between the great potential of perovskite X-ray detectors and their entry into the market. In this work, an advanced precursor paste suitable for blade coating is developed to enable high-throughput manufacturing of FPXIs. Highly uniform perovskite films with a thickness of 300-micrometers are directly deposited onto pixeled TFT substrates by the blade-coating method using the above paste, which governs a stable dark current and minimal noise of the X-ray detectors. As a result, (BA)2(MA)9Pb10I31 perovskite X-ray detectors achieved a high sensitivity of 15200 mu C Gyair-1 cm-2 and a limit of detection (LoD) of 26.8 nGyair s-1. Moreover, FPXIs with a spatial resolution of 0.95 lp mm-1 (0.475 lp pixel-1) are obtained, which exhibits negligible signal crosstalk and excellent X-ray imaging performance.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Two-Dimensional Perovskite Single Crystals for High-Performance X-ray Imaging and Exploring MeV X-ray Detection
    Xu, Xieming
    Wu, Yiheng
    Zhang, Yi
    Li, Xiaohui
    Wang, Fang
    Jiang, Xiaoming
    Wu, Shaofan
    Wang, Shuaihua
    ENERGY & ENVIRONMENTAL MATERIALS, 2024, 7 (01)
  • [22] Two-Dimensional Perovskite Single Crystals for High-Performance X-ray Imaging and Exploring MeV X-ray Detection
    Xieming Xu
    Yiheng Wu
    Yi Zhang
    Xiaohui Li
    Fang Wang
    Xiaoming Jiang
    Shaofan Wu
    Shuaihua Wang
    Energy & Environmental Materials, 2024, 7 (01) : 143 - 150
  • [23] Performance characteristics of an amorphous silicon flat panel X-ray imaging detector
    Granfors, PR
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 480 - 490
  • [24] Fluoroscopic performance of an amorphous silicon flat panel x-ray imaging detector
    Granfors, PR
    RADIOLOGY, 1998, 209P : 161 - 161
  • [25] High-Performance Fully Printable Perovskite Solar Cells via Blade-Coating Technique under the Ambient Condition
    Yang, Zhibin
    Chueh, Chu-Chen
    Zuo, Fan
    Kim, Jong H.
    Liang, Po-Wei
    Jen, Alex K-Y
    ADVANCED ENERGY MATERIALS, 2015, 5 (13)
  • [26] High resolution, direct detection x-ray imagers
    Street, RA
    Ready, SE
    Rahn, JT
    Mulato, M
    Shah, K
    Bennett, PR
    Mei, P
    Lu, JP
    Apte, RB
    Ho, J
    van Schuylenbergh, K
    Lemmi, F
    Boyce, JB
    Nylen, P
    Schieber, M
    Hermon, H
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 418 - 428
  • [27] HIGH-SPEED GATED X-RAY IMAGERS
    KILKENNY, JD
    BELL, P
    HANKS, R
    POWER, G
    TURNER, RE
    WIEDWALD, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1793 - 1796
  • [28] FLAT-PANEL DIGITAL X-RAY IMAGERS - CLINICAL IMPLEMENTATION IN RADIATION-THERAPY AND OPTIMIZATION FOR RADIOGRAPHY AND FLUOROSCOPY
    ANTONUK, LE
    ELMOHRI, Y
    SIEWERDSEN, JH
    YORKSTON, J
    HUANG, W
    RADIOLOGY, 1995, 197 : 449 - 449
  • [29] High resolution large formatted CMOS flat panel sensors for X-ray
    Fujita, K
    Mori, H
    Kyuushima, R
    Honda, M
    Yamamoto, K
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2114 - 2118
  • [30] Large formatted and high resolution CMOS flat panel sensors for X-ray
    Mori, H
    Kyuushima, R
    Fujita, K
    Honda, M