Nonlinearity parameter estimation method from fundamental band signal depletion in pulse-echo using a dual-energy model

被引:0
|
作者
Coila, Andres [1 ]
Romero, Adriana [1 ]
Oelze, Michael L. [2 ]
Lavarello, Roberto [1 ]
机构
[1] Pontificia Univ Catolica Peru, Dept Ingn, Lab Imagenes Med, Lima, Peru
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Elect & Comp Engn, Urbana, IL 61801 USA
来源
基金
美国国家卫生研究院;
关键词
ACOUSTIC NONLINEARITY; IMAGING METHODS; B/A; COEFFICIENT;
D O I
10.1121/10.0036215
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The estimation of the nonlinearity parameter (B/A) has the potential to be used in the clinical diagnosis of conditions such as liver steatosis. Recently, a pulse-echo method to estimate B/A based on the theory of the fundamental band amplitude depletion of weak waves, namely, the depletion method, was proposed. In the present work, the depletion method is presented with more technical detail. Then, the robustness of the depletion method is assessed by using simulations that diverge from the model requirements: (1) monochromatic plane wave propagation and (2) quadratic power-law frequency dependence attenuation. Regarding requirement (1), the results led to a critical finding that when using wideband pulses (37%-113% bandwidth), the bias of the B/A estimates is larger than the bias obtained using narrowband pulses (11%-28% bandwidth), even if requirement (2) holds. Regarding requirement (2), power-law frequency dependence closer to those of soft tissues, i.e., 1.1 or 1.2, using narrowband pulses presented bias of less than 10%. The use of narrowband pulses also was shown to be robust when the reference phantom and sample had attenuation mismatches of around 60%. Finally, the experimental feasibility of the depletion method was evaluated, showing results with good accuracy (bias <17%), which are consistent with the observations in the simulations. (c) 2025 Acoustical Society of America.
引用
收藏
页码:1969 / 1980
页数:12
相关论文
共 29 条
  • [21] COMPUTING STRUCTURAL PARAMETERS FROM DUAL-ENERGY X-RAY ABSORPTIOMETRY USING A 3D RECONSTRUCTION METHOD
    Humbert, Ludovic
    Whitmarsh, Tristan
    Del Rio Barquero, Luis Miguel
    Frangi, Alejandro F.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S349 - S350
  • [22] FEMORAL STRENGTH PREDICTION USING A 3D RECONSTRUCTION METHOD FROM DUAL-ENERGY X-RAY ABSORPTIOMETRY
    Humbert, Ludovic
    Whitmarsh, Tristan
    Fritscher, Karl
    del Rio Barquero, Luis Miguel
    Eckstein, Felix
    Link, Thomas
    Schubert, Rainer
    Frangi, Alejandro F.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1451 - 1454
  • [23] Fast Solutions of Wide-band RCS of Objects Using General Characteristic Basis Function Method with the Model Based Parameter Estimation
    Nie, Wenyan
    Wang, Zhonggen
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 1160 - 1163
  • [24] An online model-based battery parameter and state estimation method using multi-scale dual adaptive particle filters
    Ye, Min
    Guo, Hui
    Xiong, Rui
    Mu, Hao
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105
  • [25] An online model-based method for state of energy estimation of lithium-ion batteries using dual filters
    Dong, Guangzhong
    Chen, Zonghai
    Wei, Jingwen
    Zhang, Chenbin
    Wang, Peng
    JOURNAL OF POWER SOURCES, 2016, 301 : 277 - 286
  • [26] Basis Vector Model Based Method for Proton Stopping Power Estimation From Experimental Dual Energy CT Data
    Zhang, S.
    Han, D.
    Politte, D.
    Porras-Chaverri, M.
    Whiting, B.
    Williamson, J.
    O'Sullivan, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3756 - 3756
  • [27] Development of a spinal load evaluation method from human body mass distribution using DXA (dual-energy X-ray absorptiometry)
    Kawai, Takashi
    Ushida, Takahiro
    Inoue, Shinsuke
    Ikemoto, Tatsunori
    Arai, Young-Chang P.
    Nishihara, Makoto
    PAIN RESEARCH, 2014, 29 (03) : 181 - 189
  • [28] Validity of a Multi-compartment Body Composition Model Using Body Volume Derived from Dual-Energy X-ray Absorptiometry
    Mock, Meredith
    Ryan, Eric D.
    Gerstner, Gena R.
    Tweedell, Andrew J.
    Kleinberg, Craig R.
    Hirsch, Katie R.
    Trexler, Eric T.
    Smith-Ryan, Abbie E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 1036 - 1036
  • [29] Evaluation of the Modulation Transfer Function from a Model-Based and a Statistical-Based Hybrid Iterative Reconstruction Algorithm Using Single-Energy and Dual-Energy CT
    Olguin, E.
    Leon, S.
    Olguin, C.
    Arreola, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E377 - E378