Validation of 2-dimensional ultrasound imaging protocols for measuring the masseter muscle

被引:0
|
作者
Lin, Min [1 ]
Leotta, Daniel F. [2 ]
Chen, Matthew B. [3 ]
Lee, Peggy P. [4 ]
机构
[1] Univ Washington, Sch Dent, Seattle, WA USA
[2] Univ Washington, Ctr Ind & Med Ultrasound, Appl Phys Lab, Seattle, WA USA
[3] Tufts Univ, Sch Dent Med, Boston, MA USA
[4] Univ Washington, Dept Oral Med, Oral & Maxillofacial Radiol Residency Program, Seattle, WA 98195 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2025年 / 139卷 / 05期
关键词
TEMPOROMANDIBULAR DISORDERS; INJECTIONS; SIZE; PAIN;
D O I
10.1016/j.oooo.2024.12.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective(s). To determine the most repeatable ultrasound imaging protocols for assessing the masseter muscle, evaluating repeatability across different scan locations, muscle contraction states, and operator positions. Study Design. Ten adult volunteers underwent ultrasound scans, including three axial (superior/middle/inferior) and three longitudinal (anterior/middle/posterior) views on the left and right sides and in the relaxed and clenched states. Each subject was scanned twice, roughly 15 minutes apart. Muscle borders were manually traced on all images. Muscle thickness was calculated using custom software. Agreement between scans was assessed using the Bland-Altman plot. Results. (1) High intra- and inter-rater reliability (intraclass correlation coefficient = 0.99 and intraclass correlation coefficient = 0.98, respectively) for muscle thickness measurement. (2) Thickness at the image center is similar to the average muscle thickness. (3) The longitudinal middle location had the greatest repeatability, regardless of muscle state. (4) Scans at both relaxed and clenched state are repeatable, with relaxed scans yielding slightly greater repeatability. (5) Operator position showed negligible effect on repeatability. (6) Location of the maximum thickness increase in the clenched state varied between subjects. Conclusion(s). The study identified longitudinal middle location as the most repeatable ultrasound transducer position to measure masseter muscle, regardless of muscle contraction state or the operator position. (Oral Surg Oral Med Oral Pathol Oral Radiol 2025;139:600-611)
引用
收藏
页码:600 / 611
页数:12
相关论文
共 50 条
  • [31] 2-DIMENSIONAL CURRENT-DENSITY IMAGING
    PESIKAN, P
    JOY, MLG
    SCOTT, GC
    HENKELMAN, RM
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (06) : 1048 - 1053
  • [32] 2-DIMENSIONAL IMAGING OF METASTABLE CO MOLECULES
    JONGMA, RT
    RASING, T
    MEIJER, G
    JOURNAL OF CHEMICAL PHYSICS, 1995, 102 (05): : 1925 - 1933
  • [33] 2-dimensional transducer array for sonar imaging
    Desilets, CS
    Anderson, RC
    Bohley, T
    Vaughan, DK
    Nikodym, L
    Abboud, N
    Wojcik, GL
    Mould, J
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 999 - 1002
  • [34] PRESENTATION AND VALIDATION OF THE 2-DIMENSIONAL PROCESS SIMULATOR OSIRIS
    GUILLEMOT, N
    CHENEVIER, P
    DEROUXDAUPHIN, P
    GONCHOND, JP
    REVUE DE PHYSIQUE APPLIQUEE, 1984, 19 (12): : 987 - 995
  • [35] Methods of Masseter and Temporal Muscle Thickness and Elasticity Mea-surements by Ultrasound Imaging: A Literature Review
    Blicharz, Gabriela
    Rymarczyk, Malgorzata
    Rogulski, Mateusz
    Linek, Pawel
    CURRENT MEDICAL IMAGING, 2021, 17 (06) : 707 - 713
  • [36] Application of Deep Learning in Quantitative Analysis of 2-Dimensional Ultrasound Imaging of Nonalcoholic Fatty Liver Disease
    Cao, Wen
    An, Xing
    Cong, Longfei
    Lyu, Chaoyang
    Zhou, Qian
    Guo, Ruijun
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (01) : 51 - 59
  • [37] A SEMIAUTOMATIC DEVICE FOR MEASURING RADIOACTIVITY ON 2-DIMENSIONAL PAPER CHROMATOGRAMS
    MOSES, V
    LONBERGHOLM, KK
    ANALYTICAL BIOCHEMISTRY, 1963, 5 (01) : 11 - &
  • [38] MEASURING 2-DIMENSIONAL FRACTAL PATTERNS - THE ROLE OF THE DEFINITION OF DIMENSION
    VIQUEZ, S
    RODRIGUEZLUGO, V
    VAZQUEZPOLO, G
    CASTANO, VM
    COMPUTATIONAL MATERIALS SCIENCE, 1995, 4 (02) : 172 - 180
  • [39] A lesion detection observer study comparing 2-dimensional versus fully 3-dimensional whole-body PET imaging protocols
    Lartizien, C
    Kinahan, PE
    Comtat, C
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (04) : 714 - 723
  • [40] VALIDATION OF THE HISTOGRAM TECHNIQUE FOR 3-DIMENSIONAL AND 2-DIMENSIONAL DOSIMETRIC CALCULATIONS
    VANDIEREN, EB
    VANLINGEN, A
    ROOS, JC
    TEULE, GJJ
    APPLIED RADIATION AND ISOTOPES, 1992, 43 (10) : 1211 - 1221