Comparison of recovery times by using bispectral index monitoring versus end-tidal agent concentration monitoring in patients undergoing inhalational general anaesthesia

被引:0
|
作者
Chaudhuri, Shalini [1 ]
Banerjee, Sandipan [1 ]
Chattopadhyay, Uddalak [1 ]
Hussain, Syed S. [1 ]
机构
[1] Homi Bhabha Canc Hosp, Mahamana Pandit Madan Mohan Malviya Canc Ctr, Dept Anaesthesiol Crit Care & Pain, Varanasi, Uttar Pradesh, India
关键词
Anaesthesia recovery period; consciousness monitors; sevoflurane; AWARENESS; SURGERY;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: End-tidal anaesthetic gas concentration (ETAG) and bispectral index (BIS) are both used to monitor depth of anaesthesia. Maintaining an accurate depth of anaesthesia helps in early post-operative recovery. This study compared the recovery times from sevoflurane-nitrous oxide anaesthesia using ETAG monitoring with BIS monitoring. Methods: Four hundred and two patients undergoing elective surgeries under sevoflurane- nitrous oxide anaesthesia were enroled in this double blinded parallel group prospective randomised trial and allocated into two groups. The depth of anaesthesia was monitored using BIS in BIS group (n = 202) and end-tidal sevoflurane concentration (EtSevo) in ETAG group (n = 200). The time to extubation and recovery were compared between the groups. Parametric, non-parametric and categorical variables were compared using Student's 't' test, Wilcoxon's rank sum test and Chi-square test, respectively. Results: Time to extubation (min) [BIS group - 10, 5; ETAG group - 10, 5 (median, inter-quartile range, IQR), P = 0.32] and time to recovery (min) [BIS group - 14, 6; ETAG group - 13.5, 7 (median, IQR), P = 0.34] did not differ significantly between the two groups. The EtSevo concentration (vol%) was significantly higher in the BIS group at 5 min [BIS group - 1.2, 0.4; ETAG group - 1.0, 0.4 (median, IQR), P < 0.001], 30 min [BIS group - 1.1, 0.4; ETAG group - 1.0, 0.3 (median, IQR), P = 0.002] and 120 min [BIS group - 1.11 +/- 0.28; ETAG group - 0.96 +/- 0.27 (mean +/- standard deviation), P = 0.014] after induction of anaesthesia. Conclusions: BIS and ETAG monitoring are associated with comparable recovery profiles. ETAG monitoring is associated with significantly less sevoflurane consumption.
引用
收藏
页码:S161 / S168
页数:8
相关论文
共 50 条
  • [21] COMPARISON OF BISPECTRAL INDEX AND ENTROPY MONITORING IN PATIENTS UNDERGOING LIVING DONOR LIVER TRANSPLANTATION
    Kim, Gaabsoo
    Lee, Sanghyun
    Jee, Hyeonsook
    Bang, Yujeong
    TRANSPLANT INTERNATIONAL, 2017, 30 : 534 - 534
  • [22] Effect of Bispectral Index versus End Tidal Anaesthetic Gas Concentration on Time to Tracheal Extubation for Isoflurane Based General Anaesthesia-A Prospective Observational Study
    Jain, Shalini
    Pandya, Ravina
    Arora, Kishore Kumar
    Gupta, Neetu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (07) : 11 - 14
  • [23] Non-invasive carbon dioxide monitoring in patients with cystic fibrosis during general anesthesia: end-tidal versus transcutaneous techniques
    Anne May
    Chris Humston
    Julie Rice
    Christopher J. Nemastil
    Ann Salvator
    Joseph Tobias
    Journal of Anesthesia, 2020, 34 : 66 - 71
  • [24] Non-invasive carbon dioxide monitoring in patients with cystic fibrosis during general anesthesia: end-tidal versus transcutaneous techniques
    May, Anne
    Humston, Chris
    Rice, Julie
    Nemastil, Christopher J.
    Salvator, Ann
    Tobias, Joseph
    JOURNAL OF ANESTHESIA, 2020, 34 (01) : 66 - 71
  • [25] Detection of fluid volume absorption by end-tidal alcohol monitoring in patients undergoing endoscopic renal pelvic surgery
    Konrad, C
    Gerber, H
    Schupfer, G
    Jenzer, S
    Schmucki, O
    JOURNAL OF CLINICAL ANESTHESIA, 1999, 11 (05) : 386 - 390
  • [26] END-TIDAL CO2 MONITORING IN MITRAL-STENOSIS PATIENTS UNDERGOING CLOSED MITRAL COMMISSUROTOMY
    PURI, GD
    VENKATRAMAN, R
    SINGH, H
    ANAESTHESIA, 1991, 46 (06) : 494 - 496
  • [27] Automated control of end-tidal volatile anaesthetic concentration using the MIRUS™ system: a comparison of isoflurane, sevoflurane and desflurane in anaesthesia
    V Vinnikov
    D Drees
    J Herzog-Niescery
    P Gude
    H Vogelsang
    B Cevik
    T Weber
    M Bellgardt
    Critical Care, 19 (Suppl 1):
  • [28] Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired-end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
    Dias, Raylene
    Dave, Nandini
    Agrawal, Barkha
    Baghele, Aarti
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (04) : 277 - 283
  • [29] The effects of bispectral index monitoring on hemodynamics and recovery profile in developmentally delayed pediatric patients undergoing dental surgery
    Sargin, Mehmet
    Uluer, Mehmet Selcuk
    Ozmen, Sadik
    PEDIATRIC ANESTHESIA, 2015, 25 (09) : 950 - 955
  • [30] Effects of bispectral index monitoring during anaesthesia on isoflurane consumption, hemodynamic variables and recovery profiles in elderly Pakistani patients
    Shafiq, Faraz
    Naqvi, Hamid
    Ahmed, Aliya
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 154 - 155