Comparison of recovery times by using bispectral index monitoring versus end-tidal agent concentration monitoring in patients undergoing inhalational general anaesthesia

被引:0
|
作者
Chaudhuri, Shalini [1 ]
Banerjee, Sandipan [1 ]
Chattopadhyay, Uddalak [1 ]
Hussain, Syed S. [1 ]
机构
[1] Homi Bhabha Canc Hosp, Mahamana Pandit Madan Mohan Malviya Canc Ctr, Dept Anaesthesiol Crit Care & Pain, Varanasi, Uttar Pradesh, India
关键词
Anaesthesia recovery period; consciousness monitors; sevoflurane; AWARENESS; SURGERY;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: End-tidal anaesthetic gas concentration (ETAG) and bispectral index (BIS) are both used to monitor depth of anaesthesia. Maintaining an accurate depth of anaesthesia helps in early post-operative recovery. This study compared the recovery times from sevoflurane-nitrous oxide anaesthesia using ETAG monitoring with BIS monitoring. Methods: Four hundred and two patients undergoing elective surgeries under sevoflurane- nitrous oxide anaesthesia were enroled in this double blinded parallel group prospective randomised trial and allocated into two groups. The depth of anaesthesia was monitored using BIS in BIS group (n = 202) and end-tidal sevoflurane concentration (EtSevo) in ETAG group (n = 200). The time to extubation and recovery were compared between the groups. Parametric, non-parametric and categorical variables were compared using Student's 't' test, Wilcoxon's rank sum test and Chi-square test, respectively. Results: Time to extubation (min) [BIS group - 10, 5; ETAG group - 10, 5 (median, inter-quartile range, IQR), P = 0.32] and time to recovery (min) [BIS group - 14, 6; ETAG group - 13.5, 7 (median, IQR), P = 0.34] did not differ significantly between the two groups. The EtSevo concentration (vol%) was significantly higher in the BIS group at 5 min [BIS group - 1.2, 0.4; ETAG group - 1.0, 0.4 (median, IQR), P < 0.001], 30 min [BIS group - 1.1, 0.4; ETAG group - 1.0, 0.3 (median, IQR), P = 0.002] and 120 min [BIS group - 1.11 +/- 0.28; ETAG group - 0.96 +/- 0.27 (mean +/- standard deviation), P = 0.014] after induction of anaesthesia. Conclusions: BIS and ETAG monitoring are associated with comparable recovery profiles. ETAG monitoring is associated with significantly less sevoflurane consumption.
引用
收藏
页码:S161 / S168
页数:8
相关论文
共 50 条
  • [1] Comparison of recovery times by using bispectral index monitoring versus end-tidal agent concentration monitoring in patients undergoing inhalational general anaesthesia
    Chaudhuri, Shalini
    Banerjee, Sandipan
    Chattopadhyay, Uddalak
    Hussain, Syed S.
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 : S161 - S168
  • [2] Comparison of bispectral index and end-tidal anaesthetic concentration monitoring on recovery profile of desflurane in patients undergoing lumbar spine surgery
    Sudhakaran, R.
    Makkar, Jeetinder K.
    Jain, Divya
    Wig, Jyotsna
    Chabra, R.
    INDIAN JOURNAL OF ANAESTHESIA, 2018, 62 (07) : 516 - 523
  • [3] The effects of bispectral index monitoring on end-tidal desflurane concentration
    Kaymak, C.
    Takmaz, S. A.
    Ozen, M.
    Ozcan, A. O.
    Gulhan, Y.
    Dikmen, B.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 40 - 40
  • [4] The effect of bispectral index monitoring on end-tidal gas concentration and recovery duration after outpatient anesthesia
    Pavlin, DJ
    Hong, JY
    Freund, PR
    Koerschgen, ME
    Bower, JO
    Bowdle, TA
    ANESTHESIA AND ANALGESIA, 2001, 93 (03): : 613 - 619
  • [5] Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
    Galante, Dario
    Fortarezza, Donatella
    Caggiano, Maria
    de Francisci, Giovanni
    Pedrotti, Dino
    Caruselli, Marco
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2015, 65 (05): : 379 - 383
  • [6] End-tidal carbon dioxide monitoring during paediatric general anaesthesia
    Woodham, V.
    Railton, K. L.
    ANAESTHESIA, 2018, 73 (05) : 646 - 647
  • [7] Bispectral Index Monitoring to Guide End-Tidal Isoflurane Concentration at Three Phases of Operation in Patients With End-Stage Liver Disease Undergoing Orthotopic Liver Transplantation
    Toprak, H. I.
    Sener, A.
    Gedik, E.
    Ucar, M.
    Karahan, K.
    Aydogan, M. S.
    Ersoy, M. O.
    TRANSPLANTATION PROCEEDINGS, 2011, 43 (03) : 892 - 895
  • [8] Comparison of bispectral index and end tidal anaesthetic gas concentration guided protocols on recovery profile for desflurane based general anaesthesia in adult surgical patients
    Priyanka, Deepthi
    Kachru, Nisha
    Singh, Jyoti
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2024, 16 (02)
  • [9] End-tidal carbon dioxide monitoring during paediatric general anaesthesia - a reply
    Brooks, K.
    Anwar, S.
    Stacey, S.
    ANAESTHESIA, 2018, 73 (05) : 647 - +
  • [10] Comparison of sevoflurane-nitrous oxide anaesthesia with the conventional intravenous-inhalational technique using bispectral index monitoring
    Shah, MK
    Tan, HM
    Wong, K
    ANAESTHESIA, 2001, 56 (04) : 302 - 308