The feasibility of a serial 12-lead ECG wireless patch in the hospital setting

被引:0
|
作者
Carey, Mary G. [1 ,2 ]
Mummidi, Sudhir K. [1 ]
Kammer, Amanda [2 ]
Dzikowicz, Dillon J. [1 ,2 ]
机构
[1] Univ Rochester, Sch Nursing, Rochester, NY USA
[2] Univ Rochester, Med Ctr, Rochester, NY USA
关键词
Chest pain; ECG patch; Serial ECG monitoring; Transient myocardial ischemia; Hospitalization; CHEST-PAIN; PROGNOSTIC INFORMATION; AMERICAN-COLLEGE; TROPONIN-T; ELECTROCARDIOGRAM; COMMITTEE;
D O I
10.1016/j.jelectrocard.2024.153828
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Chest pain is the second most common reason to present to the emergency department in the United States, and the ECG is a first-line diagnostic tool for myocardial ischemia assessment. For patients with ongoing symptoms or unclear initial ECGs, guidelines recommend performing multiple standard ECGs at 15-30-min intervals during the first 1-2 h, which improves acute coronary syndrome (ACS) detection by 15 % and accelerates triage of high-risk ACS patients. However, obtaining serial ECG is not consistently practiced due to overcrowding and the limited technical abilities of current 12-lead ECG machines. This study aimed to evaluate an FDAapproved wireless 12-lead ECG patch for serial cardiac monitoring in the hospital setting. Methods: Prospectively, ECG patch was applied in the Mason-Likar electrode configuration after obtaining consent. The patch remained in place for at least one hour. Clinical Utility of the ECGs was categorized from 1 to 3: 1 = uninterpretable, 2 = borderline, and 3 = interpretable. Results: Among hospitalized cardiac patients, 28 consented to wear the ECG patch for at least one hour and patients were free to ambulate during the study. Most (70 %) patients were in sinus rhythm, and an episode of asymptomatic TMI was captured. The clinical utility of the ECGs (n = 364) was mostly interpretable, 64 % (n = 231), while 15 % (n = 55) were uninterpretable and 18 % (n = 65) were borderline. Most (69 %) preferred the patch, while 12 % preferred telemetry. The hospitalized cardiac patients reported significantly better ability to ambulate with the ECG patch (Z = -3.607, p < 0.001). Conclusion: Thus, this experiment demonstrated that the ECG patch provides quality serial ECG monitoring and captures TMI of hospitalized cardiac patients without increasing burden.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Wang, Lu-di
    Zhou, Wei
    Xing, Ying
    Liu, Na
    Movahedipour, Mahmood
    Zhou, Xiao-guang
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2019, 20 (03) : 405 - 413
  • [32] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di WANG
    Wei ZHOU
    Ying XING
    Na LIU
    Mahmood MOVAHEDIPOUR
    Xiao-guang ZHOU
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 (03) : 405 - 413
  • [33] A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di Wang
    Wei Zhou
    Ying Xing
    Na Liu
    Mahmood Movahedipour
    Xiao-guang Zhou
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 405 - 413
  • [34] The V-Quick patch versus the standard 12-lead ECG system: time is the essence
    F. Lateef
    A. Annathurai
    T. T. Loh
    International Journal of Emergency Medicine, 2008, 1 (1) : 43 - 48
  • [35] The V-Quick patch versus the standard 12-lead ECG system: time is the essence
    Lateef, F.
    Annathurai, A.
    Loh, T. T.
    INTERNATIONAL JOURNAL OF EMERGENCY MEDICINE, 2008, 1 : 43 - 48
  • [36] Detection of culprit coronary lesion location in pre-hospital 12-lead ECG
    Gregg, Richard E.
    Babaeizadeh, Saeed
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (06) : 890 - 894
  • [37] Feasibility and validity of using deep learning to reconstruct 12-lead ECG from three-lead signals
    Wang, Liang-Hung
    Zou, Yu -Yi
    Xie, Chao-Xin
    Yang, Tao
    Abu, Patricia Angela R.
    JOURNAL OF ELECTROCARDIOLOGY, 2024, 84 : 27 - 31
  • [38] Sensitivity to noise and artifacts of the Mason-Likar 12-lead ECG and the EASI-derived 12-lead ECG for monitoring applications
    Thulin, A
    Pettersson, J
    Pahlm, O
    CRITICAL CARE MEDICINE, 2002, 30 (12) : A76 - A76
  • [39] Detection of Unicolor ECG Electrode Reversals in Standard 12-Lead ECG
    Jekova, Irena
    Leber, Remo
    Krasteva, Vessela
    Schmid, Ramun
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45
  • [40] Erratum to: A novel method based on convolutional neural networks for deriving standard 12-lead ECG from serial 3-lead ECG
    Lu-di Wang
    Wei Zhou
    Ying Xing
    Na Liu
    Mahmood Movahedipour
    Xiao-guang Zhou
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 750 - 750