Multi-source PV-battery DC microgrid operation mode and power allocation strategy based on two layer fuzzy controller

被引:0
|
作者
Pan, Hao [1 ]
Wang, Zhen [1 ]
Cheng, Peng [1 ]
Jia, Limin [2 ]
Li, Qingmin [3 ]
机构
[1] North China Elect Power Univ, China Inst Energy & Transportat Integrated Dev, Beijing, Peoples R China
[2] Beijing Jiaotong Univ, State Key Lab Adv Rail Autonomous Operat, Beijing, Peoples R China
[3] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewable, Renewable Energy Sources, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
adaptive control; fuzzy control; maximum power point trackers; micro grids; photovoltaic power systems; ENHANCEMENT; SYSTEM;
D O I
10.1049/gtd2.13345
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The conventional DC bus signaling (DBS) coordination control strategy for islanded DC microgrids (IDCMGs) faces challenges in coordinating multiple distributed generators (DGs) and fails to effectively incorporate the state of charge (SOC) information of the energy storage system, reducing system flexibility. In this article, a two-layer fuzzy control-based coordination strategy is proposed for multi-PV islanded DC microgrids. The first layer fuzzy logic controller (FLC) quantifies and selects the optimal system operating mode, adaptively adjusting the number of PV units operating in maximum power point tracking (MPPT) mode to manage system power surplus or deficit, thereby simplifying system design and enhancing flexibility. The second layer FLC adaptively adjusts the output of distributed energy sources based on SOC and current system conditions to better align the energy storage system's output with overall system operation, resulting in at least a 4% improvement in SOC level and effectively preventing overcharging or over-discharging issues seen in traditional control. Additionally, for PV units operating in droop mode, the droop coefficient is recalculated based on their maximum generation capacity under changing external conditions, thereby achieving more efficient power distribution and preventing system instability caused by power exceeding the limits of individual PV units. Finally, the effectiveness of the proposed control strategy is validated through RT-lab hardware-in-the-loop (HIL) simulations.
引用
收藏
页数:14
相关论文
共 43 条
  • [31] Power Allocation Strategy of DC Microgrid All Vanadium Redox Flow Battery Energy Storage System Based on A-SA-WOA Algorithm
    Fu H.
    Lu P.
    Zhang J.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (07): : 1826 - 1837
  • [32] Solar PV Fed DC Link Voltage For Fuzzy Logic Sliding Mode Controller Based UPQC To Improve The Dynamic Performance In Power Grid
    Himabindu, E.
    Krishna, D.
    Venkateshwarlu, S.
    Reddy, Kavitha Chenna
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2025, 28 (05): : 969 - 978
  • [33] GWO Algorithm Based Fuzzy-PID Controller with Derivative Filter for Load Frequency Control of Multi-Source Hydrothermal Power System
    Kumar, Amit
    Suhag, Sathans
    PROCEEDINGS OF THE 2017 THE 5TH INTERNATIONAL CONFERENCE ON CONTROL, MECHATRONICS AND AUTOMATION (ICCMA 2017), 2017, : 50 - 55
  • [34] Zero-Vector-Regulation-Based Closed-Loop Power Distribution Strategy for Dual-DC-Port DC-AC Converter-Connected PV-Battery Hybrid Systems
    Liu, Lijie
    Zhou, Dehong
    Zou, Jianxiao
    Wang, Weijun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (06) : 6956 - 6968
  • [35] An Optimal Multi-mode Power Allocation Strategy for Fuel Cell and Battery Hybrid System Based on Particle Swarm Optimization
    Wang, Siyu
    Yang, Duo
    Fu, Hanwen
    Zhong, Yazhe
    2023 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA, I&CPS ASIA, 2023, : 1739 - 1744
  • [36] Robust fuzzy sliding mode controller design for voltage source converter high-voltage DC based interconnected power system
    Nayak, N.
    Routray, S.K.R.
    Rout, P.K.
    Australian Journal of Electrical and Electronics Engineering, 2014, 11 (04): : 421 - 433
  • [37] Gravitational Search Algorithm (GSA) Based PID Controller Design for Two Area Multi-Source Power System Load Frequency Control (LFC)
    Safi, Shah Jahan
    Tezcan, Suleyman Sungur
    Eke, Ibrahim
    Farhad, Zakirhussain
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2018, 31 (01): : 139 - 153
  • [38] Reliability evaluation of an aggregate power conversion unit in the off-grid PV-battery-based DC microgrid from local energy communities under dynamic and transient operation
    Kuo, Tsai-Chi
    Trang Thi Pham
    Duong Minh Bui
    Phuc Duy Le
    Tan Luong Van
    Huang, Po-Tsang
    ENERGY REPORTS, 2022, 8 : 5688 - 5726
  • [39] Bull-lion Optimization-based Proportional Integrated Derivative controller for regulating frequency in Two-Area Multi-Source power system
    Singh, Balvender
    Bishnoi, S. K.
    ADVANCES IN ENGINEERING SOFTWARE, 2023, 181
  • [40] Two-Layer Coordinated Energy Management Method in the Smart Distribution Network including Multi-Microgrid Based on the Hybrid Flexible and Securable Operation Strategy
    Sabzalian, Mohammad Hosein
    Pirouzi, Sasan
    Aredes, Mauricio
    Franca, Bruno Wanderley
    Cunha, Ana Carolina
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2022, 2022