Comparison of dynamic hip screw with anti-rotation screw and femoral neck system internal fixation for the treatment of garden II-IV type femoral neck fractures

被引:0
|
作者
Hong, Haisen [1 ]
Sha, Mo [1 ]
Chen, Zhangxin [1 ]
Li, Yanwei [1 ]
Kang, Liangqi [1 ]
机构
[1] Xiamen Univ, Hosp 909, Sch Med, Dept Orthoped, Zhangzhou 363000, Fujian, Peoples R China
关键词
Femoral neck fractures; Garden II-IV classification; dynamic hip screw (DHS); anti-rotation screw; femoral neck system (FNS); internal fixation;
D O I
10.3233/THC-231547
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Femoral neck fractures, which are fractures occurring from the femoral head to the base of the femoral neck, are prevalent in the elderly population. With the progression of societal aging, the incidence of femoral neck fractures has been steadily increasing, making it a significant global issue that urgently needs to be addressed. OBJECTIVE: To compare the efficacy and safety of dynamic hip screw (DHS) with anti-rotation screw and femoral neck system (FNS) internal fixation for the treatment of Garden II-IV type femoral neck fractures. METHODS: A total of 90 patients with Garden II-IV type femoral neck fractures were randomly assigned to either the control group (n = 45) treated with DHS and anti-rotation screw or the experimental group (n = 45) treated with FNS. Surgical outcomes, including incision size, blood loss, operation time, fluoroscopy frequency, and fracture healing time, were compared. Postoperative complication rates, reoperation rates, Harris scores, and visual analogue scale (VAS) scores were also assessed. RESULTS: The experimental group demonstrated significantly reduced incision length, blood loss, operation time, and fluoroscopy frequency compared to the control group (P < 0.01). No significant differences were observed in fracture healing time, Garden classification, or fracture reduction outcomes between the two groups (P > 0.05). At 6 months post-treatment, both groups showed significant improvements in Harris scores and VAS scores compared to pre-treatment (P < 0.05), with no significant differences between the groups (P > 0.05). The rates of internal fixation failure, nonunion, and avascular necrosis of the femoral head, as well as overall incidence of postoperative complications and reoperation rates, showed no significant differences between the two groups (P > 0.05). CONCLUSIONS: Both DHS with anti-rotation screw and FNS internal fixation demonstrated comparable efficacy and safety profiles in the treatment of Garden II-IV type femoral neck fractures. The experimental group showed advantages in terms of reduced incision length, blood loss, operation time, and fluoroscopy frequency, while maintaining similar clinical outcomes and complication rates.
引用
收藏
页码:4009 / 4017
页数:9
相关论文
共 50 条
  • [41] Comparison of clinical outcomes with proximal femoral nail anti-rotation versus dynamic hip screw for unstable intertrochanteric femoral fractures: A meta-analysis
    Zhang, Cong
    Chen, Zhangxin
    Wang, Mengyuan
    Chen, Wei
    Ding, Zhenqi
    MEDICINE, 2023, 102 (06) : E32920
  • [42] Fixed angle device comparison in young femoral neck fractures: Dynamic hip screw vs dynamic helical hip system
    Marchand, Lucas S.
    Butler, Bennet
    McKegg, Phillip
    DeLeon, Genaro
    O'Hara, Nathan N.
    Lebrun, Christopher T.
    Sciadini, Marcus F.
    Nascone, Jason W.
    O'Toole, Robert, V
    Slobogean, Gerard M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 590 - 595
  • [43] HIP COMPRESSION SCREW VERSUS NAIL PLATE FIXATION OF FEMORAL-NECK FRACTURES
    BENUM, P
    SVENNINGSEN, S
    NESSE, O
    FURSET, OI
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03): : 387 - 388
  • [44] Treatment of femoral neck fractures in Hungary with the Manninger screw
    Fekete, K
    Laczkó, T
    Flóris, I
    Cserháti, P
    Tasnádi, L
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 : S19 - S23
  • [45] Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Bing
    Jin, Lin
    Lin, Zhe
    Hou, Zhiyong
    Zhang, Yingze
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 557 - 568
  • [46] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Zhang, Baokun
    Liu, Jingwen
    Zhu, Yi
    Zhang, Wei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1949 - 1955
  • [47] Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures
    Xu, Xiangyu
    Fan, Jixing
    Zhou, Fang
    Lv, Yang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Yang, Zhongwei
    Hou, Guojin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S28 - S35
  • [48] Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures
    Xu, Xiangyu
    Fan, Jixing
    Zhou, Fang
    Lv, Yang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Yang, Zhongwei
    Hou, Guojin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S28 - S35
  • [49] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Baokun Zhang
    Jingwen Liu
    Yi Zhu
    Wei Zhang
    International Orthopaedics, 2018, 42 : 1949 - 1955
  • [50] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834