Free-running 5D whole-heart MRI for isotropic cardiac function measurements at 3T without contrast agents

被引:0
|
作者
Ogier, Augustin C. [1 ,2 ]
Quesada, Isabel Monton [1 ,2 ]
Sieber, Xavier [1 ,2 ]
Calarnou, Pauline [1 ,2 ]
Ledoux, Jean-Baptiste [1 ,2 ,3 ]
Milani, Bastien [1 ,2 ]
Antiochos, Panagiotis [2 ,4 ]
Schwitter, Juerg [2 ,4 ]
Roy, Christopher W. [1 ,2 ]
Yerly, Jerome [1 ,2 ,3 ]
Stuber, Matthias [1 ,2 ,3 ]
van Heeswijk, Ruud B. [1 ,2 ]
机构
[1] Lausanne Univ Hosp CHUV, Dept Radiol, Rue Bugnon 46,BH 8-84, CH-1011 Lausanne, Switzerland
[2] Univ Lausanne UNIL, Lausanne, Switzerland
[3] CIBM Ctr Biomed Imaging, Lausanne, Switzerland
[4] Lausanne Univ Hosp CHUV, Heart & Vessel Dept, Lausanne, Switzerland
关键词
3T; 5D whole-heart MRI; compressed sensing; contrast-agent-free; free-running; non-rigid motion correction; T-2 preparation pulse; T-2; PREPARATION; CORONARY; ANGIOGRAPHY;
D O I
10.1002/mrm.30469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To optimize and characterize an interrupted 5D free-running framework at 3 T for detailed cardiac function assessment without the use of breath holding or contrast agents. Methods: A free-running 3D radial gradient echo sequence was periodically interrupted with a T2 preparation and a recovery module to optimize native blood-to-myocardium contrast at 3 T. Lipid signal was suppressed using a numerically optimized water-excitation RF pulse to reduce lipid streaking artifacts and to improve overall image quality. Optimal acquisition parameters were established for a 5-min scan time using extended phase graph simulations. A compressed sensing-based reconstruction incorporating cardiac and respiratory inter-bin deformation fields was employed to generate 5D images of the whole heart. The sharpness and contrast between the left ventricular blood pool and myocardium, along with the functional measurements of the left ventricle from the 5D datasets, were compared to routine 2D cine imaging in 16 healthy volunteers and three patients referred for clinically indicated CMR. Results: The proposed method resulted in lower contrast (0.57 +/- 0.12 vs. 2.09 +/- 0.74,p <0.001) and sharpness (3.76 +/- 1.11 mm vs. 2.74 +/- 0.95 mm, p <0.001), but enabled similar left-ventricle ejection fraction assessment (bias = 1.3%, limits of agreement = [-3.3%, 5.9%], intraclass correlation coefficient = 0.87,p = 0.03) with high reproducibility compared to 2D cine. Conclusion: The proposed contrast-free, interrupted free-running 5D imaging provides left ventricular functional assessments comparable to 2D cine at 3 T, while offering an improved patient experience through shorter scan times and free breathing.
引用
收藏
页码:2386 / 2400
页数:15
相关论文
共 30 条
  • [21] Use of 2D Sensitivity Encoding for Slow-Infusion Contrast-Enhanced Isotropic 3-T Whole-Heart Coronary MR Angiography
    Yu, Jing
    Paetsch, Ingo
    Schnackenburg, Bernhard
    Fleck, Eckart
    Weiss, Robert G.
    Stuber, Matthias
    Jahnke, Cosima
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : 374 - 382
  • [22] Whole-Heart Cine MRI in a Single Breath-Hold - A Compressed Sensing Accelerated 3D Acquisition Technique for Assessment of Cardiac Function
    Wech, T.
    Pickl, W.
    Tran-Gia, J.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Koestler, H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (01): : 37 - 41
  • [23] 5D Flow MRI: A Fully Self-gated, Free-running Framework for Cardiac and Respiratory Motion-resolved 3D Hemodynamics(vol 2, page e200219, year 2020)
    Ma, Liliana E.
    Yerly, Jerome
    Piccini, Davide
    Di Sopra, Lorenzo
    Roy, Christopher W.
    Carr, James C.
    Rigsby, Cynthia K.
    Kim, Daniel
    Stuber, Matthias
    Markl, Michael
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (03):
  • [24] Self-navigated free-breathing isotropic 3D whole heart MRI for the characterization of complex cardiac anatomy in patients with congenital heart malformations
    Monney, P.
    Piccini, D.
    Rutz, T.
    Vincenti, G.
    Koestner, S.
    Stuber, M.
    Schwitter, J.
    EUROPEAN HEART JOURNAL, 2013, 34 : 381 - 382
  • [25] Self-navigated free-breathing isotropic 3D whole heart MRI for the characterization of complex cardiac anatomy in patients with congenital heart malformations
    Pierre Monney
    Davide Piccini
    Gabriella Vincenti
    Arne Littmann
    Michael O Zenge
    Simon C Koestner
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [26] Fast, heart-rate independent, whole-heart, free-breathing, three-dimensional myocardial BOLD MRI at 3T with simultaneous 13N-ammonia PET validation in canines
    Yang H.-J.
    Dey D.
    Sykes J.M.
    Butler J.
    Sharif B.
    Li D.
    Tsaftaris S.
    Bi X.
    Slomka P.
    Prato F.S.
    Dharmakumar R.
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [27] Fast, Free-breathing, Heart-rate Independent Quantitative Myocardial Oxygenation MRI at 3T for Detecting Ischemic Heart Disease Without Contrast Agents With Simultaneous 13N-Ammonia PET Validation
    Yang, Hsin-Jung
    Dey, Damini
    Syskes, Jane
    Butler, John
    Bi, Xiaoming
    Kali, Avinash
    Cokic, Ivan
    Sharif, Behzad
    Tsaftaris, Sotirios
    Li, Debiao
    Slomka, Piotr
    Prato, Frank
    Dharmakumar, Rohan
    CIRCULATION, 2015, 132
  • [28] Non-contrast free-breathing 2D CINE compressed SENSE T1-TFE cardiovascular MRI at 3T in sedated young children for assessment of congenital heart disease
    Ristow, Inka
    Hancken-Pauschinger, Caroline-Viktoria
    Zhang, Shuo
    Stark, Maria
    Kaul, Michael G.
    Rickers, Carsten
    Herrmann, Jochen
    Adam, Gerhard
    Bannas, Peter
    Well, Lennart
    Weinrich, Julius Matthias
    PLOS ONE, 2024, 19 (02):
  • [29] Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T
    Isaak, Alexander
    Mesropyan, Narine
    Hart, Christopher
    Zhang, Shuo
    Kravchenko, Dmitrij
    Endler, Christoph
    Katemann, Christoph
    Weber, Oliver
    Pieper, Claus C.
    Kuetting, Daniel
    Attenberger, Ulrike
    Dabir, Darius
    Luetkens, Julian A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [30] Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T
    Alexander Isaak
    Narine Mesropyan
    Christopher Hart
    Shuo Zhang
    Dmitrij Kravchenko
    Christoph Endler
    Christoph Katemann
    Oliver Weber
    Claus C. Pieper
    Daniel Kuetting
    Ulrike Attenberger
    Darius Dabir
    Julian A. Luetkens
    Journal of Cardiovascular Magnetic Resonance, 24