Inductive Voltage Transformer Behaviour in the Frequency Range from 9 kHz up to 150 kHz

被引:0
|
作者
Crotti, Gabriella [1 ]
D'Avanzo, Giovanni [2 ]
Delle Femine, Antonio [3 ]
Gallo, Daniele [3 ]
Giordano, Domenico [1 ]
Iodice, Claudio [3 ]
Landi, Carmine [3 ]
Letizia, Palma Sara [1 ]
Luiso, Mario [3 ]
Palladini, Daniele [2 ]
机构
[1] Ist Nazl Ric Metrol INRIM, Turin, Italy
[2] Ric Sistema Energet RSE SpA, Milan, Italy
[3] Univ Campania Luigi Vanvitelli, Aversa, CE, Italy
关键词
Instrument Transformers; Frequency Characterization; Nonlinear Behaviour; Medium Voltage; High Frequency Distortion; FERRORESONANCE;
D O I
10.1109/AMPS62611.2024.10706667
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the widespread diffusion of power converters able to be directly connected to Medium Voltage (MV) grids, there is the need to measure high frequency distortion, that is from 9 kHz up to 150 kHz. Inductive Voltage Transformers (VTs) are still the most installed voltage transducers in the power systems, but the knowledge of their behaviour in this frequency range is still an open issue. The aim of this paper is to analyse the behaviour of inductive VTs from 9 kHz up to 150 kHz. A commercial VT has been tested and the results show that the nonlinearity of the iron core can influence the behaviour of inductive VTs at least up to 150 kHz.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Analysis of High Frequency Harmonics in Distribution Networks: 9-150 kHz
    Yaghoobi, Jalil
    Zare, Firuz
    Rehman, Tayyab
    Rathnayake, Hansika
    2019 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2019, : 1229 - 1234
  • [42] Development of a test bench to investigate the breakdown voltage of insulation oil in a frequency range between 1 kHz and 10 kHz
    Moeller, R.
    Soppe, B.
    Schnettler, A.
    2017 IEEE SECOND INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2017, : 160 - 165
  • [43] A New High Frequency Grid Impedance Estimation Technique for the Frequency Range of 2 to 150 kHz
    AlyanNezhadi, M. M.
    Hassanpour, H.
    Zare, F.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2018, 31 (10): : 1666 - 1674
  • [44] Interferences in AC-DC LED Drivers Exposed to Voltage Disturbances in the Frequency Range 2-150 kHz
    Sakar, Selcuk
    Ronnberg, Sarah
    Bollen, Math
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (11) : 11171 - 11181
  • [45] Measurement of current taken by fluorescent lights in the frequency range 2-150 kHz
    Larsson, E. O. A.
    Lundmark, C. A.
    Bollen, M. H. J.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 1231 - +
  • [46] Measures for the limitation of voltage distortion in the kHz range
    Krueger, Kurt
    Sonnenschein, Martin
    Unger, Christian
    Zurowski, Rainer
    IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 277 - 281
  • [47] Influence of measurement setup on the emission of devices in the frequency range 2-150 kHz
    Agudelo-Martinez, Daniel
    Pavas, Andres
    Blanco, Ana Maria
    Stiegler, Robert
    Meyer, Jan
    2019 IEEE MILAN POWERTECH, 2019,
  • [48] OBSERVATIONS OF THE RADIO NOISE BACKGROUND IN THE FREQUENCY-RANGE 150-180 KHZ
    KNOWLES, SH
    KELLY, FJ
    WALTMAN, WB
    ODENWALD, S
    RADIO SCIENCE, 1985, 20 (03) : 519 - 527
  • [49] An Objective and Subjective Study of Noise Exposure within the Frequency Range from 10 kHz to 40 kHz
    Smagowska, Bozena
    ARCHIVES OF ACOUSTICS, 2013, 38 (04) : 559 - 563
  • [50] The extrapolation factor for PLC radiation measurements in the 150-500 kHz frequency range
    Waechter, Markus
    Koch, Michael
    Schwing, Christoph
    Hirsch, Holger
    2013 17TH IEEE INTERNATIONAL SYMPOSIUM ON POWER LINE COMMUNICATIONS AND ITS APPLICATIONS (ISPLC), 2013, : 220 - 224