Evaluation of Pelvic MRI-to-CT Deformable Registration for Adaptive MR-Guided Particle Therapy

被引:0
|
作者
Pestana, Rita [1 ,2 ,3 ,4 ]
Seidensaal, Katharina [1 ,2 ,3 ]
Beyer, Cedric [1 ,2 ,3 ]
Debus, Juergen [1 ,2 ,3 ,5 ,6 ,7 ]
Klueter, Sebastian [1 ,2 ,3 ]
Bauer, Julia [1 ,2 ,3 ]
机构
[1] Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[4] Heidelberg Univ, Heidelberg, Germany
[5] DKFZ, Natl Ctr Tumor Dis NCT, NCT Heidelberg, Heidelberg, Germany
[6] Heidelberg Univ Hosp, Heidelberg, Germany
[7] German Canc Res Ctr DKFZ Heidelberg, Clin Cooperat Unit Radiat Oncol, Heidelberg, Germany
关键词
Adaptive therapy; Particle therapy; Magnetic resonance; Imaging; Deformable image registration; IMAGE REGISTRATION; RADIOTHERAPY; ALGORITHMS;
D O I
10.1016/j.ijpt.2024.100636
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We aim to assess the magnetic resonance imaging (MRI)-to-CT deformable image registration (DIR) quality of our treatment planning system in the pelvic region as the first step of an online MRI-guided particle therapy clinical workflow. Materials and Methods: Using 2 different DIR algorithms, ANAtomically CONstrained Deformation Algorithm (ANACONDA), the DIR algorithm incorporated in RayStation, and Elastix, an open-source registration software, we retrospectively assessed the quality of the deformed CT (dCT) generation in the pelvic region for 5 patients. T1- and T2-weighted daily control MRI acquired prior to treatment delivery were used for the DIR. We compared the contours automatically mapped on the dCT against the manual contours on the MRI (ground truth) by calculating the Dice similarity coefficients and mean distances to the agreement for organs at risk, targets, and outer contour. We assessed the dosimetric impact of the DIR on the clinical treatment plans, comparing the dosevolume histograms and the value of the clinical goals achieved for each dCT. The water equivalent path lengths and dose range 80% (R80%) maps were compared by casting on the beams' eye view. Results: The T1 sequences performed better for the DIR with ANACONDA compared against the T2. ANACONDA's performance agreed with Elastix. The bladder and rectum led to the worst agreement. For the remaining structures analyzed, Dice similarity coefficients above 0.80 were obtained. Maximum median deviations of 7.1 and 2.1 mm were observed for water equivalent path lengths and R80%, respectively, on the PTV. Conclusion: This work shows a good agreement on the DIR quality achieved with ANACONDA for the structures in the beams' path. By comparing the R80% generated with ANACONDA and Elastix, we give a first quantification of the uncertainties to be considered in an online MRI-guided particle therapy workflow for pelvic treatment.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] On the accuracy of bulk synthetic CT for MR-guided online adaptive radiotherapy
    Davide Cusumano
    Lorenzo Placidi
    Stefania Teodoli
    Luca Boldrini
    Francesca Greco
    Silvia Longo
    Francesco Cellini
    Nicola Dinapoli
    Vincenzo Valentini
    Marco De Spirito
    Luigi Azario
    La radiologia medica, 2020, 125 : 157 - 164
  • [22] Evaluation of Delivered Dose Using Synthetic CT for MR-Guided and CT-Guided Radiotherapy
    Wang, H.
    MEDICAL PHYSICS, 2022, 49 (06) : E756 - E757
  • [23] Improving Deformable Image Registration and Segmentation Using a Combined Preprocessing Pipeline and Multiple Input Strategy for Online Adaptive MR-Guided Radiotherapy
    Zhang, Y.
    Paulson, E. S.
    Ahunbay, E. E.
    Mickevicius, N.
    Hall, W. A.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S30 - S30
  • [24] Retrospective Evaluation of Decision-Making for Pancreatic Stereotactic MR-Guided Adaptive Radiation Therapy
    Jiang, N.
    Tyran, M.
    Cao, M.
    Raldow, A.
    Lamb, J. M.
    Low, D.
    Steinberg, M. L.
    Lee, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S209 - S210
  • [25] Oncology Scan-Improvements in Dose Calculation, Deformable Registration, and MR-Guided Radiation Delivery COMMENTS
    Vargo, John A.
    Flickinger, John C.
    Beriwal, Sushil
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 398 - 399
  • [26] Non-rigid MR-CT image registration for MR-Guided Liver Cancer Surgery
    Chen, Y. -W.
    Xu, R.
    Tang, S. -Y.
    Morikawa, S.
    Kurumi, Y.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1756 - +
  • [27] Evaluation of whole-body MR to CT deformable image registration
    Akbarzadeh, A.
    Gutierrez, D.
    Baskin, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Loevblad, K. O.
    Zaidi, H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 238 - 253
  • [28] Region-Adaptive Deformable Registration of CT/MRI Pelvic Images via Learning-Based Image Synthesis
    Cao, Xiaohuan
    Yang, Jianhua
    Gao, Yaozong
    Wang, Qian
    Shen, Dinggang
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2018, 27 (07) : 3500 - 3512
  • [29] A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases
    Cusumano, Davide
    Lenkowicz, Jacopo
    Votta, Claudio
    Boldrini, Luca
    Placidi, Lorenzo
    Catucci, Francesco
    Dinapoli, Nicola
    Antonelli, Marco Valerio
    Romano, Angela
    De Luca, Viola
    Chiloiro, Giuditta
    Indovina, Luca
    Valentini, Vincenzo
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 205 - 212
  • [30] Oncology Scan-Improvements in Dose Calculation, Deformable Registration, and MR-Guided Radiation Delivery Reply
    Puthawala, Ajmel
    Syed, A. M. Nisar
    Sharma, Anil
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 399 - 400