Optimized analysis of magnetic noise based on residual magnetization measurements of magnetic shielding devices

被引:0
|
作者
Liu, Wei [1 ,2 ]
Xu, Xueping [1 ,2 ]
Zhao, Zhenkai [1 ,2 ]
Wu, Weiwei [1 ,2 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Minist Educ, Key Lab Ultraweak Magnet Field Measurement Technol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic shielding; Residual magnetization; Magnetic noise; Anisotropy; Nanocrystalline;
D O I
10.1016/j.sna.2025.116372
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic shielding devices (MSDs) provide a low-noise ultra-weak magnetic environment for magnetoencephalography (MEG) measurements. Reducing the residual magnetization (RM) of MSDs is critical for highsensitivity measurements. Considering the anisotropic properties of laminated nanocrystalline materials, we propose a magnetic noise calculation model that accounts for anisotropy. This paper further introduces an RM measurement method for MSDs based on sensors and finite element models to investigate the effect of RM on magnetic noise. Based on the computed conversion matrix and the magnetic flux density matrix measured by sensors, calculate the RM of the MSD. The magnetic noise and RM at different points are tested and normalized, showing that the RM correlates with the trend of magnetic noise, with decision coefficients greater than 0.99. The central point along the Y-axis of the nanocrystalline magnetic shielding device (NMSD) is selected for magnetic noise simulation and experimentation. The discrepancy between the simulation and experimental results is 3.42 %, validating the effectiveness of the proposed model. This study provides an essential basis for optimizing the magnetic noise of MSDs for ultra-high-sensitivity atomic sensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Probing magnetization dynamics of strongly interacting magnetic nanoparticles through magnetoresistive current noise measurements
    Taub, Nurit
    Markovich, Gil
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (48)
  • [42] Lagrangian Modeling of the Magnetization and the Magnetic Torque on Assembled Soft-Magnetic MEMS Devices for Fast Computation and Analysis
    Nagy, Zoltan
    Nelson, Bradley J.
    IEEE TRANSACTIONS ON ROBOTICS, 2012, 28 (04) : 787 - 797
  • [43] Application of magnetic Barkhausen noise for residual stress analysis - Consideration of the microstructure
    Schuster, Simone
    Dertinger, Laura
    Dapprich, Dominik
    Gibmeier, Jens
    MATERIALS TESTING, 2018, 60 (06) : 545 - 552
  • [44] Local Magnetic Shielding of MRI Devices by Superconductive Materials
    Zucca, Mauro
    Chiampi, Mario
    Gozzelino, Laura
    Zilberti, Luca
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (10) : 4278 - 4281
  • [45] PRESSURE MEASUREMENTS IN MAGNETIC FUSION DEVICES
    DYLLA, HF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1982, 20 (04): : 1166 - 1167
  • [46] PRESSURE MEASUREMENTS IN MAGNETIC FUSION DEVICES
    DYLLA, HF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1982, 20 (02): : 119 - 128
  • [47] DEVELOPMENT OF A NEW DEVICE FOR MAGNETIC STRUCTUROSCOPES BASED FEATURES RESIDUAL MAGNETIZATION HYSTERESIS AT PULSED MAGNETIZATION REVERSAL PRODUCTS
    Matyuk, V. F.
    Melgui, M. A.
    DEVICES AND METHODS OF MEASUREMENTS, 2011, (01): : 17 - 24
  • [48] MAGNETIC MEASUREMENTS ON INSERTION DEVICES AT NSLS
    DECKER, G
    GALAYDA, J
    SOLOMON, L
    KITAMURA, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1845 - 1848
  • [49] Segmented Contracted Basis Sets Optimized for Nuclear Magnetic Shielding
    Jensen, Frank
    JOURNAL OF CHEMICAL THEORY AND COMPUTATION, 2015, 11 (01) : 132 - 138
  • [50] Model based computation of electromagnetic forces in magnetic confinement toroidal devices by using magnetic measurements
    Abate, D.
    Marchiori, G.
    Berton, G.
    Bonotto, M.
    Cordaro, L.
    Grando, L.
    Bettini, P.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2021, 63 (07)