Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography

被引:0
|
作者
Pretze, Marc [1 ]
Wendrich, Jan [2 ]
Hartmann, Holger [1 ]
Freudenberg, Robert [1 ]
Bundschuh, Ralph A. [1 ]
Kotzerke, Jorg [1 ]
Michler, Enrico [1 ]
机构
[1] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Nucl Med, Fetscherstr 74, D-01307 Dresden, Germany
[2] Eckert & Ziegler Eurotope, D-13125 Berlin, Germany
关键词
Pb-212; Ac-225; PSMA; TATE; TOC; thin-layer chromatography (TLC); quality control; THERAPY; AC-225;
D O I
10.3390/ph18010026
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
(1) Background: Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of 212Pb- and 225Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the Pb-212/Ac-225-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) Methods: The routine alpha detection on thin-layer chromatograms (TLC) of Pb-212- and( 225)Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) Results: For Ac-225, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken. That is, if the TLC probe was taken 24 h after radiosynthesis, the true value of the RCP was not measured until 5 h after TLC development. For Pb-212-labelled peptides, the probe sampling did not have a high impact on the value of the RCP for the MiniScanPRO+ and AR-2000. A difference was observed when measuring TLC with the AR-2000 in different modes; (4) Conclusions: The MiniScanPRO+ is fast, does not require additional equipment and can also measure the gamma spectrum, which may be important for some radiopharmaceutical production sites and regulatory authorities. The AR-2000 has a better signal-to-noise ratio, and this eliminates the need for additional waiting time after TLC development.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] COMPARISON OF THIN-LAYER AND COLUMN CHROMATOGRAPHY
    PERRY, SG
    STEWART, NM
    AMOS, R
    APPLIED SPECTROSCOPY, 1968, 22 (03) : 227 - &
  • [2] THIN-LAYER CHROMATOGRAPHY FLUORESCENT DETECTION
    CAMPBELL, BH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 18 - AGFD
  • [3] DETECTION OF GINKGOLIDES BY THIN-LAYER CHROMATOGRAPHY
    TALLEVI, SG
    KURZ, WGW
    JOURNAL OF NATURAL PRODUCTS, 1991, 54 (02): : 624 - 625
  • [4] DETECTION OF STEROIDS IN THIN-LAYER CHROMATOGRAPHY
    KRITCHEVSKY, D
    TEPPER, SA
    JOURNAL OF CHROMATOGRAPHY, 1968, 37 (02): : 361 - +
  • [5] Bioautography detection in thin-layer chromatography
    Choma, Irena M.
    Grzelak, Edyta M.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (19) : 2684 - 2691
  • [6] Study on preparation of a thin film type of ZnS(Ag) scintillator sheet for alpha-ray detection
    Seo, Bum-Kyoung
    Jung, Yeon-Hee
    Kim, Gye-Hong
    Lee, Kune-Woo
    Jung, Chong-Hun
    Han, Myeong-Jin
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (05): : 389 - 393
  • [7] Comparison of the Limit of Detection of Paracetamol, Propyphenazone, and Caffeine Analyzed Using Thin-Layer Chromatography and High-Performance Thin-Layer Chromatography
    Bober-Majnusz, Katarzyna
    Pyka-Pajak, Alina
    PROCESSES, 2024, 12 (06)
  • [8] COMPARISON OF THIN-LAYER CHROMATOGRAPHY AND LIQUID-CHROMATOGRAPHY
    SHERMA, J
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1991, 74 (03): : 435 - 437
  • [9] Detection of Actaea racemosa adulteration by thin-layer chromatography and combined thin-layer chromatography-bioluminescence
    Verbitski, Sheryl M.
    Gourdin, Gerald T.
    Ikenouye, Larissa M.
    McChesney, James D.
    Hildreth, Jana
    JOURNAL OF AOAC INTERNATIONAL, 2008, 91 (02) : 268 - 275
  • [10] DETECTION OF ALPHA-GLYCOL GROUPINGS IN THIN-LAYER CHROMATOGRAPHY ON SILICA GEL
    BERGELSON, L
    DIATLOVI.EV
    VORONKOVA, VV
    DOKLADY AKADEMII NAUK SSSR, 1961, 141 (01): : 84 - &