FEM-based Parametric Optimization of a Measurement Setup for Sensitivity Improvement in Insulin Absorption Assessment

被引:0
|
作者
Manzo, Rosanna [1 ]
Arpaia, Pasquale [2 ]
Balato, Marco [2 ]
Cuneo, Davide [2 ]
Mancino, Francesca [2 ]
Minucci, Simone [3 ]
Moccaldi, Nicola [4 ]
Petrarca, Carlo [2 ]
机构
[1] Univ Naples Federico II, Dept Publ Hlth & Prevent Med, Naples, Italy
[2] Univ Naples Federico II, Dept Elect Engn & Informat Technol DIETI, Naples, Italy
[3] Univ Tuscia, Dept Econ Engn Soc & Business Org DEIm, Viterbo, Italy
[4] Univ Salento, Dept Engn Innovat, Lecce, Italy
来源
2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024 | 2024年
关键词
insulin absorption measurement; FEM; parametric optimization; Taguchi experimental plan; ADULTS; AGE;
D O I
10.1109/I2MTC60896.2024.10560806
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A finite element model of human abdominal tissue for improving the percentage relative sensitivity of a bioimpedance spectroscopy-based method for insulin absorption measurements was proposed. The model was realised by considering only four layers of the abdomen (dry and wet skin, fat, and muscle) electrically characterized with models already validated in the scientific literature. A parametric optimization was carried out to maximize the relative sensitivity of the proposed measurement method. In particular, a fractional factorial plan approach (Taguchi L18) was implemented to analyze different setups of the measurement apparatus in terms of signal frequency and dimensions and electrodes mutual distance. ANOM and ANOVA were conducted to assess the impact of each parameter on the measurement percentage relative sensitivity. The analysis revealed that the distance between the amperometric and voltammetric electrode as the most influencing factor on the percentage relative sensitivity. Considering the constraints related to the direction of the total current density field and the electrodes positioning, the value of the distance maximizing the sensitivity results the optimum one. A range of percentage relative sensitivity variation of 29.25 % was obtained in the experimental plan investigated. The highest percentage relative sensitivity of 29.78 % was obtained with the optimum measurement setup, in the case of 100 ml insulin injected. An improvement in percentage relative sensitivity by a factor of 30 was achieved with the optimum measurement setup with respect to the measurement setup proposed in literature.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Global-Simplex Optimization Algorithm Applied to FEM-Based Optimal Design of Electric Machine
    Han, Wonseok
    Chan Van Dang
    Kim, Jong-Wook
    Kim, Yong-Jae
    Jung, Sang-Yong
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (06)
  • [32] A FEM-Based Optimization Method for Driving Frequency of Contactless Magnetoelastic Torque Sensors in Steel Shafts
    Ostaszewska-Lizewska, Anna
    Nowicki, Michal
    Szewczyk, Roman
    Malinen, Mika
    MATERIALS, 2021, 14 (17)
  • [33] Parametric study on the interface pullout strength of the vertebral body replacement cage using FEM-based Taguchi methods
    Hsu, Wen-Hsien
    Chao, Ching-Kong
    Hsu, Hsi-Ching
    Lin, Jinn
    Hsu, Ching-Chi
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (03) : 287 - 294
  • [34] FEM-Based Simulative Study for Multi-Response Optimization of Powder Bed Fusion Process
    Sood, Anoop Kumar
    Equbal, Azhar
    Khan, Zahid A.
    Badruddin, Irfan Anjum
    Hussien, Mohamed
    MATHEMATICS, 2022, 10 (14)
  • [35] FEM-Based Compression Fracture Risk Assessment in Osteoporotic Lumbar Vertebra L1
    Maknickas, Algirdas
    Alekna, Vidmantas
    Ardatov, Oleg
    Chabarova, Olga
    Zabulionis, Darius
    Tamulaitiene, Marija
    Kacianauskas, Rimantas
    APPLIED SCIENCES-BASEL, 2019, 9 (15):
  • [36] A Novel Design Space Decomposition Technique to Accelerate FEM-Based Electromagnetic Topology Optimization for Waveguide Structures
    Zhang, Jiali
    Jin, Jing
    Li, Xiaolong
    Feng, Feng
    Liu, Wei
    Zhang, Wei
    Ma, Kaixue
    Zhang, Qi-Jun
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2024, 72 (04) : 2234 - 2252
  • [37] Efficient FEM-Based EM Optimization Technique Using Combined Lagrangian Method With Newton's Method
    Feng, Feng
    Zhang, Jianan
    Jin, Jing
    Na, Weicong
    Yan, Shuxia
    Zhang, Qi-Jun
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2020, 68 (06) : 2194 - 2205
  • [38] FEM-based design and analysis of a smart cutting tool with internal cooling for cutting temperature measurement and control
    Shu, Shengrong
    Ding, Hui
    Chen, Shijin
    Cheng, Kai
    ADVANCED MATERIALS AND PROCESS TECHNOLOGY, PTS 1-3, 2012, 217-219 : 1874 - 1879
  • [39] A New FEM-based Brain Tissue Model for Neurosurgical Simulation Using the Optimization Implicit Euler Method
    Hou, Wenguo
    Liu, Peter X.
    Zheng, Minhua
    Liu, Shichao
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 8578 - 8582
  • [40] FEM-based parametric optimum design of a traveling-wave type bar-like ultrasonic motor stator
    Zhang, Jian-Tao
    Zhu, Hua
    Zhao, Chun-Sheng
    Zhendong yu Chongji/Journal of Vibration and Shock, 2009, 28 (07): : 122 - 125