Intra-Aneurysmal High-Resolution 4D MR Flow Imaging for Hemodynamic Imaging Markers in Intracranial Aneurysm Instability

被引:0
|
作者
van Tuijl, R. J. [1 ,2 ]
den Hertog, C. S. [3 ]
Timmins, K. M. [1 ]
Velthuis, B. K. [1 ]
van Ooij, P. [4 ,5 ]
Zwanenburg, J. J. M. [2 ]
Ruigrok, Y. M. [3 ]
van der Schaaf, I. C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Translat Neuroimaging Grp, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Univ Med Ctr Utrecht Brain Ctr, UMC Utrecht Brain Ctr, Dept Neurol & Neurosurg, Utrecht, Netherlands
[4] Amsterdam Univ Med Ctr Locat AMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[5] Univ Med Ctr Utrecht, Dept Pediat Cardiol, Utrecht, Netherlands
基金
欧洲研究理事会;
关键词
WALL SHEAR-STRESS; ENHANCEMENT;
D O I
10.3174/ajnr.A8380
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Prediction of aneurysm instability is crucial to guide treatment decisions and to select appropriate patients with unruptured intracranial aneurysms (IAs) for preventive treatment. High resolution four-dimensional magnetic resonance (4D MRI) flow imaging and 3D quantification of aneurysm morphology could offer insights and new imaging markers for aneurysm instability. In this cross-sectional study, we aim to identify 4D MRI flow imaging markers for aneurysm instability by relating hemodynamics in the aneurysm sac to 3D morphological proxy parameters for aneurysm instability. MATERIALS AND METHODS: In 35 patients with 37 unruptured IAs, a 3T MRA and a 7T 4D flow MRI scan was performed. Five hemodynamic parameters -peak-systolic (WSSMAX) and time-averaged wall shear stress (WSSMEAN), oscillatory shear index (OSI), mean velocity, and velocity pulsatility index (vPI)-were correlated to six 3D morphology proxy parameters of aneurysm instability -major axis length, volume, surface area (all three size parameters), flatness, shape index, and curvedness -by Pearson's correlation with 95% confidence intervals (CI). Scatterplots of hemodynamic parameters that correlated with IA size (major axis length) were created. RESULTS: WSSMAX and WSSMEAN correlated negatively with all three size parameters (strongest for WSSMEAN with volume (r = -0.70, 95% CI -0.83 to -0.49)) and OSI positively (strongest with major axis length (r = 0.87, 95% CI 0.76 to 0.93)). WSSMAX and WSSMEAN correlated positively with shape index (r = 0.61, 95% CI 0.36 to 0.78 and r = 0.49, 95% CI 0.20 to 0.70, respectively) and OSI negatively (r = 0.82, 95% CI -0.9 to -0.68). WSSMEAN and mean velocity correlated negatively with flatness (r = -0.35, 95% CI -0.61 to -0.029 and r = 0.33, 95% CI -0.59 to 0.007, respectively) and OSI positively (r = 0.54, 95% CI 0.26 to 0.74). vPI did not show any statistically significant correlation. CONCLUSIONS: Out of the five included hemodynamic parameters, WSSMAX, WSSMEAN, and OSI showed the strongest correlation with morphological 3D proxy parameters of aneurysm instability. Future studies should assess these promising new imaging marker parameters for predicting aneurysm instability in longitudinal cohorts of patients with IA.
引用
收藏
页码:1678 / 1684
页数:7
相关论文
共 50 条
  • [11] Utility of high-resolution MR imaging in the diagnosis of posterolateral rotary instability of the elbow
    Potter, HG
    Gusmer, PB
    Weiland, AJ
    Hotchkiss, RN
    Paletta, GA
    RADIOLOGY, 1996, 201 : 1262 - 1262
  • [12] Minimum wall shear stress points and their underlying intra-aneurysmal flow structures of unruptured cerebral aneurysms on 4D flow MRI
    Futami, Kazuya
    Misaki, Kouichi
    Uno, Takehiro
    Nambu, Iku
    Tsutsui, Taishi
    Kamide, Tomoya
    Nakada, Mitsutoshi
    JOURNAL OF NEURORADIOLOGY, 2023, 50 (03) : 302 - 308
  • [13] Clinical Application of 4D Flow MR Imaging to Pulmonary Hypertension
    Ota, Hideki
    Kamada, Hiroki
    Higuchi, Satoshi
    Takase, Kei
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 309 - 318
  • [14] Clinical Evaluation of Aortic Coarctation With 4D Flow MR Imaging
    Hope, Michael D.
    Meadows, Alison K.
    Hope, Thomas A.
    Ordovas, Karen G.
    Saloner, David
    Reddy, Gautham P.
    Alley, Marcus T.
    Higgins, Charles B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 711 - 718
  • [15] Clinical Application of 4D Flow MR Imaging for the Abdominal Aorta
    Takehara, Yasuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 354 - 364
  • [16] High-Resolution 3D MR Imaging of the Trochlear Nerve
    Choi, B. S.
    Kim, J. H.
    Jung, C.
    Hwang, J. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) : 1076 - 1079
  • [17] HIGH-RESOLUTION MR-IMAGING OF THE OPTIC-NERVE IN BENIGN INTRACRANIAL HYPERTENSION
    GASS, A
    BARKER, GJ
    MACMANUS, D
    MCDONALD, WI
    MOSELEY, IF
    MILLER, DH
    RADIOLOGY, 1995, 197 : 172 - 172
  • [18] Towards Cerebral Aneurysm Rupture Risk Prediction Using Quantitative Analysis by 4D Flow MRI: Intra-Aneurysmal Vortical Blood Flow and Association to Wall Shear Stress.
    Elbaz, Mohammed S.
    Aristova, Maria
    Ma, Liliana
    Vali, Alireza
    Bollache, Emilie
    Barker, Alex J.
    Hurley, Michael C.
    Potts, Matthew B.
    Jahromi, Babak S.
    Ansari, Sameer A.
    Markl, Michael
    Schnell, Susanne
    STROKE, 2019, 50
  • [19] HIGH-RESOLUTION 3-D IMAGING WITH MR OF THE KNEE - CORRELATION WITH ARTHROSCOPY
    HOGERLE, S
    SIEVERS, KW
    ALBRECHT, T
    LETSCH, R
    LOHR, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (04): : 341 - 348
  • [20] The association of intracranial atherosclerosis with cerebral small vessel disease imaging markers: a high-resolution magnetic resonance imaging study
    Zhu, Kang-Li
    Shang, Zi-Yang
    Liu, Bai-jun
    Wang, Ying
    Li, Jing
    Yang, Ben-Qiang
    Ntaios, George
    Chen, Hui-Sheng
    SCIENTIFIC REPORTS, 2023, 13 (01)