Pelvic target volume motion for cervical cancer with daily iterative cone beam computed tomography

被引:0
|
作者
Zeng, Zheng [1 ]
Zhang, Fuquan [2 ]
Yan, Junfang [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Dept Radiat Oncol, Peking Union Med Coll Hosp, Beijing, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Dept Radiat Oncol, Peking Union Med Coll Hosp, State Key Lab Complex Severe & Rare Dis, Beijing, Peoples R China
关键词
cervical cancer; inter-fractional motion; INTENSITY-MODULATED RADIOTHERAPY; ORGAN MOTION; RADIATION; IMRT; IGRT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
78
引用
收藏
页码:S139 / S141
页数:3
相关论文
共 50 条
  • [31] ANALYSIS OF PROSTATE BED MOTION USING DAILY CONE-BEAM COMPUTED TOMOGRAPHY DURING POSTPROSTATECTOMY RADIOTHERAPY
    Ost, Piet
    De Meerleer, Gert
    De Gersem, Werner
    Impens, Aline
    De Neve, Wilfried
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01): : 188 - 194
  • [32] Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins
    Patni, Nidhi
    Burela, Nagarjuna
    Pasricha, Rajesh
    Goyal, Jaishree
    Soni, Tej Prakash
    Kumar, T. Senthil
    Natarajan, T.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (01) : 131 - 136
  • [33] AUTOMATIC DETECTION OF PATIENT MOTION IN CONE-BEAM COMPUTED TOMOGRAPHY
    Ens, S.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1257 - 1260
  • [34] Projection matrix acquisition for cone-beam computed tomography iterative reconstruction
    Yang, Fuqiang
    Zhang, Dinghua
    Huang, Kuidong
    Shi, Wenlong
    Zhang, Caixin
    Gao, Zongzhao
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [35] Evaluation of male pelvic phantom for megavoltage cone-beam computed tomography
    Schaly, B.
    Varchena, V.
    Au, P.
    Pang, G.
    MEDICAL PHYSICS, 2006, 33 (07) : 2658 - 2658
  • [36] Clinical use of iterative 4D-cone beam computed tomography reconstructions to investigate respiratory tumor motion in lung cancer patients
    Schmidt, Mai L.
    Poulsen, Per R.
    Toftegaard, Jakob
    Hoffmann, Lone
    Hansen, David
    Sorensen, Thomas S.
    ACTA ONCOLOGICA, 2014, 53 (08) : 1107 - 1113
  • [37] Cone-Beam Computed Tomography for Planning Target Volume Margins and to Adapt Radiation Therapy Treatment for Locally Advanced Cervix Cancer
    Viani, G.
    Anderson, E.
    Salmon, H. A., Sr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E636 - E636
  • [38] Dose Verification of Four-Dimensional Cone-Beam Computed Tomography for Target Localization of Planned and Unplanned Target Motion
    Baley, C.
    Stathakis, S.
    Myers, P.
    Kirby, N.
    Rasmussen, K.
    Papanikolaou, N.
    Saenz, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E605 - E606
  • [39] A model for internal target volume definition based on 4D-cone beam computed tomography.
    Di Tommaso, M.
    Allajbej, A.
    Caravatta, L.
    Giancaterino, S.
    Di Girolamo, G.
    Falco, M. D.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S761 - S762
  • [40] Target volume motion during anal cancer IGRT using cone-beam CT
    Brooks, C.
    Bernier, L.
    Hansen, V.
    Tait, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S559 - S560