Intermittent Ex Vivo Lung Perfusion in a Porcine Model for Prolonged Lung Preservation

被引:3
|
作者
Sakanoue, Ichiro [1 ,2 ,3 ]
Okamoto, Toshihiro [1 ,2 ,4 ]
Ayyat, Kamal S. [1 ,2 ]
Yun, James J. [1 ,4 ]
Farver, Carol F. [5 ]
Fujioka, Hisashi [6 ]
Date, Hiroshi [3 ]
McCurry, Kenneth R. [1 ,2 ,4 ]
机构
[1] Cleveland Clin, Dept Thorac & Cardiovasc Surg, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Cleveland Clin, Lerner Res Inst, Dept Inflammat & Immunol, Cleveland, OH USA
[3] Kyoto Univ, Dept Thorac Surg, Kyoto, Japan
[4] Cleveland Clin, Transplant Ctr, Cleveland, OH USA
[5] Cleveland Clin, Dept Pathol, Cleveland, OH USA
[6] Case Western Reserve Univ, Cryo Electron Microscopy Core, Cleveland, OH USA
关键词
COLD PRESERVATION; DONOR LUNGS; TRANSPLANTATION; INJURY;
D O I
10.1097/TP.0000000000004802
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Ex vivo lung perfusion expands the lung transplant donor pool and extends preservation time beyond cold static preservation. We hypothesized that repeated regular ex vivo lung perfusion would better maintain lung grafts. Methods. Ten pig lungs were randomized into 2 groups. The control underwent 16 h of cold ischemic time and 2 h of cellular ex vivo lung perfusion. The intermittent ex vivo lung perfusion group underwent cold ischemic time for 4 h, ex vivo lung perfusion ( first) for 2 h, cold ischemic time for 10 h, and 2 h of ex vivo lung perfusion (second). Lungs were assessed, and transplant suitability was determined after 2 h of ex vivo lung perfusion. Results. The second ex vivo lung perfusion was significantly associated with better oxygenation, limited extravascular water, higher adenosine triphosphate, reduced intraalveolar edema, and well-preserved mitochondria compared with the control, despite proinflammatory cytokine elevation. No significant difference was observed in the first and second perfusion regarding oxygenation and adenosine triphosphate, whereas the second was associated with lower dynamic compliance and higher extravascular lung water than the first. Transplant suitability was 100% for the first and 60% for the second ex vivo lung perfusion, and 0% for the control. Conclusions. The second ex vivo lung perfusion had a slight deterioration in graft function compared to the first. Intermittent ex vivo lung perfusion created a better condition for lung grafts than cold static preservation, despite cytokine elevation. These results suggested that intermittent ex vivo lung perfusion may help prolong lung preservation.
引用
收藏
页码:669 / 678
页数:10
相关论文
共 50 条
  • [31] A porcine ex vivo paracorporeal model of lung transplantation
    Wright, NC
    Hopkinson, DN
    Shaw, TE
    Hooper, TL
    LABORATORY ANIMALS, 2000, 34 (01) : 56 - 62
  • [32] Porcine slaughterhouse lungs for ex vivo lung perfusion - a pilot project
    Kalka, Katharina
    Keldenich, Zoe
    Carstens, Henning
    Hilken, Gero
    Olbertz, Carolin
    Pizanis, Nikolaus
    Kamler, Markus
    Reiner, Gerald
    Koch, Achim
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2020, 12 (10): : 6455 - 6463
  • [33] Comparison of Ex Vivo Lung Perfusion, With or Without Albumin, With Static Cold Storage in a Rat Ex Vivo Lung Perfusion Model
    Mammana, Marco
    Zambello, Giovanni
    Pezzuto, Federica
    Faggi, Giulio
    Dedja, Arben
    Faccioli, Eleonora
    Schiavon, Marco
    Calabrese, Fiorella
    Rea, Federico
    Ex Vivo Lung Perfusion Working Grp, Ex Vivo Lung Perfusion Working
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2024, 22 (11)
  • [34] Extension of donor lung preservation with hypothermic storage after normothermic ex vivo lung perfusion
    Hsin, Michael Kuan Yew
    Iskender, Ilker
    Nakajima, Daisuke
    Chen, Manyin
    Kim, Hyunhee
    dos Santos, Pedro Reck
    Sakamoto, Jin
    Lee, Jingu
    Hashimoto, Kohei
    Harmantas, Constantine
    Hwang, David
    Waddell, Tom
    Liu, Mingyao
    Keshavjee, Shaf
    Cypel, Marcelo
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (01): : 130 - 136
  • [35] Lung transplant after prolonged ex vivo lung perfusion: predictors of allograft function in swine
    Spratt, John R.
    Mattison, Lars M.
    Iaizzo, Paul A.
    Meyer, Carolyn
    Brown, Roland Z.
    Iles, Tinen
    Panoskaltsis-Mortari, Angela
    Loor, Gabriel
    TRANSPLANT INTERNATIONAL, 2018, 31 (12) : 1405 - 1417
  • [36] A New Lung Preservation Technique through Bronchial Artery Perfusion on Ex-Vivo Lung
    Tanaka, Y.
    Shigemura, N.
    Noda, K.
    Bermudez, C. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S300 - S300
  • [37] In Vitro Analysis of RBC-Mediated Lung Injury in Prolonged Ex Vivo Lung Perfusion
    Spratt, J. R.
    Loor, G.
    Mattison, L. M.
    Meyer, C.
    Ehrhardt, M.
    Helms, H.
    Panoskaltsis-Mortari, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S311 - S311
  • [38] Targeting Circulating Leukocytes and Pyroptosis During Ex Vivo Lung Perfusion Improves Lung Preservation
    Noda, Kentaro
    Tane, Shinya
    Haam, Seok Jin
    D'Cunha, Jonathan
    Hayanga, Awori J.
    Luketich, James D.
    Shigemura, Norihisa
    TRANSPLANTATION, 2017, 101 (12) : 2841 - 2849
  • [39] Normothermic ex vivo lung perfusion outperforms conventional cold preservation in a deceased rat lung
    Wang, Weimin
    Qian, Jie
    Zhu, Minfang
    Wang, Yinghua
    Pan, Yan
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (02)
  • [40] EPC-K-1 is effective in lung preservation in an ex vivo rabbit lung perfusion model - Invited commentary
    Egan, TM
    ANNALS OF THORACIC SURGERY, 1997, 63 (04): : 959 - 959