Two-Segment High-Performance PV Grid-Connected Inverter

被引:1
|
作者
Liu, Ancheng [1 ]
Wang, Yipei [1 ]
Kwon, Taeho [2 ]
Park, Sung-Jun [1 ]
机构
[1] Chonnam Natl Univ, Dept Elect Engn, Gwangju 61186, South Korea
[2] Gyeonglim Co Ltd, Gyeongnam 52249, South Korea
关键词
Inverters; Power harmonic filters; Harmonic analysis; Voltage control; Active filters; Power system stability; Costs; Switches; Power filters; Frequency control; Harmonic suppression; photovoltaic grid-connected inverter; total harmonic distortion (THD); voltage sensitivity; 2ND-HARMONIC CURRENT REDUCTION; DC-DC CONVERTER; CURRENT SUPPRESSION; CURRENT CONTROLLER; POWER-FLOW; DEADTIME; HARMONICS; FILTER; COMPENSATION; IMPEDANCE;
D O I
10.1109/TPEL.2024.3480994
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In PV grid-connected applications, a grid-connected converter is usually used to connect with the grid to realize dc/ac conversion and power flow control. How to improve the quality of grid-connected current of power equipment so that the harmonic content injected into the grid is as little as possible has become a hot research topic in the field of PV grid-connected applications. By analyzing the causes of grid-connected harmonic currents during the grid-connection process, a two-segment high-performance grid-connected inverter topology is proposed. This structure makes the main inverter basically equal to the grid voltage through the simplest closed-loop control. Since the voltage sensitivity of the auxiliary inverter is low, utilizing the auxiliary inverter for the compensation of grid-connected voltage and grid-connected control of power flow will lead to an improvement in the quality of grid-connected current. A 3.3 kW grid-connected inverter system prototype is fabricated and tested, and the experimental results verify the stability and effectiveness of the theoretical analysis and the proposed control scheme.
引用
收藏
页码:2809 / 2821
页数:13
相关论文
共 50 条
  • [31] Study on High voltage Grid-Connected PV inverter based on Modular Multilevel Converter
    Xiao Xiang
    Xie Ning
    Zhou Yongyan
    Liu Xin
    Zhao Wei
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 1295 - 1299
  • [33] Synchronization technique of grid-connected PV inverter under unbalanced grid voltage
    Dang, Ke
    Zheng, Yuhao
    Yan, Gangui
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 (01): : 87 - 94
  • [34] Performance of PV Grid-Connected System Under Grid Failure
    Brahim, Mouhanned
    Belhadj, Jamel
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2013, 3 (04): : 754 - 762
  • [35] Finite Set MPC Control of Two Level Inverter for PV/Battery Grid-Connected System
    Habib, M.
    Ladjici, A. A.
    Bollin, E.
    2017 6TH INTERNATIONAL CONFERENCE ON SYSTEMS AND CONTROL (ICSC' 17), 2017, : 63 - 68
  • [36] Inverter deadtime modeling and its influence on grid-connected PV system
    逆变器死区建模及其对大型光伏并网系统的影响
    Mao, Mingxuan (mingxuan_mao@cqu.edu.cn), 1600, Science Press (41): : 161 - 168
  • [37] Performance Evaluation of a 17-Level Octuple Boost Inverter for a Grid-Connected PV System
    Chandan, Bikramaditya
    Pal, Pradipta Kumar
    Jana, Kartick Chandra
    IEEE ACCESS, 2024, 12 : 87284 - 87298
  • [38] A Novel Single-Phase Transformerless Grid-Connected PV Inverter
    Cunha, Arnaldo O., Jr.
    Bahia, Filipe A. C.
    Mello, Joao P. R. A.
    Tahim, Andre P. N.
    Costa, Fabiano F.
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [39] Site-dependent system performance and optimal inverter sizing of grid-connected PV systems
    Burger, B
    Rüther, R
    CONFERENCE RECORD OF THE THIRTY-FIRST IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 2005, 2005, : 1675 - 1678
  • [40] An integrated inverter with maximum power tracking for grid-connected PV systems
    Ho, BMT
    Chung, HSH
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) : 953 - 962