摘要
The paper deals with the step voltage calculation for the case of the simple grounding system (horizontal grounding electrode) injected with the fault current. Analysis is based on the thin wire antenna theory and corresponding frequency domain Pocklington integro-differential equation. The influence of a ground-air interface is taken into account via the Fresnel reflection coefficient (RC). The Pocklington integral equation is solved by the Galerkin Bubnov indirect boundary element procedure. After the current distribution along the grounding wire is calculated, electric potential at an arbitrary point on the ground surface is readily obtained by integrating the normal field component from infinity to the observation point. Step voltage is calculated as the voltage difference between two points 0.5m to 1m apart (average separation between human feet) along and perpendicular to the grounding electrode. Furthermore, step voltage is also calculated over the whole area in the vicinity of the grounding system taking into account direction of the steepest change of the potential and thus the worst case scenario.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Calculation of the Longitudinal Resistance of the Horizontal Elements of Large Grounding Devices.
    Yakobs, A.I.
    Petrov, P.I.
    Elektrichestvo, 1974, (01): : 13 - 18
  • [22] Calculation of performance of UHVDC grounding electrode under the consideration of the self-resistivity of electrode
    Wang, Jianwu
    Wen, Xishan
    Du, Zhongdong
    ICNC 2007: THIRD INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, VOL 5, PROCEEDINGS, 2007, : 425 - +
  • [23] STEP POTENTIALS NEAR A BURIED-WIRE GROUNDING ELECTRODE.
    Robertson, Neil C.
    Valentino, Anthony R.
    1979,
  • [24] Comparison of the antenna model and experimental analysis of an impulse impedance of the horizontal grounding electrode
    Sesnic, Silvestar
    Garma, Tonko
    Poljak, Dragan
    Tkachenko, Sergey V.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 125 : 159 - 163
  • [25] An analysis of conventional grounding impedance based on the impulsive current distribution of a horizontal electrode
    Choi, Jong-Hyuk
    Lee, Bok-Hee
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 85 : 30 - 37
  • [26] Influence of the Soil Ionization on the Transient Current Induced along the Horizontal Grounding Electrode
    Sesnic, Silvestar
    Poljak, Dragan
    Knezic, Goran
    2015 23RD INTERNATIONAL CONFERENCE ON SOFTWARE, TELECOMMUNICATIONS AND COMPUTER NETWORKS (SOFTCOM), 2015, : 64 - 68
  • [27] Direct time domain analytical solution for the transient impedance of the horizontal grounding electrode
    Sesnic, Silvestar
    Poljak, Dragan
    2018 2ND URSI ATLANTIC RADIO SCIENCE MEETING (AT-RASC), 2018,
  • [28] Using interpolation method to estimation step and touch voltage in grounding system
    Sikora, Roman
    Markiewicz, Przemyslaw
    Maczka, Mariusz
    Pawlowski, Stanislaw
    Plewako, Jolanta
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (02): : 263 - 266
  • [29] Calculation of step voltage in rectangular ground grid
    Lu, Zhiwei
    Chen, Cixuan
    Gaodianya Jishu/High Voltage Engineering, 1996, 22 (01): : 12 - 14
  • [30] ON CALCULATION OF INTENSE DESCENDING CONVECTION ABOVE A "COLD SPOT" ON A HORIZONTAL SURFACE
    Ingel, L. Kh.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2018, 91 (01) : 181 - 184