Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy

被引:1
|
作者
Koyanagi, Keita [1 ]
Shoji, Kippei [2 ]
Ueno, Akinori [1 ]
Sasaki, Tetsuo [2 ,3 ,4 ]
Otsuka, Makoto [1 ,4 ]
机构
[1] Earthtech Corp Ltd, 1780 Kamikouya, Yachiyo, Chiba 2760022, Japan
[2] Shizuoka Univ, Grad Sch Integrated Sci & Technol, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[3] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[4] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku,Cyuo ku, Hamamatsu 4328011, Japan
关键词
Fully flow-type continuous manufacturing sys-; tem; Process analytical technology; Real-time-monitoring; Near-infrared spectroscopy; Acetaminophen; Partial least squares regression analysis; Critical quality attribute; Critical process parameter; WET-GRANULATION; HIGH-SHEAR; QUALITY; IMPELLER; FUTURE; DESIGN; BATCH;
D O I
10.1016/j.jddst.2024.106240
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Granules for tableting were continuously manufactured using a fully flow-type continuous wet-granulation and drying (CGD) line system, "LaVortex (R)." The raw material powder containing standard excipients and 28.8 % acetaminophen was mixed with a binder liquid (pure water), continuously wet-granulated, and dried for 600 s under 20 different granulation/drying process conditions, and the process was monitored in real-time using nearinfrared (NIR) spectroscopy. Twenty granulation/drying process conditions, varying across three parameters, namely added binding water rate, agitation blades and container rotational rates, and hot drying air flow rate, were applied. Training datasets from NIR spectroscopy stably measured during the CGD process were used to construct calibration models to predict the various critical quality attributes (CQAs) of granules, such as residual moisture content, median particle size, angle of repose, and tablet hardness, using partial least squares regression (PLSR). Optimal calibration models were validated using the NIR spectroscopy test dataset. The actual granule CQA profiles evaluated using the NIR/PLSR method were almost constant up to 600 s at the end of production depending on the critical process parameters (CPPs), except for fluctuations in the initial process. These results indicate that tableting granules with various pharmaceutical properties could be obtained continuously depending on CQAs, such as the rate of water addition. Additionally, changes in CQAs could be continuously monitored by the NIR/PLSR method. Furthermore, CGD granules with various characteristic CQAs can be continuously manufactured by controlling CPPs, such as agitation blades and tube rotation rates in the agitating granulation process and drying air flow rate in the drying process under NIR spectroscopy.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Rapid near-infrared Raman spectroscopy system for real-time in vivo skin measurements
    Huang, ZW
    Zeng, HS
    Hamzavi, I
    McLean, DI
    Lui, H
    OPTICS LETTERS, 2001, 26 (22) : 1782 - 1784
  • [42] Real-time monitoring of the oligomerization reaction of bis(hydroxyethyl terephthalate) by near-infrared spectroscopy and chemometrics
    Amari, T
    Ozaki, Y
    APPLIED SPECTROSCOPY, 2002, 56 (03) : 350 - 356
  • [43] Process modeling and control applied to real-time monitoring of distillation processes by near-infrared spectroscopy
    de Oliveira, Rodrigo R.
    Pedroza, Ricardo H. P.
    Sousa, A. O.
    Lima, Kassio M. G.
    de Juan, Anna
    ANALYTICA CHIMICA ACTA, 2017, 985 : 41 - 53
  • [44] Elucidation of the Molecular Mechanism of Wet Granulation for Pharmaceutical Standard Formulations in a High-Speed Shear Mixer Using Near-Infrared Spectroscopy
    Omata, Ryo
    Hattori, Yusuke
    Sasaki, Tetsuo
    Sakamoto, Tomoaki
    Otsuka, Makoto
    PHARMACEUTICALS, 2020, 13 (09) : 1 - 16
  • [45] Assessment of Robustness for a Near-Infrared Concentration Model for Real-Time Release Testing in a Continuous Manufacturing Process
    Yleana M. Colón
    Jenny Vargas
    Eric Sánchez
    Gilfredo Navarro
    Rodolfo J. Romañach
    Journal of Pharmaceutical Innovation, 2017, 12 : 14 - 25
  • [46] Real-time imaging of muscle oxygenation using spatially resolved near-infrared spectroscopy
    Kek, KJ
    Samizo, M
    Kudo, N
    Yamamoto, K
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 30 - 31
  • [47] REAL-TIME MOISTURE MEASUREMENT ON A FORAGE HARVESTER USING NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    Digman, M. F.
    Shinners, K. J.
    TRANSACTIONS OF THE ASABE, 2008, 51 (05): : 1801 - 1810
  • [48] Assessment of Robustness for a Near-Infrared Concentration Model for Real-Time Release Testing in a Continuous Manufacturing Process
    Colon, Yleana M.
    Vargas, Jenny
    Sanchez, Eric
    Navarro, Gilfredo
    Romanach, Rodolfo J.
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2017, 12 (01) : 14 - 25
  • [49] Real-time moisture measurement on a forage harvester using near-infrared reflectance spectroscopy
    Digman, Matthew Francis
    Shinners, Kevin J.
    Transactions of the ASABE, 2008, 51 (05) : 1801 - 1810
  • [50] Real-time monitoring of the tablet-coating process by near-infrared spectroscopy - Effects of coating polymer concentrations on pharmaceutical properties of tablets
    Hattori, Yusuke
    Sugata, Misuzu
    Kamata, Hitoshi
    Nagata, Makoto
    Nagato, Takuya
    Hasegawa, Kouji
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2018, 46 : 111 - 121