共 50 条
Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis
被引:0
|作者:
Ferreira, Christian
[1
]
Ferreira, Marcio Yuri
[1
]
Bertani, Raphael
[2
]
Palavani, Lucca Biolcati
[3
]
Borges, Pedro G. L. B.
[4
]
Gunkan, Ahmet
[5
]
Mueller, Gean Carlo
[6
]
Maia, Henrique Garcia
[7
]
Semione, Gabriel
[8
]
Batista, Savio
[9
]
Lepine, Henrique Laurent
[2
]
Zumofen, Daniel
[10
]
Stark, Katherine
[1
]
Hanel, Ricardo A.
[11
]
Gordon, David
[12
]
Serulle, Yafell
[1
]
Langer, David
[1
]
机构:
[1] LENOX HILL HOSP, Dept Neurosurg, NEW YORK, NY USA
[2] Univ Sao Paulo, Dept Neurosurg, Sao Paulo, Brazil
[3] Max Planck Univ Ctr, Fac Med, Indaiatuba, Brazil
[4] Fundacao Tecn Educ Souza Marques, Rio De Janeiro, Brazil
[5] Faith Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkiye
[6] Univ Caxias Do Sul, Fac Med, Caxias Do Sul, Brazil
[7] Estacio Sa Univ Citta IDOMED, Fac Med, Gastao Senges Ave 125, BR-22631280 Rio De Janeiro, Brazil
[8] Univ West Santa Catarina, Joacaba, Brazil
[9] Univ Fed Rio de Janeiro, Rio De Janeiro, Brazil
[10] Maimonides Hosp, Div Neurosurg, Brooklyn, NY USA
[11] Baptist Med Ctr Jacksonville, Dept Neurosurg, Jacksonville, FL USA
[12] Northern Westchester & Phelps Hosp, Hofstra Northwell Sch Med, Westchester, NY USA
关键词:
Flow-diverter;
simulation;
flow-diverter sizing;
OCCLUSION;
DEVICE;
SIZE;
D O I:
10.1177/15910199251323006
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
Background Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment. Methods A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software. Results Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively. Conclusion VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.
引用
收藏
页数:9
相关论文