Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis

被引:0
|
作者
Ferreira, Christian [1 ]
Ferreira, Marcio Yuri [1 ]
Bertani, Raphael [2 ]
Palavani, Lucca Biolcati [3 ]
Borges, Pedro G. L. B. [4 ]
Gunkan, Ahmet [5 ]
Mueller, Gean Carlo [6 ]
Maia, Henrique Garcia [7 ]
Semione, Gabriel [8 ]
Batista, Savio [9 ]
Lepine, Henrique Laurent [2 ]
Zumofen, Daniel [10 ]
Stark, Katherine [1 ]
Hanel, Ricardo A. [11 ]
Gordon, David [12 ]
Serulle, Yafell [1 ]
Langer, David [1 ]
机构
[1] LENOX HILL HOSP, Dept Neurosurg, NEW YORK, NY USA
[2] Univ Sao Paulo, Dept Neurosurg, Sao Paulo, Brazil
[3] Max Planck Univ Ctr, Fac Med, Indaiatuba, Brazil
[4] Fundacao Tecn Educ Souza Marques, Rio De Janeiro, Brazil
[5] Faith Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkiye
[6] Univ Caxias Do Sul, Fac Med, Caxias Do Sul, Brazil
[7] Estacio Sa Univ Citta IDOMED, Fac Med, Gastao Senges Ave 125, BR-22631280 Rio De Janeiro, Brazil
[8] Univ West Santa Catarina, Joacaba, Brazil
[9] Univ Fed Rio de Janeiro, Rio De Janeiro, Brazil
[10] Maimonides Hosp, Div Neurosurg, Brooklyn, NY USA
[11] Baptist Med Ctr Jacksonville, Dept Neurosurg, Jacksonville, FL USA
[12] Northern Westchester & Phelps Hosp, Hofstra Northwell Sch Med, Westchester, NY USA
关键词
Flow-diverter; simulation; flow-diverter sizing; OCCLUSION; DEVICE; SIZE;
D O I
10.1177/15910199251323006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment. Methods A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software. Results Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively. Conclusion VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review
    Lv, Xianli
    Yang, Hongchao
    Liu, Peng
    Li, Youxiang
    NEURORADIOLOGY JOURNAL, 2016, 29 (01): : 66 - 71
  • [2] Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
    Arrese, Ignacio
    Sarabia, Rosario
    Pintado, Rebeca
    Delgado-Rodriguez, Miguel
    NEUROSURGERY, 2013, 73 (02) : 193 - 199
  • [3] Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis COMMENTS
    Briganti, Francesco
    Raymond, Jean
    Darsaut, Tim E.
    Byrne, James
    NEUROSURGERY, 2013, 73 (02) : 199 - 200
  • [4] Acutely Ruptured Intracranial Aneurysms Treated with Flow-Diverter Stents: A Systematic Review and Meta-Analysis
    Cagnazzo, F.
    di Carlo, D. T.
    Cappucci, M.
    Lefevre, P. -H.
    Costalat, V.
    Perrini, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (09) : 1669 - 1675
  • [5] Endovascular treatment of intracranial aneurysms with silk vista baby flow diverter: A systematic review and meta-analysis
    Hajikarimloo, Bardia
    Mohammadzadeh, Ibrahim
    Tos, Salem M.
    Hashemi, Rana
    Habibi, Mohammad Amin
    Hasanzade, Arman
    Bana, Sara
    Hooshmand, Mahdi
    Ghorbanpouryami, Fatemeh
    Najari, Dorsa
    Hezaveh, Ehsan Bahrami
    NEURORADIOLOGY JOURNAL, 2025,
  • [6] A systematic review and meta-analysis of Surpass flow diverter for the treatment of intracranial aneurysms
    William A. Florez-Perdomo
    Tariq Janjua
    Luis Rafael Moscote-Salazar
    Adesh Shrivastava
    Sumit Raj
    Amit Agrawal
    Egyptian Journal of Neurosurgery, 38
  • [7] A systematic review and meta-analysis of Surpass flow diverter for the treatment of intracranial aneurysms
    Florez-Perdomo, William A.
    Janjua, Tariq
    Moscote-Salazar, Luis Rafael
    Shrivastava, Adesh
    Raj, Sumit
    Agrawal, Amit
    EGYPTIAN JOURNAL OF NEUROSURGERY, 2023, 38 (01)
  • [8] The Silk flow-diverter stent for endovascular treatment of intracranial aneurysms
    Alghamdi, Faisal
    Morais, Ricardo
    Scillia, Pietro
    Lubicz, Boris
    EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (06) : 753 - 762
  • [9] Treatment of Middle Cerebral Artery Aneurysms with Flow-Diverter Stents: A Systematic Review and Meta-Analysis
    Cagnazzo, F.
    Mantilla, D.
    Lefevre, P-H.
    Dargazanli, C.
    Gascou, G.
    Costalat, V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) : 2289 - 2294
  • [10] Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review
    Briganti, Francesco
    Leone, Giuseppe
    Marseglia, Mariano
    Mariniello, Giuseppe
    Caranci, Ferdinando
    Brunetti, Arturo
    Maiuri, Francesco
    NEURORADIOLOGY JOURNAL, 2015, 28 (04): : 365 - 375