Humidity plays a vital role in our daily life and various agro-industrial productions, and humidity sensors have been widely applied in various fields. In this study, flexible, rapid-response, and directly readable composite humidity sensing films were fabricated, employing cellulose (water-soluble cellulose acetate (WSCA)) as moisture sensing layers and reduced graphene oxide (rGO) as resistive conductive layers. The rGO/WSCA composite film can be used as a new type of humidity-sensitive material for the development of humidity sensors. It has been confirmed that abundant hydroxyl groups in WSCA provided abundant adsorption sites and made the composite film highly sensitive to moisture. In addition, WSCA also be used as the dispersant, which could efficiently reduce lamellar accumulation of rGO during the reduction to form a tightly ordered brick-mortar microstructure of rGO/WSCA composite film. The ordered microstructure makes the composite films exhibit a satisfactory mechanical strength (339.5 MPa). Moreover, the rGO/WSCA film sensor could respond quickly within seconds and exhibited low hysteresis towards changes in RH from 23 % to 97 %, and the repeatable error was less than 2.3 % after 6 cycles. Further, the rGO/WSCA humidity sensor could monitor and recognize human respiratory frequency in different states, indicating its potential application in versatile noncontact humidity sensing fields.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Percolation effect of reduced graphene oxide (rGO) on ammonia sensing of rGO-SnO2 composite based sensor
    Feng, Qiuxia
    Li, Xiaogan
    Wang, Jing
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 1115 - 1126
  • [42] Graphene Oxide-Based Sensor for Human Breath Monitoring
    Vadera, Nikhil
    Dhanekar, Saakshi
    IEEE SENSORS LETTERS, 2023, 7 (12) : 1 - 4
  • [43] A highly sensitive flexible humidity sensor based on conductive tape and a carboxymethyl cellulose@graphene composite
    Wang, Haoxiang
    Tang, Chengli
    Xu, Jun
    RSC ADVANCES, 2023, 13 (40) : 27746 - 27755
  • [44] Flexible printed humidity sensor based on poly(3,4-ethylenedioxythiophene)/reduced graphene oxide/Au nanoparticles with high performance
    Zhang, Rongjin
    Peng, Bo
    Yuan, Yan
    COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 168 : 118 - 125
  • [45] Fully integrated wearable humidity sensor based on hydrothermally synthesized partially reduced graphene oxide
    Shojaee, M.
    Nasresfahani, Sh
    Dordane, M. K.
    Sheikhi, M. H.
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 : 448 - 456
  • [46] High-Performance Flexible Humidity Sensor Based on MoOX Nanoparticle Films for Monitoring Human Respiration and Non-Contact Sensing
    Xie, Bo
    You, Hai
    Qian, Haoyu
    Hao, Shengjie
    Li, Zenghui
    Qin, Yuyuan
    Wen, Hui-Min
    Xia, Shengjie
    Xiang, Yun
    Hu, Jun
    ACS APPLIED NANO MATERIALS, 2023, 6 (08) : 7011 - 7021
  • [47] Cellulose nanofibers/reduced graphene oxide flexible transparent conductive paper
    Gao, Kezheng
    Shao, Ziqiang
    Wu, Xue
    Wang, Xi
    Li, Jia
    Zhang, Yunhua
    Wang, Wenjun
    Wang, Feijun
    CARBOHYDRATE POLYMERS, 2013, 97 (01) : 243 - 251
  • [48] Research Progress of Graphene-Based Flexible Humidity Sensor
    Liang, Rongxuan
    Luo, Ansheng
    Zhang, Zhenbang
    Li, Zhantong
    Han, Chongyang
    Wu, Weibin
    SENSORS, 2020, 20 (19) : 1 - 17
  • [49] Development of a Fluorinated Graphene-Based Flexible Humidity Sensor
    Hajian, S.
    Zhang, X.
    Maddipatla, D.
    Narakathu, B. B.
    Hanson, A. J.
    Blair, R. G.
    Atashbarl, M. Z.
    PROCEEDINGS OF THE 2019 IEEE INTERNATIONAL CONFERENCE ON FLEXIBLE AND PRINTABLE SENSORS AND SYSTEMS (IEEE FLEPS 2019), 2019,
  • [50] Highly selective reduced graphene oxide (rGO) sensor based on a peptide aptamer receptor for detecting explosives
    Kyungjae Lee
    Yong Kyoung Yoo
    Myung-Sic Chae
    Kyo Seon Hwang
    Junwoo Lee
    Hyungsuk Kim
    Don Hur
    Jeong Hoon Lee
    Scientific Reports, 9