Seismic behavior of concrete-filled steel tubular flat columns with large steel ratios

被引:0
|
作者
Jiang, Qing [1 ,2 ]
Wang, Haijie [1 ]
Wang, Hanqin [3 ]
Shen, Wanyu [4 ]
Chong, Xun [1 ,2 ]
Feng, Yulong [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Peoples R China
[2] Anhui Civil Engn Struct & Mat Lab, Hefei 230009, Peoples R China
[3] Hefei Univ Technol, Sch Architecture & Art, Hefei 230601, Peoples R China
[4] Anhui Fuhuang Steel Struct Co Ltd, Technol Ctr, Chaohu 238076, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tubular flat column; Large steel ratio; Seismic behavior; Design method; BEAM-COLUMNS; TUBE; STRENGTH;
D O I
10.1016/j.jcsr.2025.109406
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled steel tubular columns (CFSTC) have received extensive attention in practical engineering applications. To meet the need for bearing capacity and address the problem of columns protruding from inner walls, concrete-filled steel tubular flat columns (CFSTFC) with a large steel ratio were proposed in this study. Compared with traditional rectangular CFSTC, the aspect ratio of CFSTFC is usually greater than 2.0. The effects of the aspect ratio and thickness of the steel tubular on the seismic performance of 12 CFSTFC were studied. The failure mode, hysteretic curve, skeleton curve, ductility, strength degradation, stiffness degradation and equivalent viscous damping coefficient of the specimen were analyzed in detail. The test results show that the CFSTFC still exhibited good seismic performance during the cracking process and that the ductility indices of all the specimens are between 2.24 and 2.79. The finite element model was established and verified on the basis of the test results. The parameters were analyzed, and the influences of the axial compression ratio and material strength were discussed. Finally, by comparison with the N-M interaction curves specified in the GB 50936, EC4 and AISC 360 codes, the accuracies of the different methods in the CFSTFC design were evaluated.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Experimental Research on Joints Behavior of Concrete-Filled Steel Tubular Columns
    He, Meili
    Yu, Hualong
    Cao, Yan
    Xia, Yongkang
    ADVANCED RESEARCH IN MATERIAL SCIENCE AND MECHANICAL ENGINEERING, PTS 1 AND 2, 2014, 446-447 : 1409 - +
  • [22] Investigation of cyclic behavior of partially concrete-filled steel tubular columns
    Gan, Dan
    Zhang, Yaojun
    Zhou, Xuhong
    Zhang, Xingjiang
    ENGINEERING STRUCTURES, 2024, 300
  • [23] Seismic Performance of Reinforced Concrete Beam to Concrete-filled Steel Tubular Columns Joints
    Qu, Hui
    Han, Lin-Hai
    Tao, Zhong
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 685 - +
  • [24] Experimental study on seismic behavior of connections for concrete-filled steel square tubular columns and steel-concrete composite beams
    Nie, JG
    Qin, K
    Xiao, Y
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 874 - 880
  • [25] Seismic behaviour of round-ended concrete-filled steel tubular columns
    Wang Z.
    Zheng Y.
    Lai Z.
    Shen W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (05): : 183 - 194
  • [26] Research On The Seismic Behavior Of Concrete-Filled Steel Tubular Column And Steel Beam Joint
    Yin, Yingzi
    Zhang, Yan
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2528 - 2532
  • [27] An experimental behaviour of concrete-filled steel tubular columns
    Zeghiche, J
    Chaoui, K
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (01) : 53 - 66
  • [28] A novel steel section for concrete-filled tubular columns
    Abedi, K.
    Ferdousi, A.
    Afshin, H.
    THIN-WALLED STRUCTURES, 2008, 46 (03) : 310 - 319
  • [29] State of the art of concrete-filled steel tubular columns
    Shams, M
    Saadeghvaziri, MA
    ACI STRUCTURAL JOURNAL, 1997, 94 (05) : 558 - 571
  • [30] Research on concrete-filled square steel tubular columns
    Zhang, ZG
    MULTI-PURPOSE HIGH-RISE TOWERS AND TALL BUILDINGS, 1997, : 157 - 168