An Automatic Magnetically Robotic System Using a Double-Loop Stable Control Method for Guidewire Steering

被引:1
|
作者
Xu, Sheng [1 ]
Chen, Binghan [1 ,2 ]
Li, Dong [1 ,2 ]
Fu, Shixiong [1 ,2 ]
Wu, Xinyu [1 ,2 ]
Du, Shiwei [3 ]
Xu, Tiantian [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol SIAT, Guangdong Prov Key Lab Robot & Intelligent Syst, Shenzhen 518055, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, Key Lab Biomed Imaging Sci & Syst, Shenzhen 518055, Peoples R China
[3] Shenzhen Univ, Dept Neurosurg, South China Hosp, Shenzhen 518111, Peoples R China
[4] Beijing Univ Technol, Engn Res Ctr Digital Community, Minist Educ, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Endovascular interventional surgery; magnetically actuated robot; sliding mode control (SMC); soft continuum robot; stability analysis; ACTIVE SUSPENSION SYSTEMS; PERFORMANCE;
D O I
10.1109/TMECH.2024.3477594
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Magnetically steerable endovascular guidewire robotic systems that are capable of automatic agile navigation have great potential for medical applications, such as endovascular interventional surgery. In addition, the guidewire robotic systems save doctors from radiation exposure. Some magnetic endovascular guidewires have been designed by researchers. However, they are primarily open-loop controlled. This article aims to investigate methods of closed-loop control of a magnetic endovascular guidewire. First, a new fully automatic magnetic guidewire steering system is developed, including a flexible industrial robot arm, and then, the guidewire steering problem is formulated and modeled with physical and mathematical analysis. Second, a double-loop magnetic control strategy, including the velocity (outer controller) and direction controllers (inner controller), is proposed using the exponential sliding mode control method. Meanwhile, the system stability is analyzed based on the Lyapunov theory and the stable controller parameter constraints are obtained. Simulation examples verify that the proposed controller has no overshot problem, which can significantly avoid vessel damage. Finally, the experimental examples demonstrate the effectiveness of our proposed method, which has significant value for practical surgical applications in near future.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Robotic Total Gastrectomy With Intracorporeal Robot-Sewn Anastomosis A Novel Approach Adopting the Double-Loop Reconstruction Method
    Parisi, Amilcare
    Ricci, Francesco
    Trastulli, Stefano
    Cirocchi, Roberto
    Gemini, Alessandro
    Grassi, Veronica
    Corsi, Alessia
    Renzi, Claudio
    De Santis, Francesco
    Petrina, Adolfo
    Pironi, Daniele
    D'Andrea, Vito
    Santoro, Alberto
    Desiderio, Jacopo
    MEDICINE, 2015, 94 (49)
  • [32] Research on design method of double-loop electric servo loading system with high-frequency band based on H∞ control strategy
    Shui, Yang
    Wei, Jianli
    Yan, Jie
    MEASUREMENT & CONTROL, 2020, 53 (9-10): : 1602 - 1615
  • [33] PID Control of Double-loop Speed Control System Based on Bacteria-Particle Swarm Hybrid Optimization Algorithm
    Cheng, Tao
    Lin, Weixing
    Li, Wenlei
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 1850 - 1854
  • [34] Vertical stability of ITER plasmas with 3D passive structures and a double-loop control system
    Portone, A
    Albanese, R
    Fresa, R
    Mattei, M
    Rubinacci, G
    Villone, F
    FUSION ENGINEERING AND DESIGN, 2005, 74 (1-4) : 537 - 542
  • [35] Guardrail collision avoidance for autonomous robotic vehicles by automatic steering control using an explicit force control algorithm
    Jung, S
    Lasky, TA
    Hsia, TC
    2005 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, VOLS 1 AND 2, 2005, : 265 - 270
  • [36] The Three-phase Unbalanced Overvoltage Suppression Method Based on Double-loop PI Control for Distribution Network
    Chen, Xiaogang
    Shen, Baiqiang
    Chen, Duohong
    Zeng, Xiangjun
    Zhou, Feng
    Li, Li
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [37] A new robot uncalibrated visual servoing control method with double-loop structure based on auto disturbance rejection
    Xin, Jing
    Liu, Ding
    Yang, Yan-Xi
    Xu, Qing-Kun
    Jiqiren/Robot, 2007, 29 (01): : 35 - 40
  • [38] Energy Management Method for Microgrid Based on Real-time Corrected Double-loop Control of Energy Storage
    Jia K.
    Lin Y.
    Chen Y.
    Bi T.
    Liu B.
    Jia, Ke (ke.jia@ncepu.edu.cn), 2018, Automation of Electric Power Systems Press (42): : 131 - 138
  • [39] Double-loop Control of Inverter with LCL Filter in Electrical Power System Based on Improved Instantaneous Symmetrical Component
    Ren, Yi
    Wan, Jianru
    Shi, Liguang
    Liu, Ran
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ELECTRICAL ENGINEERING, 2013, 676 : 265 - +
  • [40] Double-loop compensated active disturbance rejection control of electromechanical servo system based on composite disturbance observer
    Su, Zhenhao
    Shi, Wankai
    Duan, Jiandong
    Xu, Lang
    Zhou, Mingliang
    EXPERT SYSTEMS WITH APPLICATIONS, 2025, 266