Extremum Seeking Control of a Robotic Ankle-Foot Orthosis Targeting the Soleus Muscle Activation During Walking

被引:0
|
作者
Tulsky, Evan [1 ]
Rubino, Nicholas [1 ]
Carter, Jade [1 ]
Thompson, Aiko K. [2 ]
Duenas, Victor H. [1 ]
机构
[1] Syracuse Univ, Dept Mech & Aerosp Engn, Syracuse, NY 13244 USA
[2] Med Univ South Carolina, Charleston, SC 26425 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Extremum seeking control; ankle exoskeleton; nonlinear systems; FEEDBACK;
D O I
10.1109/CCTA60707.2024.10666517
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Stroke survivors experience muscle weakness and low weight-bearing capacity that impair their walking. The activation of the plantarflexor muscles is diminished following a stroke, which degrades propulsion and balance. Powered exoskeletons can improve gait capacity and restore impaired muscle activity. However, a technical barrier exists to generate systematic control methods to predictably and safely perturb the paretic leg using a wearable device to characterize the plantarflexors' muscle output for gait training. In this paper, a closed-loop robust controller is designed to impose an ankle joint rotation (i.e., a kinematic perturbation) in the mid-late stance phase to target the soleus muscle using a powered cable-driven ankle-foot orthosis. The goal is to generate soleus muscle activity increments throughout a gait experiment by applying ankle perturbations. This ability to modulate plan-tarflexor activity can be used in future conditioning studies to improve push-off and propulsion during walking. However, the optimal perturbation magnitude for each participant is unknown. Hence, online adaptation of the ankle perturbation is well-motivated to modulate the soleus response measured using surface electromyography (EMG). An extremum seeking controller (ESC) is implemented in real-time to compute the ankle perturbation magnitude (i.e., dorsiflexion angle) exploiting the soleus EMG response from the previous perturbed step to maximize the soleus response in the next perturbed step. A Lyapunov-based stability analysis is used to guarantee exponential kinematic tracking of the ankle perturbation objective.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 50 条
  • [31] Locomotor adaptation to a powered ankle-foot orthosis depends on control method
    Stephen M Cain
    Keith E Gordon
    Daniel P Ferris
    Journal of NeuroEngineering and Rehabilitation, 4
  • [32] Sensorless control system for assistive robotic ankle-foot
    Al Kouzbary, Mouaz
    Abu Osman, Noor Azuan
    Wahab, Ahmad Khairi Abdul
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2018, 15 (03):
  • [33] An improved powered ankle-foot orthosis using proportional myoelectric control
    Ferris, Daniel P.
    Gordon, Keith E.
    Sawicki, Gregory S.
    Peethambaran, Arnmanath
    GAIT & POSTURE, 2006, 23 (04) : 425 - 428
  • [34] COMPARISON OF HEMIPLEGIC PATIENTS WALKING UNBRACED, WITH AN ANKLE-FOOT ORTHOSIS, AND WITH THE AIR STIRRUP BRACE
    BURDETT, R
    BORELLO, D
    BLATCHLY, C
    POTTER, C
    PHYSICAL THERAPY, 1987, 67 (05): : 755 - 755
  • [35] COMPARISON OF WALKING ENERGY COST BETWEEN AN ANTERIOR AND A POSTERIOR ANKLE-FOOT ORTHOSIS IN PEOPLE WITH FOOT DROP
    Menotti, Federica
    Laudani, Luca
    Damiani, Antonello
    Orlando, Paola
    Macaluso, Andrea
    JOURNAL OF REHABILITATION MEDICINE, 2014, 46 (08) : 768 - 772
  • [36] Characterization of a Pneumatic Artificial Muscle for its application in an Active Ankle-Foot Orthosis
    Lescano, C.
    Herrera, C.
    Mirabal, R.
    Rodrigo, R.
    Rodrigo, S.
    19TH ARGENTINEAN BIOENGINEERING SOCIETY CONGRESS (SABI 2013), 2013, 477
  • [37] Does an ankle foot orthosis change the neural control of walking?
    Loadman, P. M.
    Murray, H.
    Villasenor-Herrera, A.
    Zehr, E.
    STROKE, 2012, 43 (11) : E148 - E148
  • [38] Force in the Achilles Tendon During Walking With Ankle Foot Orthosis
    Froberg, Asa
    Komi, Paavo
    Ishikawa, Masaki
    Movin, Tomas
    Arndt, Anton
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (06): : 1200 - 1207
  • [39] Design and Control of a Low-Cost EMG-Based Soft Robotic Ankle-Foot Orthosis for Foot Drop Rehabilitation
    Gudapati, Nitish
    Kumaran, Koushik
    Deepak, S., V
    Kanna, R. Mukesh
    Jinesh, R.
    Poddar, Himadri
    MACHINES, MECHANISM AND ROBOTICS, INACOMM 2019, 2022, : 1367 - 1382
  • [40] Development and reliability of a measure evaluating dynamic proprioception during walking with a robotized ankle-foot orthosis, and its relation to dynamic postural control
    Belley, Amelie Fournier
    Bouffard, Jason
    Brochu, Karine
    Mercier, Catherine
    Roy, Jean-Sebastien
    Bouyer, Laurent
    GAIT & POSTURE, 2016, 49 : 213 - 218