Optimizing Quantum Iterative Reconstruction for Ultra-high-resolution Photon-counting Computed Tomography of the Lung

被引:0
|
作者
Toth, Adrienn [1 ]
Chamberlin, Jordan H. [1 ]
Puthoff, Gregory [1 ]
Baruah, Dhiraj [1 ]
O'Doherty, Jim [1 ,2 ]
Maisuria, Dhruw [1 ]
Mcguire, Aaron M. [1 ]
Schoepf, U. Joseph [1 ]
Munden, Reginald F. [1 ]
Kabakus, Ismail M. [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC, Brazil
[2] Siemens Med Solut, Malvern, PA USA
关键词
photon-counting computed tomography; chest; ultra-high-resolution; image quality; iterative reconstruction; DETECTOR CT;
D O I
10.1097/RTI.0000000000000802
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:The aim of this study was to find the optimal strength level of QIR for ultra-high-resolution (UHR) PCCT of the lung. Materials and Methods:This retrospective study included 24 patients who had unenhanced chest CT with the novel UHR scan protocol on the PCCT scanner between March 24, 2023 and May 18, 2023. Two sets of reconstructions were made using different slice thicknesses: standard resolution (SR, 1 mm) and ultra-high-resolution (UHR, 0.2 mm), reconstructed with all strength levels of QIR (0 to 4). Attenuation of the lung parenchyma, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were assessed as objective criteria of image quality. Two fellowship-trained radiologists compared image quality and noise level, sharpness of the images, and the airway details using a 5-point Likert scale. Wilcoxon signed-rank test was used for statistical analysis of reader scores, and one-way repeated measures analysis of variance for comparing the objective image quality scores. Results:Objective image quality linearly improved with higher strength levels of QIR, reducing image noise by 66% from QIR-0 to QIR-4 (P<0.001). Subjective image noise was best for QIR-4 (P<0.001). Readers rated QIR-1 and QIR-2 best for SR, and QIR-2 and QIR-3 best for UHR in terms of subjective image sharpness and airway detail, without significant differences between them (P=0.48 and 0.56, respectively). Conclusions:Higher levels of QIR provided excellent objective image quality, but readers' preference was for intermediate levels. Considering all metrics, we recommend QIR-3 for ultra-high-resolution PCCT of the lung.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond
    Mese, Ismail
    Mese, Ceren Altintas
    Demirsoy, Ugur
    Anik, Yonca
    PEDIATRIC RADIOLOGY, 2024, 54 (01) : 1 - 11
  • [42] Investigation of bend loss in single mode fibers with ultra-high-resolution photon-counting optical time domain reflectometer
    Herrera, L. E. Y.
    Amaral, G. C.
    von der Weid, J. P.
    APPLIED OPTICS, 2016, 55 (05) : 1177 - 1182
  • [43] Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond
    Ismail Mese
    Ceren Altintas Mese
    Ugur Demirsoy
    Yonca Anik
    Pediatric Radiology, 2024, 54 : 1 - 11
  • [44] Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiography
    Hagar, Muhammad Taha
    Soschynski, Martin
    Saffar, Ruben
    Molina-Fuentes, Moises Felipe
    Weiss, Jakob
    Rau, Alexander
    Schuppert, Christopher
    Ruile, Philipp
    Faby, Sebastian
    Schibilsky, David
    von zur Muehlen, Constantin
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    EUROPEAN RADIOLOGY, 2024, 34 (07) : 4273 - 4283
  • [45] A Blooming correction technique for improved vasa vasorum detection using an ultra-high-resolution photon-counting detector CT
    Marsh, Jeffrey, Jr.
    Rajendran, Kishore
    Tao, Shengzhen
    Vercnocke, Andrew
    Anderson, Jill
    Leng, Shuai
    Ritman, Erik
    McCollough, Cynthia
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [46] Photon-Counting Computed Tomography in Atherosclerotic Plaque Characterization
    Cau, Riccardo
    Saba, Luca
    Balestrieri, Antonella
    Meloni, Antonella
    Mannelli, Lorenzo
    La Grutta, Ludovico
    Bossone, Eduardo
    Mantini, Cesare
    Politi, Carola
    Suri, Jasjit S.
    Cavaliere, Carlo
    Punzo, Bruna
    Maffei, Erica
    Cademartiri, Filippo
    DIAGNOSTICS, 2024, 14 (11)
  • [47] New contrast agents for photon-counting computed tomography
    Sawall, Stefan
    RADIOLOGIE, 2023, 63 (07): : 507 - 512
  • [48] CT technology: photon-counting detector computed tomography
    Layer, Yannik Christian
    Kravchenko, Dmitrij
    Dell, Tatjana
    Kuetting, Daniel
    RADIOLOGIE, 2023, 63 (07): : 497 - 506
  • [49] Photon-Counting Computed Tomography for the Diagnosis of Pulmonary Embolism
    Kumar, Pratik
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (01) : 100 - 101
  • [50] Photon-counting detector computed tomography in cardiac imaging
    Sharma, Simran P.
    Lemmens, Marie-Julie D. K.
    Smulders, Martijn W.
    Budde, Ricardo P. J.
    Hirsch, Alexander
    Mihl, Casper
    NETHERLANDS HEART JOURNAL, 2024, 32 (11) : 405 - 416