Optimizing Quantum Iterative Reconstruction for Ultra-high-resolution Photon-counting Computed Tomography of the Lung

被引:0
|
作者
Toth, Adrienn [1 ]
Chamberlin, Jordan H. [1 ]
Puthoff, Gregory [1 ]
Baruah, Dhiraj [1 ]
O'Doherty, Jim [1 ,2 ]
Maisuria, Dhruw [1 ]
Mcguire, Aaron M. [1 ]
Schoepf, U. Joseph [1 ]
Munden, Reginald F. [1 ]
Kabakus, Ismail M. [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC, Brazil
[2] Siemens Med Solut, Malvern, PA USA
关键词
photon-counting computed tomography; chest; ultra-high-resolution; image quality; iterative reconstruction; DETECTOR CT;
D O I
10.1097/RTI.0000000000000802
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:The aim of this study was to find the optimal strength level of QIR for ultra-high-resolution (UHR) PCCT of the lung. Materials and Methods:This retrospective study included 24 patients who had unenhanced chest CT with the novel UHR scan protocol on the PCCT scanner between March 24, 2023 and May 18, 2023. Two sets of reconstructions were made using different slice thicknesses: standard resolution (SR, 1 mm) and ultra-high-resolution (UHR, 0.2 mm), reconstructed with all strength levels of QIR (0 to 4). Attenuation of the lung parenchyma, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were assessed as objective criteria of image quality. Two fellowship-trained radiologists compared image quality and noise level, sharpness of the images, and the airway details using a 5-point Likert scale. Wilcoxon signed-rank test was used for statistical analysis of reader scores, and one-way repeated measures analysis of variance for comparing the objective image quality scores. Results:Objective image quality linearly improved with higher strength levels of QIR, reducing image noise by 66% from QIR-0 to QIR-4 (P<0.001). Subjective image noise was best for QIR-4 (P<0.001). Readers rated QIR-1 and QIR-2 best for SR, and QIR-2 and QIR-3 best for UHR in terms of subjective image sharpness and airway detail, without significant differences between them (P=0.48 and 0.56, respectively). Conclusions:Higher levels of QIR provided excellent objective image quality, but readers' preference was for intermediate levels. Considering all metrics, we recommend QIR-3 for ultra-high-resolution PCCT of the lung.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    DIAGNOSTICS, 2022, 12 (02)
  • [2] Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip
    Huflage, H.
    Grunz, J. -P
    Kunz, A. S.
    Patzer, T. S.
    Sauer, S. T.
    Christner, S. A.
    Petritsch, B.
    Erguen, S.
    Bley, T. A.
    Luetkens, K. S.
    RADIOGRAPHY, 2023, 29 (01) : 44 - 49
  • [3] Ultra-high-resolution photon-counting CT: "Plus Ultra" in lung imaging?
    Milos, Ruxandra-Iulia
    EUROPEAN RADIOLOGY, 2024, 34 (03) : 1893 - 1894
  • [4] Ultra-high-resolution photon-counting CT: “Plus Ultra” in lung imaging?
    Ruxandra-Iulia Milos
    European Radiology, 2024, 34 : 1893 - 1894
  • [5] Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography
    Huber, Nathan R.
    Ferrero, Andrea
    Rajendran, Kishore
    Baffour, Francis
    Glazebrook, Katrina N.
    Diehn, Felix E.
    Inoue, Akitoshi
    Fletcher, Joel G.
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (17):
  • [6] Ultra-high-resolution photon-counting CT of the lungs: a comparative study
    Van Ballaer, V.
    Dubbeldam, A.
    Cockmartin, L.
    Muscogiuri, E.
    Coolen, J.
    Coudyzer, W.
    De Wever, W.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [7] Ultra-high-resolution photon-counting detector computed tomography of the lungs: Phantom and clinical assessment of radiation dose and image quality
    Chamberlin, Jordan H.
    Smith, Carter D.
    Maisuria, Dhruw
    Parrish, Joe
    van Swol, Elizabeth
    Mah, Eugene
    Emrich, Tilman
    Schoepf, U. Joseph
    Varga-Szemes, Akos
    O'Doherty, Jim
    Munden, Reginald F.
    Tipnis, Sameer, V
    Baruah, Dhiraj
    Kabakus, Ismail M.
    CLINICAL IMAGING, 2023, 104
  • [8] Polychromatic Iterative Statistical Material Image Reconstruction for Photon-Counting Computed Tomography
    Weidinger, Thomas
    Buzug, Thorsten M.
    Flohr, Thomas
    Kappler, Steffen
    Stierstorfer, Karl
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2016, 2016
  • [9] Ultra-high-resolution photon-counting detector CT for visualization of the brachial plexus
    Nakashima, Masahiro
    Kawai, Tatsuya
    Matsumoto, Kazuhisa
    Kawaguchi, Takatsune
    Urano, Misugi
    Kitera, Nobuo
    Itoh, Toshihide
    Hiwatashi, Akio
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [10] Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs
    Graafen, Dirk
    Halfmann, Moritz C.
    Emrich, Tilman
    Yang, Yang
    Kreuter, Michael
    Dueber, Christoph
    Kloeckner, Roman
    Mueller, Lukas
    Jorg, Tobias
    DIAGNOSTICS, 2023, 13 (23)