Calibration of Wideband Current Transformers using a Precision Power Analyzer as Comparator

被引:0
|
作者
Munoz, Fabio [1 ]
Madhar, Saliha [1 ]
van den Brom, Helko [1 ]
Houtzager, Ernest [1 ]
Rietveld, Gert [1 ,2 ]
机构
[1] Natl Metrol Inst, VSL, Delft, Netherlands
[2] Univ Twente, Enschede, Netherlands
关键词
Current transformers; Wideband; Calibration; Precision power analyzers; Sampling current ratio bridge;
D O I
10.1109/CPEM61406.2024.10646121
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A measurement system is proposed for characterizing wideband current transformers (CTs) using a precision power analyzer as a sampling current ratio bridge. This approach simplifies the setup significantly with respect to conventional, primary measurement systems, with only a limited reduction in measurement uncertainty. Initial characterisation of the measurement system shows that it is able to achieve uncertainties of less than 50 ppm and 30 mu rad for CT ratio error and phase, displacement, respectively over the frequency range from 50 Hz to 5 kHz, provided a calibrated wideband reference CT is available with suitably low uncertainties. This makes the system ideal for use by NMIs and in industrial applications that do not need the ultimate accuracies achieved by primary CT calibration setups.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Multifunctional Wideband Digital Sampling System for the Calibration of Conventional Transformers and Electronic Transformers
    Pan, Yang
    Geng, Ji
    Zhou, Liren
    Lai, Lei
    Zhan, Guozhong
    Shao, Haiming
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 1
  • [22] HIGH-PRECISION CALIBRATION OF LONG GAUGE BLOCKS USING THE VACUUM WAVELENGTH COMPARATOR
    DARNEDDE, H
    METROLOGIA, 1992, 29 (05) : 349 - 359
  • [23] CALIBRATION, PRECISION AND ACCURACY OF A DUPONT THERMOMECHANICAL ANALYZER
    GASKILL, R
    BARRALL, EM
    THERMOCHIMICA ACTA, 1975, 12 (01) : 102 - 104
  • [24] Possibility of PD Calibration on Power Transformers Using UHF Probes
    Jahangir, H.
    Akbari, A.
    Werle, P.
    Szczechowski, J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (05) : 2968 - 2976
  • [25] Method for the Calibration of Cryogenic Current Comparator Ratios
    Lu, Yunfeng
    Zhao, Jianting
    He, Qing
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [27] Wideband digital phase comparator for high current shunts
    Pogliano, Umberto
    Trinchera, Bruno
    Serazio, Danilo
    METROLOGIA, 2012, 49 (03) : 349 - 358
  • [28] METHOD FOR THE ABSOLUTE CALIBRATION OF CURRENT TRANSFORMERS
    BETTS, PJ
    CLOTHIER, WK
    SMITH, HA
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1982, 129 (05): : 322 - 327
  • [29] Partial discharge location in power transformers using wideband RF detection
    Tang, Zhiguo
    Li, Chengrong
    Cheng, Xu
    Wang, Wei
    Li, Jinzhong
    Li, Jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (06) : 1193 - 1199
  • [30] A High-Precision Error Calibration Technique for Current Transformers under the Influence of DC Bias
    Dang, Sanlei
    Xiao, Yong
    Wang, Baoshuai
    Zhang, Dingqu
    Zhang, Bo
    Hu, Shanshan
    Song, Hongtian
    Xu, Chi
    Cai, Yiqin
    ENERGIES, 2023, 16 (24)