Neurophysiology Signal Codecs for the DICOM® Standard: Preliminary Results

被引:0
|
作者
Battaglia, Filippo [1 ]
Galanti, Mattia [2 ]
Gugliandolo, Giovanni [1 ]
Rampp, Stefan [3 ,4 ]
Remi, Jan [5 ]
Parashos, Alexandra [6 ]
Sharma, Sonali [6 ]
Bhatia, Sonal [6 ]
Dean, Brian C. [2 ]
Kutluay, Ekrem [7 ]
Campbell, Zeke [7 ]
Schmitt, Sarah [7 ]
Donato, Nicola [1 ]
Halford, Jonathan J. [7 ,8 ]
Campobello, Giuseppe [1 ]
机构
[1] Univ Messina, Dept Engn, Messina, Italy
[2] Clemson Univ, Sch Comp, Clemson, SC USA
[3] Univ Hosp Erlangen, Dept Neurosurg, Erlangen, Germany
[4] Univ Hosp Erlangen, Dept Neuroradiol, Erlangen, Germany
[5] Ludwig Maximilians Univ Munchen, Dept Neurol, Munich, Germany
[6] Med Univ South Carolina, Charleston, SC 29425 USA
[7] Ralph H Johnson VA Med Ctr, Charleston, SC USA
[8] Med Univ South Carolina, Dept Neurol, Charleston, SC 29425 USA
关键词
Neurophysiology signals; compression techniques; biomedical signal processing; NEAR-LOSSLESS COMPRESSION; NEURAL-NETWORK; EEG; ALGORITHM; SYSTEM;
D O I
10.1109/MEMEA60663.2024.10596834
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we report experimental results on compression of neurophysiology signals obtained as part of the standardization activities conducted by the Working Group 32 (WG-32) of the Digital Imaging and Communications in Medicine (DICOM). WG-32 focuses on extending the DICOM (R) standard for clinical neurophysiology data exchange. With this aim, several compression techniques specifically devised for neurophysiology signals, as well as audio codecs, have been investigated and compared using real-world datasets. Moreover, a web-based application, named EEGnet and developed specifically for viewing and annotating electroencephalography (EEG) data, has been exploited for determining the maximum distortion that can be tolerated on neurophysiology signals. Through the EEGnet framework, eight neurologists, affiliated to different universities and medical centers, identified signals where they observed a clinically-significant difference. As one of the main results of our study, we found that, in the case of EEG signals, a percentage root mean square difference (PRD) of 5% can be accepted by clinicians and experts. On the other hand, all experts agreed that distortion is unacceptable when the PRD is greater than 15%. Finally, surprisingly enough, experimental results showed that audio codecs provide performance levels that, in some cases, are comparable to those of state-of-the-art algorithms specifically devised for compression of EEG signals.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] NIST cesuim fountain frequency standard: Preliminary results
    Jefferts, SR
    Meekhof, DM
    Hollberg, LW
    Lee, D
    Drullinger, RE
    Walls, FL
    Nelson, C
    Levi, F
    Parker, TE
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, : 2 - 5
  • [32] Laparoscopic standard biliopancreatic diversion: Technique and preliminary results
    Scopinaro N.
    Marinari G.M.
    Camerini G.
    Obesity Surgery, 2002, 12 (3) : 362 - 365
  • [33] Laparoscopic standard biliopancreatic diversion: Technique and preliminary results
    Scopinaro, N
    Marinari, GM
    Camerini, G
    OBESITY SURGERY, 2002, 12 (02) : 241 - 244
  • [34] NIST cesium fountain frequency standard: Preliminary results
    Meekhof, DM
    Jefferts, SR
    Lee, D
    Nelson, C
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 130 - 131
  • [35] Clinical importance of the DICOM structured reporting standard
    Bidgood, WD
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (05): : 307 - 315
  • [36] Risks and Opportunities for Information Hiding in DICOM Standard
    Mileva, Aleksandra
    Caviglione, Luca
    Velinov, Aleksandar
    Wendzel, Steffen
    Dimitrova, Vesna
    ARES 2021: 16TH INTERNATIONAL CONFERENCE ON AVAILABILITY, RELIABILITY AND SECURITY, 2021,
  • [37] A CESIUM FOUNTAIN FREQUENCY STANDARD - PRELIMINARY-RESULTS
    CLAIRON, A
    LAURENT, P
    SANTARELLI, G
    GHEZALI, S
    LEA, SN
    BAHOURA, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 128 - 131
  • [38] Laparoscopic Standard Biliopancreatic Diversion: Technique and Preliminary Results
    Nicola Scopinaro
    Giuseppe M Marinari
    Giovanni Camerini
    Obesity Surgery, 2002, 12 : 241 - 244
  • [39] Adding Constraint Tables to the DMN Standard: Preliminary Results
    Deryck, Marjolein
    Aerts, Bram
    Vennekens, Joost
    RULES AND REASONING (RULEML+RR 2019), 2019, 11784 : 171 - 179
  • [40] Adopting the DICOM standard for medical infrared images
    Schaefer, Gerald
    Huguet, Jordi
    Zhu, Shao Ying
    Plassirtann, Peter
    Ring, Francis
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4081 - +