The influence of 3-dimensional printing layer thickness on model accuracy and the perceived fit of thermoformed retainers

被引:0
|
作者
Elshebiny, Tarek [1 ]
Canepa, Ian [1 ]
Kasper, F. Kurtis [2 ]
Tsolakis, Ioannis A. [1 ,3 ]
Matthaios, Stefanos [1 ]
Palomo, Juan Martin [1 ]
机构
[1] Case Western Reserve Univ, Dept Orthodont, Cleveland, OH USA
[2] Univ Texas, Dept Orthodont, Houston, TX USA
[3] Aristotle Univ Thessaloniki, Fac Hlth Sci, Sch Dent, Dept Orthodont, Thessaloniki, Greece
关键词
HEIGHT; TECHNOLOGY;
D O I
10.1016/j.ajodo.2024.11.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to investigate the accuracy of dental model printing using 2 different layer height settings and how these settings affect the fabrication of thermoformed retainers. Methods: Subjects were recruited from the Department of Orthodontics at Case Western Reserve University and scanned according to specific selection criteria. A total of 30 stereolithography files were produced and used as reference files. The stereolithography files were printed at the recommended layer height of 100 mu m and 170 mu m with a Sprint Ray Pro 95 3-dimensional (3D) printer (Sprint Ray, Los Angeles, Calif). All printed models were scanned using the same iTero intraoral scanner (Align Technology, San Jose, Calif) as was used for the initial intraoral scan as well. The accuracy of the printed models was based on the evaluation of root mean square values resulting from 3D superimpositions. Afterward, vacuum-formed retainers were fabricated. The vacuum-formed retainers were evaluated by the patient and an American Board of Orthodontics-certified orthodontist. Results: No difference was observed in the maxillary arch (P = 0.85) and the mandibular arch accuracy (P = 0.08) by assessing the root mean square values. No difference was observed in the doctor retainer score of the maxillary retainers (P = 0.37) and the mandibular retainers (P = 0.77). There was no difference in the patient retainer score of the maxillary (P = 0.08) and the mandibular retainers (P = 0.22) when comparing retainers. Conversely, less printing time was observed when printing the models with 170 mu m compared with 100 mu m (P <0.001). Conclusions: The accuracy of a dental model printed with a Sprint Ray Pro 95 3D printer was not affected by the 100 or 170 mu m layer height. Orthodontists and patients did not detect a statistically significant difference in retainer fit.
引用
收藏
页数:12
相关论文
共 50 条
  • [42] Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study
    Xie, Ping
    Hu, Zizhong
    Zhang, Xiaojun
    Li, Xinhua
    Gao, Zhishan
    Yuan, Dongqing
    Liu, Qinghuai
    PLOS ONE, 2014, 9 (11):
  • [43] Evaluation of the Accuracy of 3-Dimensional Ultrasonography of the Kidney Using an In Vitro Renal Model
    John, Babbin S.
    Rowland, David
    Patel, Uday
    Pilcher, James
    Anson, Ken
    Nassiri, Dariush
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (02) : 155 - 162
  • [44] 3-DIMENSIONAL THIN-LAYER CHROMATOGRAPHY ON A SINGLE PLATE WITH CONSTANT THICKNESS AND UNMODIFIED ADSORBENT
    DEOSSO, FJ
    JOURNAL OF CHROMATOGRAPHY, 1971, 60 (02): : 270 - &
  • [45] Mandibular reconstruction using plates prebent to fit rapid prototyping 3-dimensional printing models ameliorates contour deformity
    Azuma, Masaki
    Yanagawa, Toru
    Ishibashi-Kanno, Naomi
    Uchida, Fumihiko
    Ito, Takaaki
    Yamagata, Kenji
    Hasegawa, Shogo
    Sasaki, Kaoru
    Adachi, Koji
    Tabuchi, Katsuhiko
    Sekido, Mitsuru
    Bukawa, Hiroki
    HEAD & FACE MEDICINE, 2014, 10 : 45
  • [46] Mandibular reconstruction using plates prebent to fit rapid prototyping 3-dimensional printing models ameliorates contour deformity
    Masaki Azuma
    Toru Yanagawa
    Naomi Ishibashi–Kanno
    Fumihiko Uchida
    Takaaki Ito
    Kenji Yamagata
    Shogo Hasegawa
    Kaoru Sasaki
    Koji Adachi
    Katsuhiko Tabuchi
    Mitsuru Sekido
    Hiroki Bukawa
    Head & Face Medicine, 10
  • [47] Seeing Both the Forest and the Trees: Where Does 3-Dimensional Printing Fit in Pediatric Living Donor Liver Transplantation?
    Mazariegos, George V.
    Humar, Abhinav
    LIVER TRANSPLANTATION, 2019, 25 (06) : 825 - 826
  • [48] Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models
    Favero, Christian S.
    English, Jeryl D.
    Cozad, Benjamin E.
    Wirthlin, John O.
    Short, Megan M.
    Kasper, F. Kurtis
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (04) : 557 - 565
  • [49] Accuracy of trial complete dentures fabricated by using fused deposition modeling 3-dimensional printing: An in vitro study
    Lo Russo, Lucio
    Lo Muzio, Eleonora
    Troiano, Giuseppe
    Salamini, Angelo
    Zhurakivska, Khrystyna
    Guida, Laura
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 908 - 912
  • [50] 3-DIMENSIONAL FLUX PHASES OF THE T-J MODEL IN A LAYER STRUCTURE
    MORI, H
    PHYSICAL REVIEW B, 1991, 44 (06): : 2762 - 2766