Comparative evaluation of OCT with OCTA changes at the optic disc and macula in glaucoma suspect and early glaucoma

被引:0
|
作者
Angmo, Dewang [1 ]
Kapoor, Anirudh [1 ]
Warjri, Gazella B. [1 ]
Azad, Shorya Vardhan [2 ]
Chawla, Rohan [2 ]
Gupta, Viney [1 ]
Dada, Tanuj [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res Facil & Clin Serv, New Delhi, India
[2] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Vitreo Retina Uvea ROP Serv, New Delhi, India
关键词
Macular vessel density; OCT; OCTA; optical coherence tomography; optical coherence tomography angiography; optic nerve head flux index; optic nerve head perfusion; COHERENCE TOMOGRAPHY ANGIOGRAPHY; FIBER LAYER THICKNESS; PREPERIMETRIC GLAUCOMA; AUTOMATED PERIMETRY; DIAGNOSTIC ABILITY; CAPILLARY DENSITY; VESSEL DENSITY; PERIPAPILLARY; EYES; ATROPHY;
D O I
10.4103/IJO.IJO_2575_23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the diagnostic ability of macular ganglion cell inner plexiform layer (mGCIPL) and peripapillary retinal nerve fiber layer (pRNFL) thickness on optical coherence tomography (OCT) and macular and peripapillary perfusion changes using OCT angiography (OCTA) in glaucoma suspect and early primary open angle glaucoma (POAG). Methods: Ninety patients (30 normal, 30 glaucoma suspects, and 30 early POAG) were recruited in this cross-sectional, prospective study. The average thickness of mGCIPL and pRNFL on spectral domain-OCT and macular vessel density (VD), optic nerve head (ONH) perfusion, and ONH flux index (FI) on OCTA were evaluated for early diagnosis of glaucoma. Results: Macular VD, ONH perfusion, and ONH FI were significantly reduced in early POAG eyes compared to normal. The best correlation was observed between ONH FI and the average RNFL in both glaucoma suspects (r = 0.47, P < 0.01) and early POAG patients (r = 0.53, P < 0.01). Out of all the measured OCTA parameters, only ONH perfusion was significantly lower in glaucomatous eyes compared to glaucoma suspects (P < 0.001). Average GCIPL (0.82) and macular VD (0.76) had the highest area under the receiver operating characteristic (AUROC) curve value among all the OCT and OCTA parameters, respectively, for differentiating glaucoma suspects from controls. Rim area (0.92) and ONH FI (0.81) had the highest AUROC value among all the OCT and OCTA parameters for differentiating early POAG patients from controls. Conclusion: OCTA vascular parameters had a good correlation with structural damage both at the disc and the macula. OCT parameters were superior to OCTA parameters for diagnosis of glaucoma, although OCTA parameters are deranged very early in the disease.
引用
收藏
页码:S260 / S266
页数:7
相关论文
共 50 条
  • [41] A new OCT 3 macula map for detection of glaucoma
    Vessani, RM
    Ozden, RG
    Huang, X
    Makornwattana, M
    Zafar, S
    Tello, C
    Liebmann, J
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U235 - U235
  • [42] OCT Angiography of the Glaucoma Optic Nerve
    Lommatzsch, C.
    Koch, J. M.
    Claussnitzer, H.
    Heinz, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (02) : 205 - 211
  • [43] The Effect of Cataract and Cataract Extraction on Cirrus OCT Measurements in Glaucoma and Glaucoma Suspect Patients
    Farley, Nathan
    Shukairy, Aman
    DeCaluwe, Brandon
    Hughes, Bret
    Nagori, Saya
    Juzych, Mark S.
    Goyal, Anju
    Kim, Chaesik
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [44] Early detection of glaucoma using optic disc and optic cup segmentation: A survey
    Janani, R.
    Rajamohana, S. P.
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 2763 - 2769
  • [45] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Yip, Vivien C. H.
    Wong, Hon Tym
    Yong, Vernon K. Y.
    Lim, Boon Ang
    Hee, Owen K.
    Cheng, Jun
    Fu, Huazhu
    Lim, Chingwei
    Tay, Elton L. T.
    Loo-Valdez, Roselyn G.
    Teo, Hwei Yee
    Lim, Angela P. H.
    Yip, Leonard W. L.
    JOURNAL OF GLAUCOMA, 2019, 28 (01) : 80 - 87
  • [46] Optical Coherence Tomography Angiography of Optic Disc and Macula Vessel Density in Glaucoma and Healthy Eyes
    Jain, Kanika
    Pegu, Julie
    Bhoot, Madhu
    Dubey, Suneeta
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : E131 - E132
  • [47] Telematic assisted optic disc evaluation in patients with suspected glaucoma
    Scibor, M
    Lämmer, R
    Michelson, G
    Harazny, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U12 - U12
  • [48] Klinische Papillenbeurteilung bei GlaukomClinical evaluation of the optic disc in glaucoma
    R. Greslechner
    D. Spiegel
    Der Ophthalmologe, 2016, 113 : 816 - 823
  • [49] Comparative optic disc analysis in normal pressure glaucoma, primary open angle glaucoma and ocular hypertension
    Tezel, G
    Kass, MA
    Kolker, AE
    Wax, MB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1894 - 1894
  • [50] Comparison of Superficial versus Deep Macula Vessel Density Measurements in Normal, Glaucoma Suspect, and Glaucoma Eyes
    Manalastas, Patricia Isabel C.
    Moghimi, Sasan
    Zangwill, Linda M.
    Christopher, Mark
    Hasenstab, Kyle
    Penteado, Rafaella
    Hou, Huiyuan
    Shoji, Takuhei
    Ghahari, Elham
    Li, Andrew J.
    Khoa Nguyen
    Villatoro, George
    Yarmohammadi, Adeleh
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)